<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Displaying new levels in references</title><link>https://communities.bentley.com/products/microstation/w/askinga/681/displaying-new-levels-in-references</link><description>Articles previously found in the &amp;quot;AskInga&amp;quot; Community.</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Displaying new levels in references</title><link>https://communities.bentley.com/products/microstation/w/askinga/681/displaying-new-levels-in-references</link><pubDate>Thu, 10 Jun 2010 16:05:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9d318910-1012-4d6c-bd77-c8fef519d07d</guid><dc:creator>Inga Morozoff</dc:creator><comments>https://communities.bentley.com/products/microstation/w/askinga/681/displaying-new-levels-in-references#comments</comments><description>Current Revision posted to [Archived] AskInga Wiki by Inga Morozoff on 6/10/2010 4:05:41 PM&lt;br /&gt;
&lt;p&gt;&lt;a href="/Communities/Other_Communities/AskInga/default.aspx"&gt;&lt;img height="76" width="230" src="/askIngaPics/askingalogo.gif" alt="AskInga logo" border="0" title="AskInga" /&gt;&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Tip Date: &lt;/strong&gt;&lt;em&gt;Nov 30, 2006&lt;/em&gt; &lt;/p&gt;
&lt;table cellpadding="0" cellspacing="0" border="0" style="width:95%;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="left" valign="top"&gt;&lt;strong&gt;Displaying new levels in references&lt;/strong&gt;&lt;br /&gt;&lt;/td&gt;
&lt;td align="right" valign="top"&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td align="left" colspan="2" valign="top"&gt;In MicroStation V8 XM Edition you can control the display of new levels in a referece on a &lt;em&gt;per file&lt;/em&gt; basis. When attaching a reference, take a close look at the Attachment Settings dialog and note the following options for &lt;em&gt;New Level Display&lt;/em&gt;:&lt;br /&gt;&lt;br /&gt;&lt;em&gt;Use MS_REF_NEWLEVELDISPLAY configuration variable&lt;/em&gt; (Default Setting) New levels in the reference are displayed according to the setting for the MS_REF_NEWLEVELDISPLAY configuration variable. If this variable is set, MicroStation displays newly created levels in references. By default, when new levels are created in a model that is referenced by another model, the new levels are not displayed when the referencing model is opened. Newly created models are considered until &amp;quot;Save settings&amp;quot; is performed. This functionality only works when both the master file and referenced files are in the V8 file format. &lt;br /&gt;&lt;br /&gt;&lt;em&gt;Always&lt;/em&gt; New levels in the reference are always displayed.&lt;br /&gt;&lt;br /&gt;&lt;em&gt;Never&lt;/em&gt; New levels in the reference are never displayed.&lt;br /&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td align="left" colspan="2" valign="top"&gt;&lt;br /&gt;&lt;img src="/askIngaPics/tip683.gif" align="left" border="0" alt="" /&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;AskInga Tip #683&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: tip, Askinga, Levels&lt;/div&gt;
</description></item><item><title>Displaying New Levels In References</title><link>https://communities.bentley.com/products/microstation/w/askinga/681/displaying-new-levels-in-references/revision/1</link><pubDate>Tue, 17 Jun 2008 20:57:56 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9d318910-1012-4d6c-bd77-c8fef519d07d</guid><dc:creator>Nicholas Fuschino</dc:creator><comments>https://communities.bentley.com/products/microstation/w/askinga/681/displaying-new-levels-in-references#comments</comments><description>Revision 1 posted to [Archived] AskInga Wiki by Nicholas Fuschino on 6/17/2008 8:57:56 PM&lt;br /&gt;
&lt;p&gt;
&lt;a href="/Communities/Other_Communities/AskInga/default.aspx"&gt;&lt;img src="/askIngaPics/askingalogo.gif" border="0" alt="AskInga logo" title="AskInga" width="230" height="76" /&gt;&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;strong&gt;Original Tip Date: &lt;/strong&gt;&lt;em&gt;Nov 30, 2006&lt;/em&gt;
&lt;/p&gt;
&lt;table border="0" cellspacing="0" cellpadding="0" width="95%"&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td align="left" valign="top"&gt;&lt;strong&gt;Displaying new levels in references&lt;/strong&gt;&lt;br /&gt;
			&lt;/td&gt;
			&lt;td align="right" valign="top"&gt;&amp;nbsp;&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td colspan="2" align="left" valign="top"&gt;In MicroStation V8 XM Edition you can control the display of new levels in a referece on a &lt;em&gt;per file&lt;/em&gt; basis. When attaching a reference, take a close look at the Attachment Settings dialog and note the following options for &lt;em&gt;New Level Display&lt;/em&gt;:&lt;br /&gt;
			&lt;br /&gt;
			&lt;em&gt;Use MS_REF_NEWLEVELDISPLAY configuration variable&lt;/em&gt; (Default Setting) New levels in the reference are displayed according to the setting for the MS_REF_NEWLEVELDISPLAY configuration variable. If this variable is set, MicroStation displays newly created levels in references. By default, when new levels are created in a model that is referenced by another model, the new levels are not displayed when the referencing model is opened. Newly created models are considered until &amp;quot;Save settings&amp;quot; is performed. This functionality only works when both the master file and referenced files are in the V8 file format. &lt;br /&gt;
			&lt;br /&gt;
			&lt;em&gt;Always&lt;/em&gt; New levels in the reference are always displayed.&lt;br /&gt;
			&lt;br /&gt;
			&lt;em&gt;Never&lt;/em&gt; New levels in the reference are never displayed.&lt;br /&gt;
			&lt;br /&gt;
			&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td colspan="2" align="left" valign="top"&gt;&lt;br /&gt;
			&lt;img src="/askIngaPics/tip683.gif" border="0" align="left" /&gt;&lt;br /&gt;
			&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;
AskInga Tip #683 
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Askinga, Levels, tip&lt;/div&gt;
</description></item></channel></rss>