MicroStation Wiki (Deutsch) MicroStation CONNECT Edition Konfigurations-Variablen (deutsch)
    • Sign in
    • MicroStation - Wiki (Deutsch)
    • +AECOsim Building Designer
    • +Bentley LEARN
    • +Bentley LumenRT
    • +Bentley Navigator
    • +Bentley View
    • +CONNECTION Client
    • +ContextCapture
    • -MicroStation
      • +Animation - MicroStation
      • +Anpassung der Benutzeroberfläche - MicroStation
      • +Ansicht - MicroStation
      • +Archivieren/Sichern - MicroStation
      • +Austausch - MicroStation
      • +Auswahl - MicroStation
      • +Basisgeometrie - MicroStation
      • Behobene Probleme in MicroStation CONNECT Edition Update 13, 10.13.00.48
      • +Bemaßungen - MicroStation
      • +Bemusterung - MicroStation
      • +Benutzerdefinierte Stricharten - MicroStation
      • +Blattaufbau - MicroStation
      • +Dateizugriff - MicroStation
      • +Detailsymbole - MicroStation
      • +DGN - MicroStation
      • +Dokumentation und Hilfe - MicroStation
      • +Drucken - MicroStation
      • +DWG - MicroStation
      • +Ebenen - MicroStation
      • +Eigenschaften - MicroStation
      • +Einheiten - MicroStation
      • +FAQ - MicroStation
      • +Feature-basierte Volumenelement-Modellierung - MicroStation
      • +Grafikanzeige - MicroStation
      • +Graphics Display - MicroStation
      • +Gruppen - MicroStation
      • +GUI - MicroStation
      • +Hardware/Eingabegeräte - MicroStation
      • +i.Models - MicroStation
      • +Installation - MicroStation
      • +Interferenz - MicroStation
      • -Konfiguration - MicroStation
        • -Allgemein - Konfiguration - MicroStation
          • AccuDraw Schnelltasten shortcut.txt
          • Andere Konfigurationsvariablen referenzieren
          • Arbeitsbereichsoptionen im MicroStation Manager deaktivieren
          • Automatisch einen Tastatureingabebefehl oder Basic Makro beim Öffnen von Dateien ausführen
          • Das Ausgabe Verzeichnis für die msdebug.txt Datei festlegen
          • Deaktivieren der ProjectWise-Integration beim Start von MicroStation vom Desktop aus
          • Der ganze Speicher wird nicht verwendet – wie kann die Performance verbessert werden?
          • Die Zeichnungshistorie wird nicht dargestellt, obwohl MS_FILEHISTORY=1 eingesetzt wurde.
          • ESC-Taste der Tastatur auf einer Maustaste simulieren
          • Fehlermeldung beim Starten von MicroStation wegen UCF-Datei
          • Konfiguration auf ein übergeordnetes Verzeichnis
          • Konfigurationsvariable über Tastatureingabebefehl setzen
          • Konfigurationsvariablen Operatoren
          • Konfigurationsvariablen verstehen
          • Lokale MicroStation Einstellungen umleiten
          • MicroStation bei Nichtverwendung / Leerlauf automatisch schließen / beenden
          • MicroStation CONNECT Edition Konfigurations-Variablen (deutsch)
          • MicroStation hängt beim Start, nachdem Windows 10 Update (Spring Creator) installiert wurde
          • MicroStation V8i Variablen (deutsch)
          • Präprozessor-Direktiven zur Verarbeitung von Konfigurationsdateien
          • UCF-Dateien automatisch in bestimmten Pfad sichern
          • Unable to create a CSV collection from the design file (deutsch)
          • Unterschied zwischen den verschiedenen Präprozessor-Direktiven
          • Warum ist die Konfigurationsvariable MS_FILEHISTORY gesperrt und mit dem Wert 0 definiert?
          • Was passiert, wenn MicroStation gestartet wird?
          • Welche Konfigurationsänderungen wurden in der MicroStation CONNECT Edition vorgenommen?
          • Wie man die Benutzervoreinstellungen zurücksetzt und MicroStation Temp Dateien löscht
          • Wie man die Meldung „MicroStation not responding“ deaktiviert
          • Wie man schnell eine Debug-Datei (msdebug.txt) erzeugt
          • Wofür ist Gestenzuweisung?
        • +Arbeitsbereiche - Konfiguration - MicroStation
        • +Benutzervoreinstellungen - Konfiguration - MicroStation
        • +DGN-Einstellungen - Konfiguration - MicroStation
        • Konfigurationsvariablen per Tastatureingabe anlegen oder verändern
        • +WorkSet - Konfiguration - MicroStation
      • +Koordinatensysteme - MicroStation
      • +Kurven - MicroStation
      • Levels - MicroStation
      • +Manipulation - MicroStation
      • +Messen - MicroStation
      • +Modelle - MicroStation
      • +OLE - MicroStation
      • Other - MicroStation
      • +Parametrics - MicroStation
      • Printing - MicroStation
      • +Programmierung - MicroStation
      • Programming - MicroStation
      • +Projektnavigation - MicroStation
      • Pseudozellen mit Texten, Font ändern
      • +Punktwolke - MicroStation
      • +Raster - MicroStation
      • +Referenz - MicroStation
      • +Sonstiges - MicroStation
      • +Standards - MicroStation
      • +Stapelverarbeitung - MicroStation
      • +Tabellen - MicroStation
      • +Text - MicroStation
      • +Visualisierung - MicroStation
      • +Volumenelemente
      • +Volumenelemente - MicroStation
      • +Zeichenhilfen - MicroStation
      • +Zellen - MicroStation
      • Zellen mit Sachdaten auflösen und Sachdaten erhalten
      • Zoom gleichzeitig auf 2 Fenster anwenden mit VBA Eventhandler
      • +Änderungsverfolgung - MicroStation
    • +MicroStation PowerDraft

    You are currently reviewing an older revision of this page.

    • History View current version

    MicroStation CONNECT Edition Konfigurations-Variablen (deutsch)

      Produkt(e): MicroStation
      Version(en): 10.00.00.30
      Umgebung: N\A
      Produktbereich: Konfiguration
      Produktunterbereich: Allgemein

    Diese Wiki ist noch in Bearbeitung durch YLohse 10.11.2015


    Dieser Artikel enthält eine Beschreibung der veröffentlichten Konfigurations Variablennamen in MicroStation CONNECT Edition.
    MicroStation enthält verschiedene KonfigurationsVariablennamen, die nicht in diesem Dokument genannt sind. Nicht dokumentierte KonfigurationsVariablennamen sollten nur in ganz bestimmten Situationen verwendet werden (d.h. sie sind nicht für "den allgemeinen Gebrauch" bestimmt).

    Kategorien

    Zellen

    Farben

    Datendateien

    Datenbank

    Zeichnungsapplikationen

    Zeichnungshistorie

    Verteilte DGN

    DWG/DXF (Allgemein)

    DWG/DXF (Öffnen-Spezifisch)  ·

    DWG/DXF (Speichern-Spezifisch)  ·

    Engineering Links

    Erweiterungen

    Erweiterungen (JT-Dateien)  

    Dateispeicherung

    Geografische Koordinaten

    Ebenen

    Makro Rekorder

    Markup

    OLE

    Operation

    Punktwolke

    Hauptsuchpfade  ·

    Drucken

    Schutz

    Raster

    Referenzen

    Rendern / Bilder

    Berichte

    Sicherheit

    Seed Dateien

    Rechtschreibung

    Standards-Prüfung

    Symbolik

    Systemumgebung

    Tabellen

    Sachdaten

    Temp- und Backupdateien

    CGM-Übersetzung

    VBA

    Nicht zugeordnete Variablennamen

    Ungelistete oder Undokumentierte Variablen

    -

    -




    nach unten

    top

    Zellen

    The following table lists the configuration Variablennames that affect cells. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_CELL Cell Library Directories Suchpfad(e) für Zellbibliotheken.
    MS_CELLLIST Cell Library List Liste von Zellbibliotheksdateien, in denen nach Zellen, die in der aktuellen Bibliothek nicht auffindbar sind, gesucht werden soll. Kann Wildcards enthalten.
    MS_CELLSELECTORDIR Cell Selector Directory Verzeichnis für Zell-Selektor-Schaltflächen-Konfigurationsdateien (.csf).
    MS_CELLSELECTOR Cell Selector File Standard-Zell-Selektor-Schaltflächenkonfigurationsdatei.
    MS_CELLOUT Output Cell Libraries Standardverzeichnis zum Erstellen neuer Zellbibliotheken.
    MS_MENU Menu Cells Zellbibliotheksname zum Suchen von Menüzellen.
    MS_RESOLVESCNAMECONFLICTS Shared Cell Name Conflicts Steuert, wie Namenskonflikte von Pseudozellen für Operationen wie das Zusammenführen von Referenzen gehandhabt werden:
    0: keine Auflösung, Pseudozellendefinition aus dem Ziel verwenden
    1: Namenskonflikte für DWG-Pseudozelleninstanzen auflösen (Standardeinstellung)
    2: Namenskonflikte für alle nicht-anonymen Pseudozellen auflösen




    top

    Farben

    The following table lists the configuration Variablennames that affect Color. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_DEFCTBL Default Color Table Standard-Farbtabelle, die verwendet wird, wenn der Zeichnungsdatei keine zugeordnet ist.
    MS_RMENCTBL Right Menu Color Table Voreingestellte Menü-Farben (Dialoge, Rahmen usw.) für den rechten Bildschirm. Dateispezifikation, die auf eine Farbtabellendatei (.tbl) zeigt.
    MS_LMENCTBL Left Menu Color Table Standard-Menü-Farben (Dialoge, Rahmen usw.) für den linken Bildschirm. Dateispezifikation, die auf eine Farbtabellendatei (.tbl) zeigt.
    MS_COLORBOOK_LIBRARIES Colorbook Library List Liste der DGN-Dateien, die als Quelle für Farbbücher dienen
    MS_SYSTEM_COLORBOOKS System Color Books Directory Verzeichnis, das die (mit $[_USTN_PRODUCT_NAME] gelieferten) Systemfarbbücher enthält.




    top

    Datendateien

    The following table lists the configuration Variablennames that affect Data Files. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_CUSTOMSHEETSIZEDEF Sheet Size Definitions

    Definiert den Speicherort der Definitionsdatei für Blattgrößen, die bei der Erstellung von Blattmodellen verwendet werden kann.

    MS_CUSTOMSCALEDEF Scales Definitions Definiert den Speicherort der Maßstabdefinitionsdatei, die bei der Erstellung von Modellen verwendet werden kann.
    MS_CUSTOMUNITDEF Unit Definitions for Upgrading

    Legt die Position der Einheitendefinitionsdatei fest, die zum Aktualisieren von Dateien vor Version V8 auf V8-DGN-Dateien verwendet werden kann.

    MS_HTMLDGNDIR HTML Template Directory

    Verzeichnis, das Zeichnungsdatei-Vorlagen enthält, die vom HTML-Autor zum  Erstellen von Bildzellen für HTML-Dokumente verwendet werden.

    MS_WMS_SERVERS_SEED Seed file for MS_WMS_SERVERS file

    Dient zur Erstellung einer neuen Datei MS_WMS_SERVERS, wenn die Datei MS_WMS_SERVERS noch nicht vorhanden ist.

    MS_WMS_SERVERS Web Map Service Servers Liefert die Liste der Server für die Web Map Service Dialoge.
    MS_DATETIMEFORMATS Standard Date Time formats Enthält eine Liste verfügbarer Formate, die im Feldeditor für Datums-/Uhrzeit-Felder verfügbar sind.
    MS_SETTINGS Settings Resource Verzeichnis, das die Ressourcendateien für Einstellungen enthält.
    MS_SETTINGSOUTDIR Settings Output Directory Verzeichnis für die Erstellung von Ressourcendateien für Einstellungen.
    MS_SETTINGSDIR Settings Directory Directory containing settings files.
    MS_REMAP_CSVFILE Remap CSV File

    Wenn diese Konfigurationsvariable auf eine Neuzuordungsdatei mit durch Komma getrennten Werten (CSV) zeigt, wird diese Datei während der 'Speichern unter'-Operation für die Neuzuordnung standardmäßig als Neuzuordnungsfilter verwendet

    MS_BSILOG_CONFIG_FILE Logging config file

    Speicherort der Datei, die die Diagnoseprotokollierung steuert und konfiguriert. Der Standardwert ist $(MS_DATA)BSILOG.CONFIG.XML.

    MS_BSILOG_ENABLE Enable diagnostic logging Protokollierung von Diagnosemeldungen aktivieren Der Standardwert ist "0".




    top

    Datenbank

    The following table lists the configuration Variablennames that affect database operations. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_UDLDIR Universal Data Link directory Pfad des Verzeichnisses, in dem die UDL-Dateien (Universal Data Link) gespeichert sind.
    MS_ORACLE_HOME Oracle Home

    Pfad für die zur Verbindung mit dem Datenbank-Server erforderlichen Oracle-Client-Dateien. Wenn diese Variable nicht gesetzt ist, sucht $[_USTN_PRODUCT_NAME] in der Systemregistrierung und -pfad, um das Oracle Home-Verzeichnis zu bestimmen.

    MS_DBASE Database Files Suchpfad(e) für Datenbank-Dateien.
    MS_SERVER Server Loader MDL-Applikation, mit der der Datenbank-Server geladen wird.
    MS_DBEXT Database Server Die Datenbank-Server-Applikation.
    MS_LINKTYPE Database Linkages

    WARNUNG: Diese Konfigurationsvariable wird durch die Datenbank-Konfigurationsdateien zurückgesetzt.
    Änderungen sollten in den Dateien BUDBC.cfg, ODBC.cfg, OLEDB.cfg oder Oracle.cfg vorgenommen werden. Diese Variable steht für die Verknüpfungsarten von Benutzerdaten, die der Server erkennt. Die erste in der Liste befindliche Verknüpfungsart wird erstellt. Mögliche Werte sind "BUDBC", "DMRS", "ORACLE", "OLEDB" und "ODBC".




    top

    Zeichnungsapplikationen

    VariablennameBeschreibungDetailierte Beschreibung
    MS_DGNAPPS Design File Applications  Liste aller MDL-Applikationen für Zeichnungsdateien.




    top

    Design History

    MicroStation includes configuration Variablennames to help set up all aspects of the design history.

    The following table lists the configuration Variablennames that affect Design History. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect, unless noted otherwise below.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_DESIGN_HISTORY_COMMIT_ON_SAVE Commit on save Legt fest, ob der Befehl 'Datei > Speichern' (^S) Änderungen in der Zeichnungshistorie eintragen soll. Mögliche Werte:
    2 - Speicherbefehl soll Änderungen ohne Benutzeraufforderung und ohne Beschreibung in die Zeichnungshistorie eintragen.
    1 - Speicherbefehl soll den Benutzer auffordern und ihm die Gelegenheit geben, Änderungen mit einer Beschreibung in die Zeichnungshistorie einzutragen.
    0 - Speicherbefehl soll Änderungen in der Zeichnungsdatei speichern, soll diese jedoch nicht in der Zeichnungshistorie eintragen und den Benutzer nicht dazu auffordern.
    Der Standardwert ist 0 (nicht auffordern oder eintragen).
    MS_DESIGN_HISTORY_COMMIT_ON_CLOSE Commit before close Legt fest, ob Änderungen vor dem Schließen der Datei in die Zeichnungshistorie eingetragen werden sollen. Mögliche Werte:
    2 - Schließbefehl soll Änderungen ohne Benutzeraufforderung und ohne Beschreibung in die Zeichnungshistorie eintragen.
    1 - Schließbefehl soll den Benutzer auffordern und ihm die Gelegenheit geben, Änderungen mit einer Beschreibung in die Zeichnungshistorie einzutragen.
    0 - Schließbefehl kann Änderungen in der Zeichnungsdatei speichern, aber soll weder Änderungen in die Zeichnungshistorie eintragen noch eine Benutzeraufforderung anzeigen.
    Der Standardwert ist 0 (nicht auffordern oder eintragen).
    MS_DESIGN_HISTORY_COMMIT_ON_MODEL_SWITCH Commit on model switch Legt fest, ob der Benutzer zur Bestätigung aufgefordert werden soll, wenn er eine Datei öffnet, die von einem anderen Benutzer vorgenommene Änderungen enthält, die noch nicht eingetragen wurden Mögliche Werte:
    1 - Vor dem Öffnen der Datei Bestätigung anfordern.
    0 - Datei öffnen, ohne Bestätigung anzufordern.
    Standardwert ist 1 (Aufforderung).
    MS_DESIGN_HISTORY_OWNERSHIP_WARNING Confirm when taking ownership Legt fest, ob der Benutzer zur Bestätigung aufgefordert werden soll, wenn er eine Datei öffnet, die von einem anderen Benutzer vorgenommene Änderungen enthält, die noch nicht eingetragen wurden Mögliche Werte:
    1 - Vor dem Öffnen der Datei Bestätigung anfordern.
    0 - Datei öffnen, ohne Bestätigung anzufordern.
    Standardwert ist 1 (Aufforderung).
    MS_DESIGN_HISTORY_COLORS Colors Die Symbolik, die bei der Erkennung geänderter und ungeänderter Elemente verwendet werden soll. Der Wert muss eine Liste von bis zu sechs Symbolikbeschreiber in der folgenden Reihenfolge darstellen: hinzugefügt; gelöscht; geändert; vorgeändert; Konflikte; Hintergrund. Ein Symbolikdeskriptor ist: {Farbe,Strichstärke,Stil,Transparenz}, wobei 'Farbe' einer Menüfarben-ID zwischen 0 und 31, 'Strichstärke' einer Strichstärke zwischen 0 und 31, 'Stil' einem Strichartenindex zwischen 0 und 7 und 'Transparenz' einem Wert zwischen 0 und 255 entspricht. Verwenden Sie -1 für jeden Aspekt der Elementsymbolik, der nicht geändert werden soll. Beispiel: Mit {2,3,1,200}; {4,3,1,200}; {1,3,1,200}; {3,3,1,200}; {6,3,1,200}; {-1,-1,-1,-1} werden betroffene Elemente mit einer punktierten Markierung in Grün, Rot, Blau, Cyan oder Gelb versehen, ohne dass ihre Symbolik geändert wird. Wenn nur eine Farbe angegeben wird, können die geschweiften Klammern weggelassen werden. Die Standardeinstellung lautet: 2; 4; 1; 3; 6; 10, was bedeutet, dass hinzugefügte Elemente in sattem Grün, gelöschte Elemente in Rot, geänderte Elemente in Blau, vorgeänderte Elemente in Cyan, Konflikte in Gelb und ungeänderte Elemente in Mittelgrau gezeichnet werden.
    MS_DESIGN_HISTORY_REVISION_NUMBER_FORMAT Revision number display format Legt fest, wie eine Revisionsnummer angezeigt werden soll. Die Syntax lautet:
    formatClause := { [ ""["" range ""]"" ] msgFormatPattern }+
    range := start [,end]
    msgFormatPattern := string [ ""{"" msgFormatElement ""}"" string ]*
    msgFormatElement := argument [ "","" elementFormat ]
    elementFormat := ""number"" | ""cardinal"" |  ""letter"" [ "","" letterStyle ]
    letterStyle   := { ""uppercase""|""lowercase""|""AA""|""AB""|{""omit"" letter}* }+
    Der Standard ist {0}.{1}
    MS_DESIGN_HISTORY Design History capabilities Gültige Schlüsselwörter: create, delete, commit, browse, tag, changedesc, changeauthor, combine, retire, setrevisionformat, setversion, autoupgrade. Definieren Sie für das Schlüsselwort den Wert 1 zum Aktivieren bzw. 0 zum Deaktivieren. Trennen Sie die verschiedenen Einstellungen durch ';'
    Standardwert: MS_DESIGN_HISTORY=create=1;delete=0;commit=1;browse=1;tag=1;changedesc=0;changeauthor=0;combine=0;retire=0;setrevisionformat=1;setversion=1;autoupgrade=0
    Beispiel: MS_DESIGN_HISTORY=delete=1.
    Dies ermöglicht den Benutzern das Entfernen der Zeichnungshistorie.
    Beispiel: MS_DESIGN_HISTORY=delete=0;combine=1;retire=1.
    Dies verhindert, dass Benutzer die Zeichnungshistorie entfernen, ermöglicht ihnen jedoch, Revisionen zu kombinieren oder zu entfernen.
    Beispiel: MS_DESIGN_HISTORY=changedesc=1.
    Ermöglicht Benutzern, die Beschreibung von Revisionen nach der Aktion zu ändern.
    MS_DESIGN_HISTORY_COMMIT_DOC_PROPERTIES Include document properties in design history? Soll die Zeichnungshistorie Änderungen an Dokumenteigenschaften wie Titel, Autor und Kommentar aufzeichnen?
    Die Standardeinstellung ist '1' (Dokumenteigenschaften in Historie einbeziehen).




    top

    Verteilte DGN

    The following table lists the configuration Variablennames that affect Distributed DGNs. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    Note: These configuration Variablennames take effect only when the product is integrated with ProjectWise with Distributed DGN functionality enabled. Distributed DGN functionality is not available for production workflows.
     
    VariablennameBeschreibungDetailierte Beschreibung
    MS_DISTRIBUTED_DGN_AUTO_FOCUS_ON_NEW_CONFLICTS Should Conflicts dialog pop up? Legt fest, ob der Dialog 'Konflikte' eingeblendet werden soll, wenn der Befehl 'Lokale Kopie aktualisieren' neue Konflikte erkennt. Die Standardeinstellung lautet 'Ein'.
    MS_DISTRIBUTED_DGN_CONFLICT_BY Conflicts scope Legt fest, wie Konflikte erkannt werden sollen. Mögliche Werte:
    MODEL – Änderungen in ein und demselben Modell sind Konflikte,
    GG – Änderungen im Zusammenhang mit ein und derselben Grafikgruppe sind Konflikte.
    ELEMENT - Änderungen an ein und demselben Modell sind Konflikte.
    Die Standardeinstellung lautet MODEL.




    top

    DWG/DXF (Allgemein)

    MicroStation includes configuration Variablennames to help open, edit, and reference AutoCAD DWG data. The following table lists the configuration Variablennames that affect MicroStation's DWG operations.

    Configuration VariablennameDetailierte Beschreibung
    MS_ACADDIR Verzeichnis, in dem sich AutoCAD befindet. In diesem Verzeichis wird nach den DWG-Unterstützungsdateien wie etwa Schriftarten gesucht (Siehe MS_DWGFONTPATH).
    When you first load the product, it reads the registry, determines whether AutoCAD or AutoCAD LT is installed on your computer, and if present, sets this configuration variable.
    MS_BLOCKLIST Liste der DWG/DXF-Dateien, die in den AutoCAD-Blöcken gesucht werden sollen.
    You can use this configuration variable when you click on Display All Cells in MS_CELLLIST icon in the Cell Library dialog..
    MS_DWG_BACKUP Defines the directory for the DWG backup (.bak) files. If not set, the backup files are placed in the same directory as the DWG file.
    MS_DWG_COMMANDPREFIX Definiert das Präfix für Eingaben, die auf DWG-Befehle verweisen.
    MS_DWG_CREATE_SPACE_FROM_EDF If set to 1, any empty data field remains as a space.
    MS_DWG_FEETUNIT_AS_ARCHENG If set, when a DGN file with Working Units set to Feet-Inches, Format set to Master Units, and Units on the Save As DWG/DXF Options dialog set to Master Units, the resulting DWG file has Engineering or Architectural units in AutoCAD. (If not set, the units are Decimal or Fractional.)
    For details, see Setting units in files that will be saved to DWG files..
    MS_DWG_FIELD_2005FORMATTING If defined and set to 1, the product only generates field information that AutoCAD 2005 supports.
    MS_DWG_LSTYLE_FONTPATH Determines the location of the font file.
    MS_DWG_LSTYLE_FONTNAME Determines the name of the font file, and therefore, the name of the font.
    MS_DWG_MAX_ORPHANTAGS_PERSET Set the maximum number of tags per tagset for "orphan tags." An orphan tag is an attribute definition that is never instantiated in a block as it should in a DWG file. When opening a DWG file, all such “dangling” attribute definitions are collected into a tagset. For better performance, a tagset should be limited to a manageable size. Therefore, in the case of a large number of dangling attribute definitions, multiple tagsets are preferred rather than one large tagset. The default size is 100 per tagset.
    MS_DWG_PGPFILE PGP-Dateien enthalten Aliasnamen für DWG-Befehle. Wenn kein Verzeichnis angegeben ist, wird das Verzeichnis für AutoCAD-Unterstützung verwendet.
    MS_DWG_PRE2004_COLOR_TABLE Sets the color table for DWG files in the product. In version 2004, AutoCAD began displaying indexed colors with a slightly different (generally lighter) colors. The product also uses these new colors unless this Variablenname is set.
    MS_DWGAUTOSAVE If set to a positive number, specifies the number of seconds after the first change to the DWG or DXF file that auto-save occurs. When this time elapses, an Alert window appears that asks whether the changes should be saved. The saving time can be significant, so you can defer the saving by clicking Cancel. If set to zero, no auto-save is done while the file is open. The file is automatically saved on exit or when switching to a different file.
    MS_DWGAUTOSAVE_NODIALOG If set to a positive number, specifies the number of seconds after the first change to the DWG or DXF file that auto-save occurs. When this time elapses the Alert window is skipped and the file change is automatically saved.
    MS_DWGDATA Lokales Verzeichnis zum Speichern von DWG-Einstellungsdateien.
    • DwgSettings.rsc — resource file containing all of the DWG settings
    • Files (*.dws) containing saved settings for opening and saving DWG/DXF files.
    • DwgDisplayColors.tbl (Optional) — A color table that contains the fixed AutoCAD colors used for display to the screen.
    • DwgPlotColors.tbl (Optional) — A color table that contains the fixed AutoCAD colors used for plotting.
    MS_DWGFONTPATH Pfad oder Pfadliste der AutoCAD SHX-Schriften. if AutoCAD is not installed on the system.
    By default, the product first uses the value of the MS_ACADDIR configuration Variablenname to find AutoCAD support files. If this is unavailable, the product uses individual Variablennames, such as MS_DWGFONTPATH.
    MS_DWGOMITUNIQUEEXTENSION If more than one file with the same name is present in the same directory, appends the extension to the output filename when saving the file.
    For example, if the directory contains both sample.s01 and sample.s02, then the extension is included in the output filenames (sample_s01.dgn and sample_s02.dgn). If the directory does not include any files with duplicate names, then the extensions are be included in the output names. For example, if the directory contains only file sample.s02, this file is saved to sample.dwg.
    MS_DWGPATFILE Defines the full path file name that contains AutoCAD pattern definitions.
    MS_DWGREF_ALLOWMASTERCOLORS Defines how the product uses color tables for DWG or DXF files attached as references.
    • If MS_DWGREF_ALLOWMASTERCOLORS is set to 1, the color tables for DWG or DXF references are handled as they are for DGN references: they are controlled by the Use Color Table setting in the Preferences dialog Reference Category ( File > Settings > User > Preferences ). When Use Color Table is on, the elements in each reference are displayed using the reference's color table. When Use Color Table is off, the elements in each reference are displayed using the active design file's color table.
    • If MS_DWGREF_ALLOWMASTERCOLORS is not set to any value, DWG or DXF references are always displayed using the reference file's color table. In this case, the Use Color Table setting has no effect.
    MS_DWGSEED Defines the DWG seed file used when opening DWG files.
    MS_DWGSEED_OVERRIDE Determines whether a user can modify the DWG Seed File setting on the Save As DWG/DXF Options dialog.
    When the Variablenname is not set or set to 0, the first time that the dialog opens, the default DWG seed file is set by the MS_DWGSEED configuration Variablenname. You can choose a different seed file
    When the Variablenname is set to 1, You can only use the DWG seed file identified by MS_DWGSEED. You cannot choose a different seed file.
    When the Variablenname is set to 2, the default DWG seed file is set by MS_DWGSEED at the beginning of each session. You can choose a different seed file during the session.
    MS_DWGSETTINGSFILE

    Datei mit Einstellungen zum Öffnen und Speichern von DWG-Dateien.

    MS_DWGSHEETMODELSEED Identifies the file containing the seed model for new sheet models in DWG files.
    MS_DWGSHEETMODELSEEDNAME Identifies the seed model for new sheet models in DWG files.
    MS_DWGSYSTEMDATA

    Verzeichnis, mit dem das lokale Verzeichnis als Quelle für DWG-Einstellungsdateien außer Kraft gesetzt werden kann.
    Identifies the directory containing the DWG settings file Dwgsettings.rsc. Overrides the directory specified by MS_DWGDATA.
    The display and plotting color tables (DwgDisplayColor.tbl and DwgPlotColors.tbl) can also be controlled by placing them in this directory.

    MS_MERGE_DISPLAYEDLEVELSONLY Modifies Copy Levels During Merge setting on the References tab of the Save As DWG/DXF Options dialog, Save As V8 Options dialog or Saved as V7 Options dialog.
    When set (to 1), only those reference levels that are displayed in the selected view are merged into the output file.
    If not set, and the Merge Displayed Levels Only setting is off (in the References tab), then all reference levels are merged into the output file.
    MS_NO_DWG_BACKUP If set, backup files (.bak) are not created when you edit a DWG or DXF file.
    MS_TRANSEED_OVERRIDE Determines whether a user can modify the DGN Seed File setting on the DWG Open Options dialog.
    When the Variablenname is not set or set to 0, the first time that the dialog opens, the default DGN Seed File is set by the MS_TRANSEED configuration Variablenname. You can choose a different seed file.
    When the Variablenname is set to 1, You can only use the DGN seed file identified by MS_TRANSEED. You cannot choose a different seed file.
    When the Variablenname is set to 2, the default DGN seed fie is set by MS_TRANSEED at the beginning of each session. You can choose a different seed file during the session.
    MS_WORKMODE Defines the workmode as either DGN or DWG.




    top

    DWG/DXF (Open-Specific)

    MicroStation includes configuration Variablennames to open AutoCAD DWG data. Valid values must be entered exactly as shown in the table. For example, “Region” Entity must be entered as a whole string.

    Note: Many DWG/DXF open-specific configuration Variablennames have an equivalent setting in the GUI. When set correctly they will override the values in the DWG settings GUI.

    Configuration VariablennameDetailierte Beschreibung
    MS_DWG_ALERT_DEC_FRC_SCI_UNITS When a DWG file is opened, an alert dialog opens to warn that Decimal/Fractional/Scientific units are not set to Design Center units. Valid values are ON (or no value) or OFF.
    MS_DWG_ALERT_DESIGNCENTER_UNITS When a DWG file is opened, an alert dialog opens to warn that Design Center units are not set to a specific unit. Valid values are ON (or no value) or OFF.
    MS_DWG_ALERT_ENG_ARCH_UNITS When a DWG file is opened, an alert dialog opens to warn that Architectural/Engineering units are not set to Inches. Valid values are ON (or no value) or OFF.
    MS_DWG_ARCH_ENG_UNITS Sets units to open DWG files that use Architectural or Engineering units. Valid values are:
    Master Units
    Sub Units
    Design Center Units
    a unit defined in file units.def
    MS_DWG_AXISLOCK_FROM_ORTHOMODE If DWG ORTHOMODE=1, sets the Axis Lock. Valid values are ON (or no value) or OFF.
    MS_DWG_DEC_FRC_SCI_UNITS Sets units to open DWG files that use Decimal, Fraction or Scientific units. Valid values are:
    Master Units
    Sub Units
    Design Center Units
    a unit defined in file units.def
    MS_DWG_DESIGNBACKGROUND_COLOR Sets the background color for the default design model. Valid values are Red, Green, or Blue, where each of the three color indices is an integer between 0 and 255.
    MS_DWG_DESIGNCENTER_UNITS Sets units to open DWG files that use Design Center Units. Valid values are:
    Master Units
    Sub Units
    a unit defined in file units.def
    MS_DWG_DISCARD_INVALID If set, entities that are outside the DGN design plane are discarded and will not be written back to the DWG file on the next file save. If the Variablenname is not set, the product ignores these entities. Typically these entities are not valid and will cause the AutoCAD Zoom Extents tool to perform poorly.
    MS_DWG_FOREGROUNDCOLOR255RGB Sets the RGB value to display DWG color index 255 as the foreground color, with red, green, and blue values separated by commas. For example, setting MS_DWG_FOREGROUNDCOLOR255RGB=255,255,255 will display DWG index color 255 as white. If this configuration Variablenname is not set, a grayish color is displayed. This is a workaround for DWG's ambiguous index color 255, which serves both as a background color for wipeout fill and as a foreground color for other entities. The foreground definition is remapped by this configuration Variablenname and the RGB value is saved as a named color "DWG Color 255" in a color book called "DWG Special Colors."
    MS_DWG_GRAPHIC_GROUP_ATTRIBUTES Sets blocks to Graphic Groups, that is, puts shared cell and attached tags into a graphic group. Valid values are ON (or no value) or OFF.
    MS_DWG_LINEWEIGHT_MAPPING Maps DWG line weights to DGN line weights. Valid values are 0=DWG weight1; 1=DWG weight2; 2=DWG weight3; and so forth to 31=DWG weight31, where DWG weights are the DWG line weight values in millimeters, for examples, 0.0, 0.13, 2.11.
    MS_DWG_LWDEFAULT Controls the width of the default line weight and is analogous to the AutoCAD registry Variablenname LWDEFAULT. The default value is 0 for unweighted default lines. Valid LWDEFAULT values are From AutoCAD Registry, 0.00 mm, 0.05 mm, 0.09 mm, 0.13 mm, 0.15 mm, 0.18 mm, 0.20 mm, 0.25 mm, 0.30 mm, 0.35 mm, 0.40 mm, 0.50 mm, 0.53 mm, 0.60 mm, 0.70 mm, 0.80 mm, 0.90 mm, 1.00 mm, 1.06 mm, 1.20 mm, 1.40 mm, 1.58 mm, 2.00 mm, 2.11 mm. The Line weight index is also a valid alternative, that is, any integer from 0 through 211. A line weight index is an enumeration of line weight defined by DXF Group Code 370.
    MS_DWG_MAX_DICTIONARYITEMS (Affects DWG files with many dictionary items.) A dictionary item is non-graphical data stored in the DWG file that often does not impact the visible elements. When opening a file, if the DWG file has a large number of these items, performance can be slow. To speed up the file opening process, you can ignore this items. If you need these dictionary items, you can opt to keep them in spite of poor performance. This Variablenname sets the number of dictionary items you want to keep.
    MS_DWG_MODELSPACE Sets the model space to 2D or 3D. Valid values are 2D or 3D.
    MS_DWG_PAPERSPACE Sets the paper space to 2D or 3D. Valid values are 2D or 3D.
    MS_DWG_PROXYSHOW Controls the display of proxy objects within a DWG drawing. It is analogous to the AutoCAD registry setting PROXYSHOW. Valid values are:
    From AutoCAD Registry
    Do Not Show Proxy
    Show Proxy Image
    Show Proxy Box
    An alternative is an integer value such as 0 – do not show graphics, 1 – show graphics, or 2 – show boundary box only. The default setting is 1.
    MS_DWG_PROXY_VIEW Sets a view to be displayed for a multi-view proxy. Valid values are:
    Top
    Front
    Left
    Isometric
    MS_DWG_REFERENCE_CONVERT Converts reference files to DWG files. Valid values are ON (or no value) or OFF.
    MS_DWG_REFERENCE_COPYLEVEL Sets the conditions to copy reference levels during merge: only if they are not in the target file, if they are overridden, or always copy. Valid values are If Not Found, If Overrides Exist, or Always.
    MS_DWG_REFERENCE_COPYNESTED Copies live nested reference attachments to the target file when merging. Valid values are ON (or no value) or OFF.
    MS_DWG_REFERENCE_EXTERNAL Saves external reference file attachments to be an Xref attachment (retained), merged, merged as a block, or omitted. Valid values are:
    Retain
    Merge
    Merge To Cell
    Omit
    MS_DWG_REFERENCE_MASKED Saves masked reference file attachments to be an Xref attachment (retained), merged, merged as a block, or omitted. Valid values are:
    Retain
    Merge
    Merge To Cell
    Omit
    MS_DWG_REFERENCE_MERGE_DISPLAYEDLEVELSONLY Merges reference levels only if they are displayed. Valid values are ON (or no value) or OFF.
    MS_DWG_REFERENCE_OPTIMIZEDCLIP Optimizes reference clipping when merged. Valid values are ON (or no value) or OFF.
    MS_DWG_REFERENCE_SELF Saves self-referenced file attachments to be an Xref attachment (retained), merged, merged as a block, or omitted. Valid values are:
    Retain
    Merge
    Merge To Cell
    Omit
    MS_DWG_RENDER_LIGHTSOURCE_OPEN Sets to use light source for rendering. Valid values are ON (or no value) or OFF.
    MS_DWG_RENDER_MATERIAL_OPEN Sets to use materials for rendering. Valid values are ON (or no value) or OFF.




    top

    DWG/DXF (Close-Specific)

    MicroStation includes configuration Variablennames to save AutoCAD DWG data. Valid values must be entered exactly as shown in the table. For example, “Region” Entity must be entered as a whole string.

    Note: Many DWG/DXF save-specific configuration Variablennames have an equivalent setting in the GUI. When set correctly they will override the values in the DWG settings GUI.
     

    Configuration VariablennameDetailierte Beschreibung
    MS_DWG_2D_UNFILLED_3OR4SIDED_SHAPE Converts 2D unfilled triangles and quadrangles to polyline, face, polyface mesh, or region entities. Valid values are:
    Face” Entity
    Region” Entity
    Polyface Mesh
    Polyline
    MS_DWG_2D_UNFILLED_5ORMORESIDED_SHAPE Converts 2D unfilled polygons to polyline, polyface mesh, or region entities. Valid values are:
    Region” Entity
    Polyface Mesh
    Polyline
    MS_DWG_2D_UNFILLED_COMPLEX_SHAPE Converts 2D unfilled complex shapes to polyline, polyface mesh, or region entities. Valid values are:
    Region” Entity
    Polyface Mesh
    Polyline
    MS_DWG_2D_UNFILLED_GROUPHOLE Converts 2D unfilled group hole elements to polyface mesh or region entities. Valid values are:
    “Region” Entity
    Polyface Mesh
    MS_DWG_3D_UNFILLED_3OR4SIDED_SHAPE Converts 3D unfilled triangles and quadrangles to polyline, face, polyface mesh, or region entities. Valid values are:
    “Face” Entity
    “Region” Entity
    Polyface Mesh
    Polyline
    MS_DWG_3D_UNFILLED_5ORMORESIDED_SHAPE Converts 3D unfilled polygons to polyline, polyface mesh, or region entities. Valid values are:
    Region” Entity
    Polyface Mesh
    Polyline
    MS_DWG_3D_UNFILLED_COMPLEX_SHAPE Converts 3D unfilled complex shapes to polyline, polyface mesh, or region entities. Valid values are:
    Region” Entity
    Polyface Mesh
    Polyline
    MS_DWG_3D_UNFILLED_GROUPHOLE Converts 3D unfilled group hole elements to polyface mesh or region entities. Valid values are:
    Region” Entity
    Polyface Mesh
    MS_DWG_ACS_TO_UCS Converts ACS to UCS. Valid values are ON (or no value) or OFF.
    MS_DWG_BLOCKDEF_ON_LAYER0 Saves the block definitions on layer “0.” Valid values are ON (or no value) or OFF.
    MS_DWG_BLOCKNAMES_FROM_TRIFORMA_PARTS Sets the block names from Building parts. Valid values are ON (or no value) or OFF.
    MS_DWG_BYBLOCK_COLOR Sets the block definitions to use the color BYBLOCK. Valid values are ON (or no value) or OFF.
    MS_DWG_BYBLOCK_LINETYPE Sets the block definitions to use line type BYBLOCK. Valid values are ON (or no value) or OFF.
    MS_DWG_BYBLOCK_WEIGHT Sets the block definitions to use line weight BYBLOCK. Valid values are ON (or no value) or OFF.
    MS_DWG_CONSTRUCTION_CLASS Sets the elements of the construction class to “Construction” layer, “Defpoints” layer, element’s own layer, invisible, or omits them. Valid values are:
    Save To “Construction” Layer
    Save To “Defpoints” Layer
    Save
    Save As Invisible
    Omit
    MS_DWG_CONVERT_RSC_FONTS Converts and creates SHX files from RSC fonts. Valid values are ON (or no value) or OFF.
    MS_DWG_CREATE_SEPARATE_SHEETS When a DGN file containing sheet models is saved to DWG, the sheets are usually saved to separate layouts within the DWG file. If this Variablenname is set, the sheets are saved to separate DWG files with the file name created by appending the model name to the original file name. Valid values are ON (or no value) or OFF.
    MS_DWG_CURVED_SOLIDSURFACE Converts curved solids and surfaces to wireframe, polyface mesh or ACIS entities. Valid values are:
    Wireframe
    Polyface Mesh
    ACIS Entity
    MS_DWG_CURVES Converts curves to spline curves or polyline curves. Valid values are:
    Spline Entity
    Polyline
    MS_DWG_DROP_LABELLINES When present, a label line dimension will be dropped to single line text when saved to DWG. By default, a label line will become an mtext. If a label line's text positions are important, dropping them to a single line may be desired. Set this Variablenname to any value to turn it on. It is off by default.
    MS_DWG_DROP_UNSUPPORTED_DIMENSIONS Drops dimensions that are not supported by DWG file format. Valid values are ON (or no value) or OFF.
    MS_DWG_DROP_UNSUPPORTED_LS Drops line styles that are not supported by DWG file format. The most possible custom line styles DWG format allows are those with characters in them. Any other types are incompatible. Valid values are ON (or no value) or OFF.
    MS_DWG_EMPTY_EDF_TO_SPACE Converts blank enter data fields to spaces. Valid values are ON (or no value) or OFF.
    MS_DWG_FARREFDEPENDENCY If set to 0 (the default), DWG named groups work as they do in DWG, that is, elements from a reference file are not supported by group. This is a DWG limitation. If set to 1, you can work around that limitation, that is, elements in reference files can be selected and saved in named groups. However, these groups still will not work in AutoCAD. If these groups and elements are edited in AutoCAD, they may not function anymore when the DWG file is reopened in the product.
    MS_DWG_FILE_CODEPAGE Sets the DWG file codepage. Valid values are 1252 (English) , 1251 (Cyrillic), 1253 (Greek), 1254 (Turkish), 1255 (Hebrew), 1256 (Arabic), 1257 (Baltic), 1258 (Vietnam), 874 (Thai), 932 (Japanese), 936 (Simplified Chinese), 949 (Korean), or 950 (Traditional Chinese).
    MS_DWG_FILLED_3OR4SIDED_SHAPE Converts filled triangles and quadrangles to solid, polyface mesh, region or hatch entities. Valid values are:
    “Solid” Entity
    “Region” Entity
    Hatch” Entity
    Polyface Mesh
    MS_DWG_FILLED_5ORMORESIDED_SHAPE Converts filled polygons to polyface mesh, region or hatch entities. Valid values are:
    Region” Entity
    “Hatch” Entity
    Polyface Mesh
    MS_DWG_FILLED_COMPLEX_SHAPE Converts filled complex shapes to polyline, region or hatch entities. Valid values are:
    “Region” Entity
    Hatch” Entity
    Polyline
    MS_DWG_FLAT_SOLIDSURFACE Converts flat solids and surfaces to wireframe, polyface mesh or ACIS entities. Valid values are:
    Wireframe
    Polyface Mesh
    ACIS Entity
    MS_DWG_FORCE_POSITIVE_ARCS For arcs, changes clockwise orientation to counter clockwise. Valid values are ON (or no value) or OFF.
    MS_DWG_FORCE_ZERO_ZCOORDINATE Sets the z-coordinate of an element to have a zero value. Valid values are ON (or no value) or OFF.
    MS_DWG_INDEXCOLOR_TO_TRUECOLOR Converts index color to true color. Valid values are ON (or no value) or OFF.
    MS_DWG_LEADER_HOOKLINE If set, an inline elbow displays on notes that did not have an elbow when first created.
    The product allows a note to be placed without an inline elbow (a hook line in AutoCAD) when the inline toggle is unchecked, but AutoCAD does not. This type of note (for instance, a leader without a hook line) saved to DWG will retain correct graphical presentation, and will operate properly in AutoCAD. However, the audit tool will generate an error (annotation ID not null). The audit error can be resolved by setting this configuration Variablenname to 1. However, the original graphical presentation will be lost (the hook line will appear).
    MS_DWG_LEVEL_DISPLAY Sets the view number from which the level display will be used for the layer’s on/off status. Valid values is a number from 0 through 8.
    MS_DWG_LEVELSYMBOLOGY_OVERRIDE Overrides the element symbology from the level symbology. Valid values are ON (or no value) or OFF.
    MS_DWG_LINEARPATTERN_CLASS Sets the elements of the linear pattern class to “Linear Patterned” layer, “Defpoints” layer, element's own layer, invisible, or omits them. Valid values are:
    Save To “Linear Patterned” Layer
    Save To “Defpoints” Layer
    Save
    Save As Invisible
    Omit
    MS_DWG_LINECODE_SCALE Scales the line code. Valid value is a positive real number.
    MS_DWG_LOGICALNAME_TO_XREFNAME Saves the reference attachment logical name as the block name of an Xref file. Valid values are ON (or no value) or OFF.
    MS_DWG_NONDEF_DESIGNMODEL_ATTACHMENTS Merges the attachments of a non-default design model or merges them as block references. Valid values are:
    Merge
    Merge To Cell
    Omit
    MS_DWG_NONDEFAULT_DESIGNMODEL Saves non-default design models to separate files, layout models (paper space), or ignore them if their attachments are not merged. Valid values are:
    Create Separate Files
    Create Paper Space
    Ignore If Not Merged
    MS_DWG_NONPLANAR_POLYLINES Converts a nearly planar line string to a 2D or 3D polyline. A nearly planar line string is strictly non-planar, but its vertex deviation is small enough to be treated as planar such that it is allowed to become a 2D polyline. Valid values are ON (or no value) or OFF.
    MS_DWG_ONE_BLOCK_FOR_DUP_CELLS Creates one block definition for all type-2 cells that are found to be the same. Valid values are ON (or no value) or OFF.
    MS_DWG_OVERLAY_FOR_REFERENCES Creates overlays for reference attachments (no live esting). Valid values are ON (or no value) or OFF.
    MS_DWG_PATTERN_CLASS Sets elements of pattern class to “Pattern” layer, “Defpoints” layer, element's own layer, invisible, or omits them. Valid values are:
    Save To “Pattern” Layer
    Save To “Defpoints” Layer
    Save
    Save As Invisible
    Omit
    MS_DWG_PFACE_MESH_ANGLE Sets an angular tolerance for polyface mesh conversion. Valid value is a real value in degrees between 0 and 90.
    MS_DWG_PLANARPOLYLINES Converts a planar line string to a 2D or 3D polyline. A planar line string has all its vertices lined up to form a unique plane. They do not have to be on an orthogonal plane; they can be on any plane in space. Valid values are:
    3D Polyline
    Polyline
    MS_DWG_REFERENCE_CONVERT Converts reference files to DWG files. Valid values are ON (or no value) or OFF.
    MS_DWG_REFERENCE_COPYLEVEL Sets the conditions to copy reference levels during merge: only if they are not in the target file, if they are overridden, or always copy. Valid values are:
    If Not Found
    If Overrides Exist
    Always
    MS_DWG_REFERENCE_COPYNESTED Copies live nested reference attachments to the target file when merging. Valid values are ON (or no value) or OFF.
    MS_DWG_REFERENCE_EXTERNAL Saves external reference file attachments to be an Xref attachment (retained), merged, merged as a block, or omitted. Valid values are:
    Retain
    Merge
    Merge To Cell
    Omit
    MS_DWG_REFERENCE_MASKED Saves masked reference file attachments to be an Xref attachment (retained), merged, merged as a block, or omitted. Valid values are:
    Retain
    Merge
    Merge To Cell
    Omit
    MS_DWG_REFERENCE_MERGE_DISPLAYEDLEVELSONLY Merges reference levels only if they are displayed. Valid values are ON (or no value) or OFF.
    MS_DWG_REFERENCE_OPTIMIZEDCLIP Optimizes reference clipping when merged. Valid values are ON (or no value) or OFF.
    MS_DWG_REFERENCE_SELF Saves self-referenced file attachments to be an Xref attachment (retained), merged, merged as a block, or omitted. Valid values are:
    Retain
    Merge
    Merge To Cell
    Omit
    MS_DWG_RENDER_LIGHTSOURCE_SAVE Saves rendering light sources. Valid values are ON (or no value) or OFF.
    MS_DWG_RENDER_MATERIAL_SAVE Saves rendering materials. Valid values are ON (or no value) or OFF.
    MS_DWG_SAVE_DIMENSION_SETTINGS Saves active dimension settings, such as the one listed as Style-none in dimension style dialog. Valid values are ON (or no value) or OFF.
    MS_DWG_SAVE_FILE_SETTINGS Saves file settings such that non-DWG settings can round-trip back. Valid values are ON (or no value) or OFF.
    MS_DWG_SAVE_FRONTBACK_CLIPS Saves front-back clippings. Valid values are ON (or no value) or OFF.
    MS_DWG_SAVE_REFERENCE_PATH Indicates whether/how to save paths for reference attachments. Valid values are:
    When saving to same directory
    Relative to Master File
    Never
    MS_DWG_SAVE_UNITS Sets the file units to be saved. Valid values are:
    Master Units
    Sub Units
    Arch./Engineering
    a unit defined in file units.def
    MS_DWG_SCALE_BLOCKS Scales the block definitions. Valid values are ON (or no value) or OFF.
    MS_DWG_SHEETBACKGROUND_COLOR Sets the background color for sheet models. Valid values are Red, Green, Blue, where each of these color values is an integer between 0 and 255.
    MS_DWG_SHX_OUTPUT_PATH Sets the path to place converted SHX files. Valid value is a path or folder name.
    MS_DWG_SOURCEVIEWGROUP Used to specify a view group name, rather than using the active view group, to save the level display on/off status per view to DWG's global layer display. Because DWG does not support per-view level display, if multiple view groups (for example, the default design model and sheet models) use different per-view level display, only one can be saved as the global layer display for all models.
    When this configuration Variablenname is not set, the active view group determines the global layer display status. When it is set with a valid view group name, that view group determines the global layer display status. When it is set with an invalid view group name, the first view group that points to a sheet model in the file determines the global layer display status. This can be useful if you are saving files in a batch, and each file has only one sheet model which is not always the active model.
    This configuration Variablenname takes effect only if MS_DWG_LEVEL_DISPLAY is set.
    MS_DWG_TEXTSTYLE_NAME_TEMPLATE Sets a text string template to convert text style name. Valid value is a text string that may contain a place holder %s for the font name.
    MS_DWG_VERSION Sets DWG version to be saved. Valid values are 11, 12,13, 14, 2000, 2000i, 2002, 2004, 2005, 2006, 2007, 2008, 2009.
    MS_DWG_VPORT_LAYER_FROM_CLIP Sets the layer of viewport entity from the clipping element.
    Viewport entities are represented as reference attachments in the product – the viewport level is extracted from the reference attachment. If no level is set for the reference attachment then by default the viewport is assigned to layer 0 . However, if this Variablenname is set and a clip element is present, then the viewport layer is extracted from the clip element.
    MS_DWG_VPORT_MAP_LOCATE_OFF_TO_LOCKED If set, the Display locked status of a viewport entity is mapped to the Locate setting of the reference attachments that represent this viewport. In this case, a viewport with Display locked off will have Locate turned off – and changing the Locate status of the reference attachment will change the Display Locked status of the viewport.
    MS_DWG_VPFREEZE Sets the Viewport Freeze per View Level Display option.
    • 0 - Viewports & Global layers
    • 1 - Viewports Only
    • 2 - Force Global Layer display
    MS_DWGINSERTLAYER Specifies the layer to which normal (unshared) cells and reference attachments are assigned when saving the open DGN file in DWG format. If this configuration Variablenname is not defined, layer 0 is used. Valid values are ON (or no value) and OFF.
    MS_DWGSAVEAPPLICATIONDATA Linkage data and type 66 application elements can be saved from DGN to DWG. If set, the applications are stored as XRECORDS and the linkages as XDATA. Valid values are ON (or no value) and OFF. The default is off.
    MS_DXF_PRECISION Sets the number of decimal places for real numbers when saving file to DXF. Valid value is an integer number between 1 and 16.




    top

    Engineering Links

    MicroStation includes configuration Variablennames to help set up all aspects of the design history.

    The following table lists the configuration Variablennames that affect Design History. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_WEBLIB_HISTORY Weblib history Gibt die Historiendatei für die gemeinsam genutzte Bibliothek von Weblib an.
    MS_BOOKMARKS_IMAGE Image bookmarks Gibt die Lesezeichendatei für entfernte Bilder an.
    MS_BOOKMARKS_RSC Resource bookmarks Gibt die Lesezeichendatei für entfernte Ressourcendateien an.
    MS_BOOKMARKS_ARCHIVE Archive bookmarks Gibt die Lesezeichendatei für entfernte Archive an.
    MS_BOOKMARKS_CELL Cell library bookmarks Gibt die Lesezeichendatei für entfernte Zellbibliotheken an.
    MS_BOOKMARKS_DGN DGN bookmarks Gibt die Lesezeichendatei für entfernte Zeichnungsdateien an.
    MS_WEBKIOSKMODE Kiosk mode Für den Kiosk-Modus auf 1 gesetzt.
    MS_WEBTYPESFILE Special filetype handling Gibt eine Datei an, in der sich besondere Anweisungen zum Behandeln von verschiedenen Dateitypen befinden
    MS_WEBFILES_DIR Weblib local storage Gibt das Verzeichnis an, in dem Kopien von entfernten Dateien gespeichert werden.
    MS_WEBDOWNLOADDIR Download directory Hiermit wird das Verzeichnis eingestellt, in dem aus dem WWW heruntergeladene Dateien gespeichert werden.
    MS_BROWSERMAKECHILDWINDOW Reparent browser Wenn die Variable auf 1 gesetzt ist, wird der aktuelle Browser im $[_USTN_PRODUCT_NAME]-Hauptfenster zum übergeordneten Element Dadurch kann
    MS_USEEXTERNALBROWSER External browser name Wird zum Verwenden eines externen Browsers auf Netscape oder Iexplore gesetzt




    top

    Erweiterungen

    The following table lists the configuration Variablennames that affect extensions. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameDetailierte Beschreibung
    EC_EXTENSION_ASSEMBLIES Used for internal implementation. Do not modify.
    MS_ACIS Directory containing the ACIS subsystem.
    MS_APP Search path(s) of applications started from “TSK” statements.
    MS_BATCHPLT_SPECS Sets the location of the batchplt.spc file, which contains the print specifications used by Print Organizer.
    MS_BUTTONMENU Defines the file name for the default mouse button menu. The default name is "default.btnmenu" located in the MS_DATA directory. When you create or modify a button menu, the default button menu acts as a seed for modification.
    MS_CLRUICULTURE Used for internal implementation. Do not modify.
    MS_CUSTOMIZE_REPORT_STYLESHEET Defines the file name and location for HTML reports on templates and customizations. The default style sheet is named “customizereport.xsl” and is stored in ..\Default\Data\ folder of MicroStation's program directory.
    MS_DATA_PDFL Used for internal implementation only. Do not modify.
    MS_DGNTEXTEDITORFAVORITESYMBOLS Defines the file path where the favorite symbol preferences are stored.
    MS_DGNTEXTEDITORFAVORITESYMBOLSSEED Defines the file path that, if exists, and if MS_DGNTEXTEDITORFAVORITESYMBOLS does not, it will be copied once to seed the favorite symbol preferences.
    MS_DGNTEXTEDITORPREF Defines the file path where the text editor preferences are stored.
    MS_DGNTEXTEDITORPREFSEED Defines the file path that, if exists, and if MS_DGNTEXTEDITORPREF does not, it will be copied once to seed the text editor preferences.
    MS_DOCKINGPREF Defines the location of the file that stores docking preferences such as which dialogs are docked, where they are docked, and the size of the docking areas.
    MS_DRAGDROPTYPES Defines location and file name for the file extensions associations. This is accessed through File > Tools > File Associate. The default file name is dragdrop.txt, which will be created in the %LOCALAPPDATA%\Bentley\<product_name>\<product_version>\ folder.
    MS_ECREPOSITORY_PROPERTYENABLER_SKIPPED_ECSCHEMAS Used to remove certain item types from appearing in the Explorer dialog Items tab and Advanced Search dialog. The list is delimited by semicolons and the ECSchema names must be fully qualified with their version number, for example, “MySchema.01.00;BentleyPlant.05.00”. There is rarely a need for users to change it.
    MS_EXPLORERSETTINGSSEED XML file containing default user Explorer settings. This file is used to define Explorer settings if the file defined by MS_EXPLORER_SETTINGS is not found.
    MS_EXPLORER_SETTINGS XML file containing user Explorer settings.
    MS_GPSDEVICES Specifies the GPS devices supported by MicroStation. It should not be changed by users.
    MS_GROUPPANELPREF Defines the location of the file that stores the saved state of group panels in various dialogs. These include dialogs such as View Attributes, and stores the open state of the groups, as well as any custom settings that the dialog can associate with the groups.
    MS_HANDLER_LOAD Used to control element handlers. This Variablenname should not be changed by users.
    MS_KEYPAIRLIST Digital signature KeyPair file list.
    MS_LUXOLOGY Points to the directory where the DLLs related to Luxology are stored.
    MS_MDLSTUB_LOAD List of MDL Applications that will be stub-loaded, which means their resources are loaded but the code portion of the application is not yet loaded.
    MS_POINTCLOUD_APPS Loads any specified MDL applications along with the PointCloud Handler whenever a point cloud is attached in a model. To load the MDL application every time you attach a point cloud, add the name of the MDL application to this Variablenname.
    MS_POINTOOLS Points to the directory where the DLLs related to Pointools are stored.
    MS_POSITIONMAPPING_CONFIGURATION If set to 1, displays the Position Mapping category in the Preferences dialog.
    MS_PROCESSEXCEPTIONLOG MicroStation exception.log and minidump.dmp management.
    MS_PRODUCTCODEGUID Used for internal implementation. Do not modify.
    MS_PROPERTYENABLER_APPS Lists the applications to be loaded that are required for displaying properties in the Properties dialog.
    MS_PUBLISH_EXTENSIONSASSEMBLIES Used for internal implementation. Do not modify.
    MS_RASTER_DEF_DIR If absent, there is no Effect.
    If present, defines the default directory to which the Attach Raster Reference menu will point to (Default raster file open directory).
    MS_REALDWG_APPS Lists the adapters for cooperative object enablers that will be loaded into the product when it starts.
    MS_SELECTBY Defines the directory for the selectby.rsc file to be written to and read from. The selectby.rsc is used by the Select by Attributes tool to save and retrieve sets of selection criteria. The default setting is MS_SELECTBY=$(_USTN_HOMEROOT).
    MS_SELECTSERVICESHOME URL of Bentley SELECTservices homepage.
    MS_SHAREDCONTENTDIR Defines the location of the visualization shared content directory.
    MS_SKETCHUP_IMAGE Stores the texture images that are embedded in the SketchUp files when the SketchUp file is saved as a DGN file.
    MS_SYMBOLPROVIDER_APPS Allows developers to register a managed assembly as an application that provides additional symbols for use in named expressions.
    MS_SYSFONTDIR Directory containing the system fonts.
    MS_TASKMAPFILES Used for internal implementation only.
    MS_TEMPLATEEXTENDER_APPS Used to make terrain model properties available in the Element Templates dialog.
    MS_XATTRIBUTE_HANDLER_LOAD Used to control terrain model elements. This Variablenname should not be changed by users.
    MSDIR_INSTALLED Directory where MicroStation is installed. This configuration Variablenname cannot be modified.
    PWDIR This Variablenname appears only if MicroStation is integrated with ProjectWise and it points to the location of the ProjectWise working directory.




    top

    Erweiterungen (JT-Dateien)

    The following table lists the configuration Variablennames that appear in the Configuration dialog’s Extensions category only when you have a JT file open.

    VariablennameDetailierte Beschreibung
    JTEXPORT_USING_POINT If set to -1, selects the Min. Line Length check box. Variablenname only appears when a JT file has been exported.
    TEXPORT_USING_ANGLE If set to -1, selects the Angle Tolerance check box. Variablenname only appears when a JT file has been exported.
    JTEXPORT_USING_CHORD If set to -1, selects the Chord Tolerance check box. Variablenname only appears when a JT file has been exported.
    JTEXPORT_NESTING_LEVEL Used to set the Reference Nesting Level. Variablenname only appears when a JT file has been exported.
    JTVERSION Used to set the JT version. Variablenname only appears when a JT file has been exported.
    JTEXPORT_BREP By default, JT Interface exports solid and surface data as a kind of mesh data. If this configuration Variablenname is set, the solids and surfaces are exported as B-rep data. Variablenname only appears when a JT file has been exported.
    JTEXPORT_2D_CURVE If set to 1, selects the Export 2D Elements check box. Variablenname only appears when a JT file has been exported.
    JTEXPORT_USED_FACET If set to 1, selects the Use MicroStation Facet check box. Variablenname only appears when a JT file has been exported.
    JTEXPORT_SEWING If set to 1, will stitch adjoining Smart Surfaces and reduce the faceting, thus reducing the file size. It is suggested not to use this configuration Variablenname unless the file contains mainly surface geometry, as it can have a lengthy processing time. Variablenname only appears when a JT file has been exported.
    JTEXPORT_SIMPLIFY If set to 1, will decimate existing meshes, thus reducing the file size. The level of detail will be lower than the original subject, so it is suggested to only use this configuration Variablenname with meshes with very small facets. Variablenname only appears when a JT file has been exported.
    JTEXPORT_BSURFACE If set to 1, selects the Mesh as Set check box. Variablenname only appears when a JT file has been exported.
    JTEXPORT_WITHOUT_PRIMITIVE If set to 1, selects the Facet Primitives check box. Variablenname only appears when a JT file has been exported.
    JTEXPORT_WITHOUT_INSTANCE If set to 1, selects the No Instance check box. Variablenname only appears when a JT file has been exported.
    JTEXPORT_POINT_TOLERANCE Used to set a value for Min. Line Length. Variablenname only appears when a JT file has been exported.
    JTEXPORT_ANGLE_TOLERANCE Used to set a value for Angle Tolerance. Variablenname only appears when a JT file has been exported.
    JTEXPORT_CHORD_TOLERANCE Used to set a value for Chord Tolerance. Variablenname only appears when a JT file has been exported.




    top

    Dateispeicherung

    VariablennameBeschreibungDetailierte Beschreibung
    MS_DGNAUTOSAVE Design File Auto-Save  Legt fest, in welchem Abstand (in Sekunden) eine automatische Speicherung von V8-Dateien stattfindet. Beispielsweise findet bei einem Wert von 2 (0Standardwert) eine automatische Speicherung statt, wenn seit 2 Sekunden keine Eingabe von Seiten des Benutzers erfolgt ist. Mit dem Wert 0 wird die automatische Speicherung deaktiviert.
    MS_V7AUTOSAVE V7 Design File Auto-Save  Legt fest, in welchem Abstand (in Sekunden) eine automatische Speicherung von V7-Dateien stattfindet. Beispielsweise findet bei einem Wert von 300 (Standardwert) etwa 5 Minuten nach der ersten Änderung an der Zeichnung eine automatische Speicherung statt. Der Mindestwert ist 30 Sekunden.
    MS_V7AUTOSAVE_NODIALOG  V7 Auto-Save Dialog im V8-Format. Daher zeigt MiroStation einen Dialog an, in dem der Benutzer den automatischen Speichervorgang aufschieben kann. Wenn diese Konfigurationsvariable definiert ist, wird der Dialog nicht angezeigt und der automatische Speichervorgang findet automatisch statt.
    MS_V7BACKUPV8  V7 create backup in V8 format Wenn diese Variable definiert ist, erstellt $[_USTN_PRODUCT_NAME] bei der Arbeit an einer DGN-Datei im V7-Format jedes Mal, wenn Sie speichern, automatisch eine Backup-Datei im V8-Format. Dies bietet eine Absicherung, falls Sie versehentlich Informationen erstellen, die nicht im V7-Format dargestellt werden können. Diese Variable gibt eine 'Vorlage' an, die zur Erstellung des Namens der Backup-Datei verwendet wird. Wenn Sie den Wert einfach auf 'true' einstellen, wird im selben Verzeichnis wie die Originaldatei eine Datei mit der Erweiterung 'v8' erstellt.
    MS_DWGAUTOSAVE  DWG/DXF File Auto-Save  Legt fest, in welchem Abstand (in Sekunden) eine automatische Speicherung von DWG- und DXF-Dateien stattfindet. Beispielsweise findet bei einem Wert von 300 (Standardwert) etwa 5 Minuten nach der ersten Änderung an der Zeichnung eine automatische Speicherung statt. Der Mindestwert ist 30 Sekunden.
    MS_DWGAUTOSAVE_NODIALOG  DWG/DXF Auto-Save Dialog Dateien im DWG- und DXF-Format benötigen wesentlich länger zum Speichern als Zeichnungsdateien im V8-Format. Daher zeigt MicroStation einen Dialog an, in dem der Benutzer den automatischen Speichervorgang aufschieben kann. Wenn diese Konfigurationsvariable definiert ist, wird der Dialog nicht angezeigt und der automatische Speichervorgang findet automatisch statt.




    top

    Geografische Koordinaten

    The following table lists the configuration Variablennames that affect geographic coordinates. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameDetailierte Beschreibung
    MS_GEOCOORDINATE_DATA Legt den Speicherort für die Katalogdatei des geografischen Koordinatensystems und die Datenumschaltdateien fest.
    MS_GEOCOORDINATE_FAVORITESFILES Gibt die Datei an, die die vom Benutzer in der GKS-Bibliothek ausgewählten Favoriten für das geografische Koordinatensystem enthält.
    You can define multiple files by separating them with semicolons.
    MS_GEOCOORDINATE_REFSETTINGS Gibt das Verzeichnis an, das die Datei mit den Einstellungen für geografische Neuprojektion zur Neuprojektion von Referenzanhängen enthält..
    MS_GEOCOORDINATE_REPROJECTIONSETTINGS Gibt das Verzeichnis an, das die Datei mit den Einstellungen für geografische Neuprojektion zur Neuprojektion von Modelldaten bei Auswahl eines neuen GKS enthält
    MS_GEOCOORDINATE_USERLIBRARIES Gibt die Wörterbuchdateien an, die benutzerdefinierte geografische Koordinatensysteme enthalten. Die Syntax lautet 'FileName1[UIName1]
    This configuration Variablenname is string of the form “LibraryPath1[ShortName1];LibraryPath2[ShortName2]”, where LibraryPath<n> is the file name of the library, and [ShortName<n>] optionally specifies the identifier that appears in the Select Geographic Coordinate System dialog.
    If no directory is specified in LibraryPath, the directory specified by the MS_GEOCOORDINATE_DATA configuration Variablenname is used.




    top

    Ebenen

    MicroStation includes configuration Variablennames to help set up all aspects of the level system.

    The following table lists the configuration Variablennames that affect Levels. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_LEVEL_DISPLAY_FORMAT Level Display Format Legt das bei der Darstellung von Ebenenlisten zu verwendende Format für den Ebenennamen fest.
    N: Ebenennamen verwenden
    D: Ebenenbeschreibung verwenden
    C: Ebenencode verwenden
    Es kann mehr als ein Wert angegeben werden. Beispiel: N(C)
    Standardwert: N
    MS_LEVEL_EDIT_NESTED_ATTACHMENT_LEVELS Edit Nested Attachment Levels Wenn die Variable definiert ist, können Ebenen von verschachtelten Anhängen bearbeitet werden.
    MS_LEVEL_ALLOW_LIBRARY_LEVEL_EDIT Edit Unused Library Levels Ermöglicht die Bearbeitung von Bibliothekebenen, auch wenn diese in der Hauptdatei noch nicht verwendet werden.  Wenn diese Variable nicht gesetzt ist, kann eine Bibliothekebene nur bearbeitet werden, wenn sie verwendet wird, d. h. ein Element darauf platziert ist, was dazu führt, dass die Bibliothekebene in die Hauptdatei kopiert wird.  Ist die Variable gesetzt, kann eine Bibliothekebene, die noch nicht in die Hauptdatei kopiert wurde, bearbeitet werden.  Die Bibliothekebene wird dann bei der Bearbeitung in die Hauptdatei kopiert.
    MS_LEVEL_LOAD_ATTACHMENT_FILTERS Load Attachment Level Filters Wenn diese Variable definiert ist, werden Ebenenfilter von Referenzanhängen geladen.
    MS_LEVEL_EDIT_ATTRIBUTE_LIST Control Level Attributes Edit Diese Variable steuert eine Liste von bearbeitbaren Referenz- bzw. Bibliothekebenen. In einer durch Komma getrennten Liste können ein oder mehrere der folgenden Attribute enthalten sein: OverrideSymbology, OverrideColor, OverrideStyle, OverrideWeight, OverrideMaterial, ByLevelSymbology, ByLevelColor, ByLevelStyle, ByLevelWeight, ByLevelMaterial, GlobalDisplay, GlobalFreeze, DisplayPriority, Transparency, Lock, Plot. Jedes der oben genannten Attribute kann das Präfix "Reference" oder "Library" übernehmen. Ist kein Präfix vorhanden, wird das besagte Attribut sowohl für Referenz- als auch für Bibliothekebenen bearbeitbar. Der Attributsliste kann durch ein Komma getrennt entweder "+" oder "-" vorangestellt werden, um die anfängliche Standardeinstellung inkrementell zu ändern.
    MS_LEVEL_SYNC_ATTRIBUTE_LIST Control Level Attributes Synch Wirkt sich auf die Eingaben "DGNLIB UPDATE LEVELS CUSTOM" und "REFERENCE SYNCHRONIZE LEVELS CUSTOM" aus. Diese Variable steuert die Liste der Ebenenattribute, die bei der Ausführung einer der o. g. Eingaben synchronisiert werden. In einer durch Komma getrennten Liste können ein oder mehrere der folgenden Attribute enthalten sein: OverrideSymbology, OverrideColor, OverrideStyle, OverrideWeight, OverrideMaterial, ByLevelSymbology, ByLevelColor, ByLevelStyle, ByLevelWeight, ByLevelMaterial, GlobalDisplay, GlobalFreeze, DisplayPriority, Transparency, Lock, Plot. Jedes der oben genannten Attribute kann das Präfix "Reference" oder "Library" übernehmen. Ist kein Präfix vorhanden, wird das besagte Attribut sowohl für Referenz- als auch für Bibliothekebenen synchronisiert. Der Attributsliste kann durch ein Komma getrennt entweder "+" oder "-" vorangestellt werden, um die anfängliche Standardeinstellung inkrementell zu ändern.
    MS_LEVEL_SYNCH_BYLEVEL Synch Symbology to ByLevel on Level Change Wenn aktiviert, werden die aktive Farbe, die aktive Strichstärke und der aktive Stil auf "ByLevel" gesetzt, wenn die aktive Ebene geändert wird oder ein neues Modell oder eine neue Ansichtsgruppe geöffnet wird.

    If set, when you open a different model or view group, the active color, line style, and line weight are set to ByLevel.
    The cases in which you open a different model or view group include:
    • opening a different file
    • opening the Models dialog and double-clicking a different model
    • exchanging a reference
    • selecting a different view group from the View Groups window
    • clicking the Previous Model or Next Model icons in the View Groups window
    MS_LEVEL_AUTO_SYNC_ATTRIBUTE_LIST Level Attribute Auto Synch. Diese Variable steuert die Liste der Ebenenattribute, die beim Öffnen einer Datei automatisch synchronisiert werden. In einer durch Komma getrennten Liste können ein oder mehrere der folgenden Attribute enthalten sein: OverrideSymbology, OverrideColor, OverrideStyle, OverrideWeight, OverrideMaterial, ByLevelSymbology, ByLevelColor, ByLevelStyle, ByLevelWeight, ByLevelMaterial, GlobalDisplay, GlobalFreeze, DisplayPriority, Transparency, Lock, Plot. Jedes der oben genannten Attribute kann das Präfix "Reference" oder "Library" übernehmen. Ist kein Präfix vorhanden, wird das besagte Attribut sowohl für Referenz- als auch für Bibliothekebenen synchronisiert. Der Attributsliste kann durch ein Komma getrennt entweder "+" oder "-" vorangestellt werden, um die anfängliche Standardeinstellung inkrementell zu ändern.
    MS_LEVEL_SEED_LEVEL_NAME Seed Level Name Wenn diese Variable definiert ist, gibt sie den Namen der Seed-Ebene an. Eine neue Ebene übernimmt ihre Eigenschaften aus der Seed-Ebene. Wenn die Variable nicht definiert ist, handelt es sich bei der Seed-Ebene um die Standardebene.
    MS_LEVEL_CREATE_FROM_SEED_ATTRIBUTE_LIST Seed Level Attributes to use Diese Variable steuert die Liste der Ebenenattribute, die aus der Seed-Ebene kopiert werden (MS_REF_REATTACH_LEVEL_SYNC_ATTRIBUTE_LIST). In einer durch Komma getrennten Liste können ein oder mehrere der folgenden Attribute enthalten sein: Description, OverrideSymbology, OverrideColor, OverrideStyle, OverrideWeight, OverrideMaterial, ByLevelSymbology, ByLevelColor, ByLevelStyle, ByLevelWeight, ByLevelMaterial, GlobalDisplay, GlobalFreeze, DisplayPriority, Transparency, Lock, Plot. Der Attributsliste kann durch ein Komma getrennt entweder "+" oder "-" vorangestellt werden, um die anfängliche Standardeinstellung inkrementell zu ändern.
    MS_UPDATE_KEEP_UNUSED_LIBRARY_LEVELS Keep Unused Library Levels Bestimmt, ob nicht verwendete Bibliotheksebenen bei der Ausgabe des Befehls "dgnlib update levels" beibehalten oder gelöscht werden. Wird diese Variable nicht eingestellt oder auf "0" gesetzt, dann werden nicht verwendete Bibliotheksebenen bei der Ausführung des Befehls "dgnlib update levels" entfernt. Wenn die Variable auf "1" gesetzt ist, werden nicht verwendete Bibliotheksebenen beibehalten. Wenn für die Variable "2" eingestellt ist, werden nicht verwendete Bibliotheksebenen, deren Attribute übereinstimmen, gelöscht.
    MS_LEVEL_PICKER_WIDTH Attributes Level Picker Width Legt die Breite (in Pixel) des Ebenenauswahlfeldes im Toolbox-Rahmen 'Attribute' fest.
    MS_REF_REATTACH_LEVEL_SYNC_ATTRIBUTE_LIST Ref. Reattach Level Attributes Specifies the list of level attributes that will sync when a reference is reattached. The attributes can be one or more of the following as a comma separated list: OverrideSymbology, OverrideColor, OverrideStyle, OverrideWeight, ByLevelSymbology, ByLevelColor, ByLevelStyle, ByLevelWeight, GlobalDisplay, GlobalFreeze, DisplayPriority, Transparency, and Plot.
    MS_LEVEL_LIB_DIR Level Library Path Verzeichnis mit Dateien für Ebenen-Datendateien.
    Defines the default directory to look for when exporting levels or importing levels to/from a CSV, DGN, or DGNLib file.
    MS_V7TOV8_CSVNAME V7 to V8 Level CSV File CSV-Datei, die steuert, wie Ebenen zugeordnet werden, wenn eine V7-Datei in V8 konvertiert wird.
    MS_V7_LEVEL_NAME_PREFIX V7 to V8 Level Name Prefix Präfix, der unbenannten Ebenen zugewiesen werden soll, wenn eine V7-Datei in V8 konvertiert wird.
    MS_V7TOV8_DELETE_UNUSED_LEVELS V7 to V8 Delete Unused Levels Wenn diese Variable auf 1 gesetzt ist, werden alle nicht genutzten Ebenen gelöscht, wenn eine V7-Datei in V8 konvertiert wird. Diese Variable wird ignoriert, wenn die Variable "CSV-Ebenendatei für V7 auf V8-Aktualisierungen (MS_V7TOV8_CSVNAME)" gesetzt ist.




    top

    Makro Rekorder

    The following table lists the configuration Variablennamesthat affect the Bentley Macro Recorder. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_MACRO Makros Liste der Pfade, in denen nach BMR-Makros und VBA-Projekten gesucht werden soll.
    MS_MACRONEWFILEDIRECTORY Makros Standardpfad zum Speichern neuer Makros. Dies muss ein einzelnes Verzeichnis sein.
    MS_VBAAUTOLOADPROJECTS Markup Template Sheet Namen der Projekte, die beim Aufruf der Dialog VBA geöffnet werden.
    MS_VBANEWPROJECTDIRECTORY Markup Template File Verzeichnis, das bei Erstellung eines neues Projekts verwendet wird.
    MS_VBASAVEONRUN Markup Customization Settings Wenn diese Variable auf 1 gesetzt ist, speichert $[_USTN_PRODUCT_NAME] automatisch alle geänderten VBA-Projekte beim Ausführungsstart eines VBA-Programms.
    MS_VBASEARCHDIRECTORIES Markup Path Verzeichnise, die beim Öffnen eines vorhandenen VBA-Projekts durchsucht werden.




    top

    Markup

    There are configuration Variablennames available to specify markup-related directory paths, page layout and resolution.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_MARKUP_HIDE_AUDIT_COMMENTS Hide Markup Audit Comments Ausblenden der Markupprüfungskommentare. When set to True, audit comments do not display in the Comment section of the Markups dialog. However, user comments continue to display.
    MS_MARKUPVIEWRESOLUTION Markup View Resolution Markupansichtsauflösung. Sets the resolution of the Markup View window, which is used to view a markup. Resolution can be set between 200 and 1200; default is 500.
    MS_MARKUPSHEETSEEDNAME Markup Template Sheet Vorlagenblatt, das zum Erstellen der Markup-Blätter verwendet wird. Specifies the default page layout size. The default is Letter (Landscape).
    MS_MARKUPSHEETSEED Markup Template File Vorlagendatei, die zum Erstellen der Markup-Blätter verwendet wird. Sets the directory path for the location of the template file (Page Layout File) when creating markup sheets.
    MS_MARKUPSETTINGS Markup Customization Settings Benutzerdefinierte Markup-Einstellungen. Sets the location of the file that controls the settings for markups. The default is $(MS_DATA)MarkupConfig.XML.
    MS_MARKUPPATH Markup Path Suchpfad für Markups. Sets the directory path for the location where the markups are saved.




    top

    OLE

    VariablennameBeschreibungDetailierte Beschreibung
    MS_OLE_RETAIN_CONTROL_SIZE Retain display size of object Wenn der Wert 1 eingestellt ist, wird die Darstellungsgröße des OLE-Objekts beibehalten. Andernfalls wird die vom OLE-Server gemeldete Änderung übernommen.
    MS_OLESERVE_EMBED_REFFILES Embed References Ist diese Option festgelegt, werden Referenzen zusammen mit der Haupt-DGN-Datei eingebettet.




    top

    Operation

    The following table lists the configuration Variablennames that affect Operation. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_APPMEN Application Menus Location of application and sidebar menus.
    MS_AUTORESTORESTATUSBAR Auto-restore Status Bar If set to 1, the status bar is restored to its default appearance whenever the pointer is moved within.
    MS_AUTOUPDATETEXTITEMSSLOWER AutoUpdate speed for Text items Slows down the AutoUpdate timer for text items. If set to 1, and if MS_AUTOUPDATETEXTITEMSSUPPORT is set to 1, text items are automatically synchronized with their values at a slower rate.
    MS_AUTOUPDATETEXTITEMSSUPPORT AutoUpdate feature for Text items Turns the AutoUpdate feature on for text items on those dialogs and tool settings that want this feature. "Text items" are text controls or text input fields on dialogs and tool settings windows. If set to 1, text items are automatically synchronized with their values without focusing out. For example, while placing a circle, in the Place Circle tool settings window, if you enter a value in the Diameter text field, the cursor displays the circle with that diameter. If you change the diameter in the text field, the size of the circle changes to the new value automatically.
    MS_COMMONITEMDIALOG Common Item Dialog from Microsoft By default, the newer Common Item Dialog from Microsoft is used for most file open/save dialogs. If the older Microsoft file dialogs are preferred at all times, set this Variablenname to 0.
    MS_COMPRESS_OPTIONS Compress Options Selections Specifies file compression options. If set, the specified options override the selections in the Compress Options dialog.
    MS_CURSORPROMPT Cursor Prompt If set to 1, displays a Cursor Prompt window that follows the mouse. The cursor prompt shows the message displayed in the lower left field of the Status Bar. It guides you step by step as you perform an operation with a tool.
    MS_DEFAULT_MAINTASKPATH Default Main Task Overrides the default Main task. The Main task is now driven by 'Main Task' definitions in DGNLIB's. To upgrade, migrate your existing toolbox definition to a Main task, and set this configuration appropriately.
    MS_DISABLE_FILE_ICONS Disable File Open Icons If set, the Show File Icons check box is not shown in the File Open, New, and Open dialogs. Also, the setting is turned off thereby preventing the display of file list icons. The effect is not evident until you restart MicroStation.
    MS_DISABLE_FILE_THUMBNAIL Disable File Open Thumbnail If set, thumbnail images of files are not displayed in the File Open and Open dialogs.
    MS_FILEHISTORY File History If set, MicroStation saves the last four files and directories for each file type.
    MS_FKEYMNU Function Key Menu Defines the file name for the default function key menu. The default name is "funckey.mnu" located in the MS_DATA directory. When you create or modify a function key menu, the default function key menu acts as a seed for modification.
    MS_FULLPATHINTITLEBAR Full Path in Title Bar If set, the full file specification of the open file, including path, is displayed in the MicroStation application window title bar.
    MS_GRAYGROUPHEADERBACKGROUND Gray Color for Group Headers By default, the background color of selected Group Headers is blue. "Group Headers" are headers of groups/sections in dialogs like Explorer dialog and Properties dialog. If set to 1, a gray color is used.
    MS_GROUPPOPUPFADEKEYTIPS Ribbon Group Popup Fade KeyTips Not used.
    MS_GROUPPOPUPFALLBACKWORKFLOW_2D Fall-back Workflow for pop-up group processing. Defines the workflow to use when the pop-up group path starts with a "*" and the active workflow does not contain the specified group and the active model is 2D.
    MS_GROUPPOPUPFALLBACKWORKFLOW_3D Fall-back Workflow for pop-up group processing. Defines the workflow to use when the pop-up group path starts with a "*" and the active workflow does not contain the specified group and the active model is to be treated as 3D.
    MS_IDLETIMEOUT Exit MicroStation When Idle If set, specifies the number of minutes of inactivity to wait before exiting an active session of MicroStation. (“Active session” means that a DGN file is open.) The minimum value is 30 minutes.
    MS_IMMEDIATEUPDATE Window Immediate Update If set, view windows will immediately update when other windows are moved or resized over them.
    MS_INPUT_CONFIGXML Default Touch Gesture Configuration Directory containing the inputconfiguration.xml file, which is used to store gesture assignments.
    MS_KEYBOARDSHORTCUTS User Keyboard Shortcuts XML file containing user keyboard shortcuts.
    MS_KEYBOARDSHORTCUTSEXPAND Keyboard Shortcuts User Order If set to 1, the parent nodes will be expanded when the Keyboard Shortcuts dialog is opened. A value of 0 is the default.
    MS_KEYBOARDSHORTCUTSSEED Default Keyboard Shortcuts XML file containing default keyboard shortcuts. This file is used to define keyboard shortcuts if the file defined by MS_KEYBOARDSHORTCUTS is not found.
    MS_KEYBOARDSHORTCUTSUSERORDER Keyboard Shortcuts User Order If set to 1 (the default), the order of the Keyboard Shortcuts in the menu will be the order set by the user.
    MS_LEGACYTOOLMAPLIST Path to files that contain Tool Mapping data Defines list of Tool Map XML files that specify mapping of tools from MicroStation V8i to the current version.
    MS_LIBRARY_SAVEDVIEW_FILTER Saved Views Library Filter Specifies a set of saved views to exclude from the user interface. The filter is applied only to views found in libraries. For filter syntax and string expressions, see Defining and Deleting Filters.
    MS_MAINMENUDOCKINGBESIDE Allow Docking Beside Main Menu If set to 0 or not set (default), the main menu bar spans the entire width of the application window. If set to a value other than zero, toolboxes and dockable dialogs can be docked along the main menu bar.
    MS_NO_VIEW_ANIMATION Disable Tile/Cascade Animation If on, the animation of view tile and cascade is disabled.
    MS_OPENDWGAEC Open DWG AEC files Controls the behavior when opening DWG AEC files of an older version:
    • Value = 1 - The file is opened for editing and the AEC objects are upgraded to the current version.
    • Value = 2 - The file is opened as read-only.
    • Value = null - If not set at all or set to any other value, the Alert window opens.
    MS_OPENV7 Open V7 Files Controls MicroStation's behavior when opening V7-format design files. If not set or set to 0, the file opens with an alert dialog that provides an option to upgrade the file to V8 DGN format. If set to 1, the file is upgraded to V8 DGN format and opened. If set to 2, the file is opened in read-only mode. If set to 3, the file is opened in V7 workmode.
    MS_POPUPDIALOGCLOSEDELAY Popup Dialog Close Delay Specifies the time, in milliseconds, to wait before closing a pop-up dialog. The valid range is 0-120 (0-2 seconds). The default value is 30 (0.5 seconds).
    MS_READONLY Read Only If set, the active DGN file is read-only.
    MS_RIBBONCOMPONENTPROVIDERS Ribbon Component Providers AddIn List List of managed addins that provide their own ribbon content. For example, Baseribbon.cfg file contains an entry for Bentley.Macros.UI.dll. Adding this provides support for the "Macros" ribbon group.
    MS_RIBBONDIR Base Path for Ribbon Definitions Base path where ribbon definitions are located. This path is not used directly but is typically used to define MS_RIBBONRSC, MS_RIBBONXML.
    MS_RIBBONPREFS Ribbon Preferences File Specifies the name of the file containing the current state of the ribbon, such as the active workflow, active tab, and setting for ribbon search.
    MS_RIBBONPREFSSEED Ribbon Preferences Seed File Specifies the seed file for the ribbon preferences file, if not defined for MS_RIBBONPREFS. The file specified by MS_RIBBONPREFSSEED is only used to create the file specified by MS_RIBBONPREFS when that file is not present. This typically only happens when the product is first loaded or when a user has used the command line option -restoredefaults.
    MS_RIBBONRSCLIST Ribbon Resource File List Specifies a list of RSC files containing ribbon components definitions.
    MS_RIBBONXML Ribbon XML File List Specifies a list of XML files containing ribbon components definitions.
    MS_RIBBON_MAXBUTTONLABELCHARS Maximum characters for a ribbon label Specifies the maximum number of characters to display for a ribbon button label. If not set, the default value is 24. The minimum value is 20. The maximum value is 128.
    MS_RIBBON_NUMEXPANDEDTASKGROUPS Number of Expanded groups on Active Task tab Specifies the number of expanded groups in a task tab. Once this limit is hit then all other tasks are placed in an Overflow group.
    MS_SAVEMENU Attached Menus File containing information about attached menus.
    MS_SOURCENAME_PROPERTY Save the SOURCE file property If set, the SOURCE file property can be set to the name of the source file. By default, only the name and extension of the source file are saved. Set to 0 to disable the SOURCE property. Set to FULL to save the full path of the source file.
    MS_TOOLSETTINGSIGNORETITLEFORWIDTH Tool Settings Ignore Title when Determining Width Is set to 1, the title of the tool settings is ignored when determining the width of the tool settings window.
    MS_UPDATESPLITBUTTONLABELTOSELECTED Update Split Button Label to Selected If set to 1, enables updating the label of a split button to match the selected child item. By default, only the image and tooltip are updated. If this option is enabled, the split button, as well as the ribbon groups, will grow and shrink based on the size of the label.
    MS_VIEWAUTORESIZE View Resize Behavior If set to 1, the view windows are resized proportionally when the main window is resized or when the dialogs are docked or undocked.
    If set to 0, the view window resizes only when the main window border encroaches the view window border.
    MS_VIEWTOOLBOX2D View window toolbox for 2D Overrides for the View window toolboxes for 2D. The value can be the title of a system toolbox or user-defined toolbox.
    MS_VIEWTOOLBOX3D View window toolbox for 3D Overrides for the View window toolboxes for 3D. The value can be the title of a system toolbox or user-defined toolbox.
    MS_WORKMODE Work Mode Workmode activates/disables certain functions in order to produce a more compatible design at the end. Setting this Variablenname to DWG will disable some creation tools that may result in elements that are incompatible with the DWG file format. Setting it to DGN (default) will gain full functional capacity in creating elements. You must restart MicroStation to see the effect of a changed value.
    MS_WORKSPACEOPTS Workspace Options (Applicable only to the old File Open dialog (MicroStation Manager)) If set to 0 (default), the Workspace options are displayed on the File Open dialog. If set to 1, the Workspace options are displayed but disabled. If set to 2, the Workspace options are hidden and the dialog box is resized.




    top

    Punktwolke

    VariablennameBeschreibungDetailierte Beschreibung
    MS_POINTCLOUD_LAS_NBIT_COLOR Point Cloud LAS File Color treatment  Ist diese Variable definiert und auf 8 gesetzt, werden Farben mit 8 Bit verwendet. Ist 16 eingestellt, werden 16 Bit verwendet
    Ist diese Variable nicht definiert oder auf einen anderen Wert gesetzt, wird versucht, die Bit-Anzahl über den Farbkanal automatisch zu ermitteln.




    top

    Hauptsuchpfade

    The following table lists the configuration Variablennames that affect Primary Search Paths. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    DWGRDL_DIR DWG Redline Location Definiert den Speicherort und/oder Dateinamenanhang der von Bentley Redline generierten DWG-Redline-Datei, nach der die Funktion 'Redline ein' sucht. Standardmäßig ist dies <AktiverDateiname>_redline.dwg im selben Verzeichnis wie die aktive DWG-Datei.
    MS_ADDINPATH AddIns Suchpfad für verwaltete Add-In-Baugruppen, die außerhalb der $[_USTN_PRODUCT_NAME]-Anwendungsbasis oder des konfigurierten privatePath eingesetzt werden.
    MS_ADDIN_DEPENDENCYPATH AddIn Dependencies Suchpfad für verwaltete Baugruppen, die von Add-Ins verwendet werden und die außerhalb der $[_USTN_PRODUCT_NAME]-Anwendungsbasis oder des konfigurierten privatePath eingesetzt werden. Verzeichnisse sollten normalerweise nicht sowohl hier als auch in MS_ADDINPATH aufgelistet werden.
    MS_DEF Design Files Suchpfad(e) für Zeichnungsdateien.
    MS_DGNLIBLIST DGN Library List Liste der DGN-Bibliotheksdateien, die zum Auffinden von Ebenen, Stricharten, Textstilen, Bemaßungsstilen, Multilinienstilen, Elementvorlagen, Textfavoriten, Tabellenstilen, Berichtsdefinitionen, Zeichnungs-Seeds, Zeichnungsumrandungen, Darstellungsstilen, Darstellungsregeln, Seitenlayouts, Fest-Ansichten und Objekttypen für Ihre aktuelle Sitzung verwendet werden.
    MS_DGNLIBLIST_LINKS DGN Library List Liste der DGN-Bibliotheksdateien, die zum Auffinden von Verknüpfungsgruppen für Ihre aktuelle Sitzung verwendet werden.
    MS_DGNLIBLIST_PRINTING DGN Library List Liste der DGN-Bibliotheksdateien, die zum Auffinden von Druckstilen für Ihre aktuelle Sitzung verwendet werden.
    MS_DGNLIBLIST_RENDER DGN Library List Liste der DGN-Bibliotheksdateien, die zum Auffinden von Rendering-Setups, Materialien und Lichtquellen für Ihre aktuelle Sitzung verwendet werden.
    MS_DISPLAYSTYLE_LIBLIST Display Style Library Include Filter Search path for library files to list display styles. This configuration Variablenname should point only to those files that are specified in the MS_DGNLIBLIST configuration Variablenname. If this configuration Variablenname is not defined, the display styles in all the files pointed by MS_DGNLIBLIST are listed.
    MS_ECFRAMEWORK_SCHEMAS ECSchema Search Path Ein Pfad für die Suche nach ECSchemas (Bibliotheken von Elementetypen), die den Engineering-Inhalt definieren. This Variablenname should not be changed by users.
    MS_FILTER_LIB_DIR Filter Library Path Verzeichnis mit Dateien für Filter-Datendateien.
    MS_GUIDGNLIBLIST User Interface DGN Library List Liste der DGN-Dateien, in der Funktions-, Tasks- und Menüanpassungen für Ihre aktuelle Sitzung gespeichert werden.
    MS_ICONLIBRARYLIST Icon Library List Suchpfad für Windows DLL-Dateien, die Windows ICO-Ressourcen enthalten.
    MS_ICONPATH Icon Path Suchpfad für Windows ICO-Dateien.
    MS_ICONRSCLIST Icon Resource File List Suchpfad für MicroStation-Ressourcendateien, die Windows ICO-Ressourcen enthalten.
    MS_LIBRARY_PATH Library Path Suchpfad(e) für dynamic link libraries.
    MS_LINFILELIST LIN File Path Verzeichnis mit LIN-Strichartdateien. Diese Stricharten werden nach Bedarf in die DGN-Dateien kopiert.
    MS_MDL MDL Applications Suchpfad(e) für MDL-Applikationen oder externe Programme, die von MDL-Applikationen geladen wurden.
    MS_MDLAPPS Visible MDL Applications Suchpfad(e) für MDL-Applikationen, die in der MDL-Dialog dargestellt werden.
    MS_PERSONALDGNLIB Users Personal DGNLib Persönliche DGNLIB-Dateien dienen der Speicher von benutzerdefinierten Anpassungen.
    MS_RFDIR References Suchpfad(e) für Referenzen.
    MS_RSRCPATH Resource Files Suchpfad(e) für Ressourcen-Dateien, die von MDL-Applikationen geladen wurden.
    MS_SAVEDVIEW_EXCLUDELIBS Saved Views Library Exclude Filter The saved views in the library files pointed by this configuration Variablenname are not displayed in the Saved Views dialog. This configuration Variablenname should point only to those files that are specified in the MS_DGNLIBLIST configuration Variablenname. If this configuration Variablenname is not defined, the saved views of all the files pointed by MS_DGNLIBLIST are displayed in the Saved Views dialog.
    MS_SEED_LINKSET_PATH Link Set Seed File Path Suchpfad für die durch MS_SEED_LINKSET_NAME definierte Verknüpfungsgruppen-Seed-Datei.
    RDL_DIR Redline Location Definiert den Speicherort und/oder die Erweiterung der von Bentley Redline generierten Redline-Datei, nach der die Funktion 'Redline ein' sucht. Standardmäßig ist dies <AktiverDateiname>.rdl im selben Verzeichnis wie die aktive DGN-Datei.




    top

    Drucken

    MicroStation includes configuration Variablennames to help set up all aspects of the printing process.

    The following table lists the configuration Variablennames that affect the printing operations. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_PLTCFG_PATH Printer Driver Config Path legt den Suchpfad für die Druckertreiber-Konfigurationsdateien  (.pltcfg oder .plt) fest. Dieser Pfad dient außerdem zum Lokalisieren von verwandten Dateien wie  z. B. PostScript-Prologdateien.
    This path is also used to locate dependent files such as PostScript prolog files, which are no longer constrained to the same directory as the selected .pltcfg or .plt files. They can be stored anywhere in MS_PLTCFG_PATH. If the MS_PLTCFG_PATH configuration Variablenname is defined, the first directory in its value is used as the initial directory in the Select Printer Driver Configuration File dialog. Otherwise, the most recently used directory for printer driver configuration files is used.
    MS_DEFAULT_PLTCFG_FILE Default Printer Configuration Wenn MS_DEFAULT_PLTCFG_FILE auf den Dateinamen einer Druckertreiberkonfiguration eingestellt ist, wird  diese Datei (anstelle der zuletzt verwendeten) beim Öffnen des Druckdialogs verwendet.  Der Wert dieser Variable kann eine .pltcfg- oder eine .plt-Datei sein.
    This Variablenname replaces the old Variablenname MS_PLOTDLG_DEF_PLTFILE. The old Variablenname is still honored if MS_DEFAULT_PLTCFG_FILE is not defined.
    MS_PLT_SYSPRT_PLTFILE Default Windows Printer Driver Wenn für MS_PLT_SYSPRT_PLTFILE der Name einer Druckertreiberkonfigurationsdatei angegeben ist, wird diese anstelle der im Lieferumfang enthaltenen Datei 'printer.pltcfg' als Standard-Windows-Druckertreiberkonfiguration verwendet.
    MS_PLT_PDF_PLTFILE Default PDF Printer Name Wenn für MS_PLT_PDF_PLTFILE der Name einer Druckertreiberkonfigurationsdatei angegeben ist, wird diese anstelle der im Lieferumfang enthaltenen Datei 'pdf.pltcfg' als Standard-PDF-Druckertreiberkonfiguration verwendet.
    MS_PLT_SYSPRT_DEFAULT_PRINTER Default Windows Printer Name Mit MS_PLT_SYSPRT_DEFAULT_PRINTER können Sie den Namen des Druckers angeben, der  beim Öffnen eines Standard-Systemdruckers ausgewählt wird.
    MS_PLT_SYSPRT_DEFAULT_FORM Default Windows Form Name Mit dieser Variablen können Sie den Namen des Formats angeben, das  beim Öffnen eines Standard-Systemdruckers ausgewählt wird.
    MS_PLT_SYSPRT_DEFAULT_TRAY Default Windows Tray Name Mit MS_PLT_SYSPRT_DEFAULT_TRAY können Sie den Namen des Fachs angeben, das  beim Öffnen eines Standard-Systemdruckers ausgewählt wird.
    MS_PLTFILES Print Output Directory MS_PLTFILES legt das Ausgabeverzeichnis für Druckdateien fest.
    The print output directory specified by this configuration Variablenname is now given priority over the most recently used print output directory. If this configuration Variablenname is defined, the most recently used directory is always ignored when the Print dialog brings up the Save Print As dialog for saving a print output file.
    MS_PRINTDEF_PATH Print Definition Search Path MS_PRINTDEF_PATH legt den Suchpfad für gespeicherte Druckdefinitionsdateien (.pset und .ini) fest.
    MS_PENTABLE Pen Table Search Path Suchpfad für Plotkonventionsdateien.
    MS_PENTABLE_EDITOR Pen Table Editor Ist hier 'HIDE_MENU_ITEM' eingestellt, wird die Menüoption 'Plotkonventionen bearbeiten' im Druckdialog nicht angezeigt.
    MS_DESIGNSCRIPT_EDITOR Design Script Editor Vollständig qualifizierter Name eines Texteditors, der verwendet werden soll, wenn im Druckdialog die Menüoption 'Designskript bearbeiten' aktiviert wird. Legen Sie als Wert beispielsweise 'notepad.exe' (ohne Anführungszeichen) fest, um den Editor von Windows als Texteditor zu verwenden.  Wenn diese Variable nicht definiert ist, wird der Windows-Editor verwendet.
    Ist hier 'HIDE_MENU-ITEM' festgelegt, wird die Menüoption 'Designskript bearbeiten' im Druckdialog nicht angezeigt.
    MS_DESIGNSCRIPT_PATH Design Script Search Path Suchpfad für Designskriptdateien. Ohne Festlegung wird MS_PENTABLE verwendet.
    MS_PLT_PREVIEW_USABLEAREACOLOR Preview Usable Area Color gibt die Farbe des Rechtecks für den nutzbaren Bereich im Vorschaufenster des Druckdialogs für den Einzeldruck an. Bei '0' wird das Rechteck nicht gezeichnet. Zulässige Werte finden Sie in der Beschreibung zu MS_PENTABLE_DISABLECOLOR.
    MS_PLT_PREVIEW_PLOTBOXCOLOR Preview Plot Rectangle Color gibt die Farbe des Druckbegrenzungsrechtecks im Vorschaufenster des Druckdialogs für den Einzeldruck an. Bei '0' wird das Rechteck nicht gezeichnet. Zulässige Werte finden Sie in der Beschreibung zu MS_PENTABLE_DISABLECOLOR.
    MS_PLT_PREVIEW_PLOTFENCECOLOR Preview Plot Fence Color gibt die Farbe der Druckzaun-Polygonfläche im Vorschaufenster des Druckdialogs für den Einzeldruck an. Bei '0' wird die Polygonfläche nicht gezeichnet. Zulässige Werte finden Sie in der Beschreibung zu MS_PENTABLE_DISABLECOLOR.
    MS_PLTDLG_UNLOADONCLOSE Unload Plot Dialog on Close Steuert, ob der Druckdialog beim Schließen des Fensters entladen wird.  Wenn der Wert '1' oder nicht definiert ist, wird die Druckdialog-Applikation automatisch geschlossen
    MS_PLTDLG_CLOSE_AFTER_PLOT Close Print Dialog After Plot Wenn MS_PLTDLG_CLOSE_AFTER_PLOT auf '1' eingestellt ist, wird der Druckdialog  nach erfolgreicher Ausführung des Plotauftrags automatisch geschlossen. Standardmäßig  bleibt der Druckdialog nach einem Plot weiterhin geöffnet.
    MS_PLT_ENABLE_SCALE_CLIPPING Enable Scale Clipping Wenn MS_PLT_ENABLE_SCALE_CLIPPING auf '0' eingestellt ist, reduziert der Druckdialog nicht den Plotzaun oder die Blattgröße, um dem benutzer- oder blattspezifischen Skalierungsfaktor gerecht zu werden.
    MS_PLT_ENABLE_PRESERVE_SCALE Enable Preserve Scale Wenn MS_PLT_ENABLE_PRESERVE_SCALE auf '0' eingestellt ist, versucht der Druckdialog nicht, die aktuelle Plotskalierung zu bewahren, wenn eine neue Ansicht, ein neuer Zaun oder eine neues Papierformat gewählt wird.
    MS_PLT_ENABLE_AUTO_ROTATE Enable Automatic Rotation Wenn MS_PLT_ENABLE_AUTO_ROTATE auf '0' gesetzt ist, ändert der Druckdialog nicht automatisch die Plotdrehung, um eine optimale Einpassung zu erzielen.  Diese Variable gilt nur für Bentley-Plottertreiber.
    MS_PLT_ENABLE_AUTO_ORIENT Enable Automatic Orientation Wenn MS_PLT_ENABLE_AUTO_ORIENT auf '0' gesetzt ist, ändert der Druckdialog nicht automatisch die Papierausrichtung, um eine optimale  Einpassung zu erzielen. Diese Variable gilt nur für Systemdrucker.
    MS_PLTDLG_AREA_PRIORITY Print Area Priority Wenn MS_PLTDLG_AREA_PRIORITY auf '1' eingestellt ist, haben Blattdefinitionen im Modell Vorrang vor dem aktiven Zaun.  Neue Zäune werden ignoriert, wenn der Druckbereich auf den Modus 'Blatt' eingestellt ist.  Dies ist die Standardeinstellung. Wenn diese Variable auf '2' eingestellt wird, hat der aktive Zaun Priorität vor Blattdefinitionen.
    MS_PLT_FORM_SCALE_PRIORITY Form Scale Priority Wenn MS_PLT_FORM_SCALE_PRIORITY auf '1' eingestellt ist, wird die  in der Druckertreiberkonfiguration angegebene Standard-Formatskalierung, wird jedes Mal erneut zugewiesen,  wenn sich das Papierformat ändert. Standardmäßig wird die aktuelle Druckskalierung bewahren.
    MS_PLT_SET_LAYOUT_FROM_SHEET Honor Sheet Layout Info Wenn MS_PLT_SET_LAYOUT_FROM_SHEET auf '0' eingestellt ist, wird das Druckdialog-Layout nicht automatisch eingestellt, wenn eine Blattdefinition geladen ist (und der aktuelle Druckmodus 'Blatt' ist). Die Blatt-Layoutinformationen werden standardmäßig berücksichtigt.
    MS_PLT_SET_PLOT_STYLE_TABLE_FROM_SHEET Honor Sheet Plot Style Table Standardmäßig wird jede in der Blattdefinition angegebene Plotzuordnungstabelle automatisch an den Plot angehängt. Wenn MS_PLT_SET_PLOT_STYLE_TABLE_FROM_SHEET auf '0' eingestellt ist, werden die Plotzuordnungstabellen aus der Blattdefinition ignoriert.
    MS_PLT_MAX_ON_NEW_AREA Maximize on New Print Area Wenn MS_PLT_MAX_ON_NEW_AREA auf '1' eingestellt ist, wird die  Druckgröße bei Ändern des Druckbereichs automatisch maximiert. Dies  gilt auch bei Auswahl einer Ansichtsnummer oder Platzierung eines Zauns.  Standardmäßig wird die aktuelle Druckskalierung bewahren.
    MS_PLTDLG_AUTO_FIT_VIEW Automatically Fit View Wenn MS_PLTDLG_AUTO_FIT_VIEW auf '1' oder '2' gesetzt ist, stellt der Druckdialog den Druckbereichsmodus beim ersten Aufruf automatisch auf 'Zaun' ein.  Mit einem Wert von '1' wird ein Zaun erstellt, der alle Elemente in der Masterdatei umfasst. Mit einem Wert von '2' wird ein Zaun erstellt, der alle Elemente in der Masterdatei sowie all ihre Referenzen umfasst. Wenn bei Aufrufen des Druckdialogs ein aktiver Zaun oder ein aktives Blatt definiert wird, wird diese Konfigurationsvariable ignoriert.
    MS_PLTDLG_SHOW_BASIC_LAYOUT_CONTROLS Basic Layout Controls Wenn MS_PLTDLG_SHOW_BASIC_LAYOUT_CONTROLS auf '1' eingestellt ist, werden  die Steuerungen für beliebige Plotdrehung und Spiegeln ausgeblendet. Stattdessen wird der Optionsschalter für die Plotdrehung angezeigt.
    MS_PLTDLG_ALLOW_FORM_SIZE_EDIT Allow Form Size Edits Wenn MS_PLTDLG_ALLOW_FORM_SIZE_EDIT auf '1' eingestellt ist, kann die Größe des  ausgewählten Formats über den Druckdialog geändert werden. Diese Einstellung gilt nicht für Systemdrucker.
    MS_PLTDLG_SHOW_PRINT_STATUS Show Print Status Dialog Wenn MS_PLTDLG_SHOW_PRINT_STATUS auf 1 eingestellt ist, zeigt der Druckdialog während eines Druckauftrags ein modusloses Dialogfeld für Status/Fortschritt/Abbrechen an. Dies ist das Standardverhalten. Wenn diese Variable auf '0' eingestellt ist, wird keine Druckstatus-Dialog angezeigt.
    MS_PLTDLG_THUMBNAIL_PREVIEW_TIMEOUT Thumbnail Preview Timeout Falls MS_PLTDLG_THUMBNAIL_PREVIEW_TIMEOUT auf einen Wert größer als Null eingestellt ist, ist dies die maximale Anzahl der Sekunden, die mit der Aktualisierung der Druckdialog-Miniaturbildvorschau verbracht werden dürfen. Der Standard beträgt 10 Sekunden.
    MS_PLTDLG_SHOW_ACCURATE_PREVIEW_ROTATION Preview Accurate Rotation Wenn MS_PLTDLG_SHOW_ACCURATE_PREVIEW_ROTATION auf '0' eingestellt ist, wird der  Plot in der Vorschau immer so angezeigt, als hätte er keine Drehung. Die Darstellung der Papierausrichtung  kann gewechselt werden, um dies zu erreichen. Diese Einstellung ist für Bentley-Druckertreiber  nur relevant, wenn die Plotdrehung 90 oder 270 Grad beträgt.
    MS_PLTDLG_SET_UNITS_FROM_SHEET Set Units From Sheet Wenn MS_PLTDLG_SET_UNITS_FROM_SHEET auf 0 gesetzt ist, werden die Druckeinheiten nicht automatisch durch den Druckdialog auf die in der Blattdefinition festgelegten Druckeinheiten gesetzt, wenn der aktuelle Druckmodus "Blatt" ist.
    MS_PLTDLG_KEEPVIEWFLAGSONFENCECHANGE Keep View Flags on New Fence Wenn ein neuer Zaun platziert wird, erhält der Druckdialog neue Informationen aus der Ansicht,  in der der Zaun platziert wurde, und setzt die Druckattribute zurück, falls die neue Zaunansicht  sich von der aktuellen Druckansicht unterscheidet. Wenn jedoch MS_PLTDLG_KEEPVIEWFLAGSONFENCECHANGE  eingestellt wird, behält der Druckdialog immer die aktuellen Druckattribute bei.
    MS_PLOTDLG_DEF_PENTABLE Default Pen Table Definiert Standard-Plotkonventionen, die geladen werden, wenn Sie den Druckdialog öffnen.
    MS_PLTDLG_SETUPSYSPRT_ENABLE_PRINT Enable Setup Sysprinter Print Controls the print behavior of the Configure Windows Printer icon.
    MS_PLTDLG_ENABLE_SAVE_CONFIG Enable Save Configuration Wenn MS_PLTDLG_ENABLE_SAVE_CONFIG auf 0 gesetzt ist, sind die  Menüelemente zum Speichern der Konfiguration deaktiviert.
    MS_PLTDLG_DISABLE_PREFERENCES_DIALOG Disable Plot Dialog Preferences Wenn MS_PLTDLG_DISABLE_PREFERENCES_DIALOG auf 1 eingestellt ist, wird das Element für Dialogvoreinstellungen im Menü 'Einstellungen' nicht angezeigt.
    MS_PLT_SCALE_METHOD Scale Method Die Variable MS_PLT_SCALE_METHOD bestimmt, wie die Druckskalierung im  Druckdialog dargestellt wird. Diese Variable überschreibt die entsprechende  Benutzervoreinstellung. Folgende Werte werden anerkann:
    '1': Die Skalierung erfolgt im Format Papier-zu-Zeichnung (Standard).
    '2': Die Skalierung erfolgt im Format Zeichnung-zu-Papier.
    Wenn diese Variable nicht definiert ist, steuert die Benutzervoreinstellung  die Skalierungsmethode. Diese Variable steuert zudem die Darstellung von MS_PLTSCALE_SHORT.
    MS_PENTABLE_IMPORTEMPTYSECTIONS Import Empty Pen Table Section Standardmäßig werden beim Import von AutoCAD-Plotkonventionen Abschnitte ignoriert, die keine Auswirkungen haben (Einstellungen entsprechen den Standardwerten). Durch Einstellen dieser Variable auf 1 wird die Erstellung leerer Abschnitte bewirkt.
    MS_PENTABLE_DISABLECOLOR Pen Table Disable Color Ein deaktivierter Abschnitt in den Plotkonventionen wird standardmäßig in Mittelgrau dargestellt. Sie können die Deaktivierungsfarbe ändern, indem Sie diese Konfigurationsvariable auf eine der folgenden Zahlen einstellen:  Blau=1
    MS_PENTABLE_SLOTNUM_MATCH_APPLIES_TO_CHILD Pen Table Slot Number Match Standardmäßig gilt der Vergleich der Referenzpositionsnummer in einer Plotkonvertion sowohl für die übergeordnete Referenz als auch deren untergeordnete Referenzen.  Wenn MS_PENTABLE_SLOTNUM_MATCH_APPLIES_TO_CHILD auf 0 gesetzt wird, gilt der Vergleich der Positionsnummer nur für die übergeordnete Referenz.
    MS_PENTABLE_SEARCH_LEVEL_LIBRARIES Pen Table Search Level Libs Wenn MS_PENTABLE_SEARCH_LEVEL_LIBRARIES auf '0' eingestellt ist, werden Ebenenbibliotheken bei der  Suche nach in den Plotkonventionen definierten Ebenennamen nicht einbezogen. Standardmäßig werden Ebenenbibliotheken einbezogen,  was zu Verzögerungen beim Laden der Plotkonvention führen kann.
    MS_PENTABLE_IMPORTCTB_NOPENMAP Pen Table Import Pen Maps Standardmäßig erstellen die Plotkonventionen beim Import von CBT-Dateien Plotzuordnungen für den Druckertreiber. Dies ermöglicht die korrekte Farbe-zu-Breite-Resymbolisierung von mehrfarbigen Elementen. Das alte Element-Ausgabe-Aktion-basierte Verhalten kann wiederhergestellt werden, indem die Konfigurationsvariable MS_PENTABLE_IMPORTCTB_NOPENMAP eingestellt wird.
    MS_PLTFILE_EDITOR Printer Configuration Editor Vollständig qualifizierter Name eines Texteditors, der verwendet werden soll, wenn das Menüelement "Datei/Druckertreiberkonfiguration bearbeiten" des Druckdialogs aktiviert ist. Stellen Sie beispielsweise den Wert auf "notepad.exe" (ohne die Anführungszeichen) ein, um den Windows-Texteditor zu verwenden.  Wenn diese Variable nicht definiert ist, wählt der Druckdialog automatisch den richtigen Editor basierend auf dem Format der Druckertreiberkonfigurationsdatei aus. Ältere .plt-Dateien werden mit Notepad bearbeitet, während .pltcfg-Dateien mit dem integrierten Druckertreiberkonfigurations-Editor von MicroStation bearbeitet werden. Für diese Variable gibt es zwei reservierte Werte:
    'HIDE_MENU_ITEM': Entfernt die Menübefehle "Druckertreiber bearbeiten" und "Druckertreiber neu laden" aus dem Datei-Menü des Druckdialogs.
    "MicroStation": Immer den integrierten Druckertreiberkonfigurations-Editor von MicroStation verwenden.
    MS_PLT_INVERT_WHITE_COLORS Invert White-to-Black Colors Mit der Variable MS_PLT_INVERT_WHITE_COLORS können Sie ggf. die Farben überschreiben, die  automatisch von Weiß in Schwarz umgekehrt werden. Wenn diese Variable nicht definiert ist, sind die Standardnummern  für umgekehrte Farben 0 und/oder 7, abhängig vom Zeichnungsdateiformat und der Farbtabelle. Die Syntax  für diesen Wert ist dieselbe wie eine Ebenennummernliste, mit dem Bereich 0-254.
    MS_PLT_ABBREVIATE_BORDER_FILENAME Abbreviate Border Filename Standardmäßig werden im Plotrandtext enthaltene Dateinamen abgekürzt, sodass nur der Dateiname und die Dateierweiterung angezeigt werden. Wenn diese Variable auf '0' eingestellt ist, wird der vollständige Dateipfad angezeigt.
    MS_PLT_AUTOAREA_RESULT_LIMIT Maximum print definitions Diese Variable definiert die maximale Anzahl der Druckdefinitionen, die  bei der Suche nach mehreren Polygonflächen oder Zellen erstellt werden sollen. Der Standardgrenzwert lautet 500.
    MS_PLT_UPDATE_FIELDS Update Fields when Printing Controls when fields are updated prior to printing or previewing. If set to 0 or undefined, fields are not updated prior to either printing or previewing. If set to 1, fields are updated prior to printing. If set to 2, fields are updated prior to both printing and previewing.
    MS_PLT_ENGINE_CMDLINE_ARGS Engine Command-Line Arguments Spezifiziert benutzerdefinierte Befehlszeilenargumente, die vom Druck-Organizer verwendet werden, um seinen Hintergrundarbeitsprozess aufzurufen. Wenn diese Variable nicht definiert ist, MS_CONFIG jedoch schon, wird der Hintergrundprozess mit dem Befehlszeilenargument -wc"$(MS_CONFIG)" (MS_PLT_ENGINE_CMDLINE_ARGS) aufgerufen.
    MS_PLT_ENABLE_VARIABLE_DEFINITION_MODE Use Variablenname Print Definitions Wenn MS_PLT_ENABLE_VARIABLE_DEFINITION_MODE auf 0 eingestellt ist, erstellt der Druck-Organizer festgelegte Druckdefinitionen. Bei Auswahl von 1 erstellt der Druck-Organizer variable Druckdefinitionen.
    MS_PRINTERLIST_SYSPRINTERS Printer List System Printer Ist dieser Wert auf '0' gesetzt, werden Windows-Druckernamen nicht in die Druckerliste des Druckdialogs aufgenommen.
    MS_PRINTERLIST_VISIBILITY Printer List Visibility Steuert das Verhalten der Auswahlliste für die Druckertreiberkonfigurationsdatei. Standardmäßig sind die meisten PLTCFG-Dateien und alle PLT-Dateien im Suchpfad MS_PLTCFG_PATH aufgeführt. Nur PLTCFG-Dateien mit der Eigenschaft 'Visible=0' sind nicht enthalten. Falls definiert, werden PLTCFG-Dateien mithilfe der Eigenschaft 'DisplayLabel' identifiziert. Ansonsten wird der Dateiname verwendet. Alte PLT-Dateien werden immer anhand des Dateinamens identifiziert.
    Mit dieser Variable kann der Sichtbarkeitstest für PLTCFG-Dateien gesteuert werden. Der Wert '2-4,6' nimmt nur PLTCFG-Dateien in die Liste auf, deren Wert für die Eigenschaft 'Visible' 2,3,4 und 6 sind. Für alle PLT-Dateien sowie für PLTCFG-Dateien, für die die Eigenschaft 'Visible' nicht explizit definiert ist, wird für die Eigenschaft 'Visible' ein Wert von 1 angenommen.
    Es gibt zwei reservierte Werte:
    '0': Nicht nach Druckertreiberkonfigurationsdateien suchen. Die Auswahl ist nur über ein Datei-Auswahlfeld möglich. Alle Dateien werden ausschließlich mithilfe des Dateinamens identifiziert.
    '-1': Nach Druckertreiberkonfigurationsdateien suchen, aber deren Eigenschaften 'DisplayLabel' oder 'Visible' nicht lesen. Alle Dateien werden durch ihren Dateinamen identifiziert. Diese Einstellung kann nützlich sein, wenn die zum Erstellen der Liste erforderliche Zeit relevant ist.
    MS_PRINTORGANIZER_OPEN_DGN_READWRITE Open Designs Read-Write Wenn MS_PRINTORGANIZER_OPEN_DGN_READWRITE auf 1 eingestellt ist, öffnet der Druck-Organizer  im Hintergrund Zeichnungsdateien im Modus Lesen/Schreiben.  Bestimmte Druck-Workflows hängen davon ab, ob die Zeichnungsdatei beschreibbar ist.
    MS_PROPFILTER_PATH Eigenschaftsfilter-Suchpfad Suchpfad für Eigenschaftsveröffentlichungs-Filterdateien.
    MS_PLTDLG_SHOW_ACCURATE_PREVIEW_ROTATION Wenn MS_PLTDLG_SHOW_ACCURATE_PREVIEW_ROTATION auf '0' eingestellt ist, wird der  Plot in der Vorschau immer so angezeigt, als hätte er keine Drehung. Die Darstellung der Papierausrichtung  kann gewechselt werden, um dies zu erreichen. Diese Einstellung ist für Bentley-Druckertreiber  nur relevant, wenn die Plotdrehung 90 oder 270 Grad beträgt.
    MS_PLT_ACCTVAR_ABBREV_LEN Steuert die Länge der Dateipfadabkürzung für Druckabrechnungsvariablen. Standardwert ist 34.
    MS_PLT_DEFAULT_PRINTDEF_NAME_EXPRESSION Bestimmt die Länge der Dateipfadabkürzung für Druckabrechnungsvariablen. Bestimmt den Namen einer 'Druckdefinition' anhand eines Ausdrucks, der verwendet werden soll, wenn von Druck-Organizer ein neuer Drucksatz erstellt wird.
    MS_PLT_DEFAULT_OUTPUT_FILENAME_EXPRESSION Bestimmt den Namen einer 'Druckausgabedatei' anhand eines Ausdrucks, der verwendet werden soll, wenn von Print Organizer ein neuer Drucksatz erstellt wird.




    top

    Schutz

    MicroStation includes configuration Variablennamesto help set up all aspects of the file protection.

    The following table lists the configuration Variablennames that affect Protection. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_PROTECTION_ENABLE Enable file protection
    • Set to 0 to disable file protection (default)
    • Set to 1 to enable password or certificate protection
    • Set to 2 to enable password protection
    • Set to 3 to enable certificate protection
    MS_PROTECTION_V8_COMPATIBILITY Limit encryption strength
    • Set to 0 to use stronger encryption, producing protected files that previous versions cannot open (default)
    • Set to 1 to enable previous versions to open protected files and create licenses
    MS_PROTECTION_LICENSE_ENABLE Control license creation
    • Set to 0 to disable license creation
    • Set to 1 to enable password licenses
    • Set to 2 to enable certificate licenses
    • Set to 4 to enable Everyone licenses
    • Set to 7 to enable all types of licenses (default)

    Add individual values together to enable two or more license types.

    MS_PROTECTION_PASSWORD_MIXED Password letters and numbers A password containing a mixture of letters and numbers.
    MS_PROTECTION_PASSWORD_MINIMUM Minimum length of password Sets the minimum length of a file protection password. The default is 5.
    MS_PROTECTION_NOENCRYPT_THUMBNAIL Do not encrypt file thumbnail The thumbnail is an image of the last used view of the design file. The image is displayed by Windows File Explorer and File Open dialog.
    MS_PROTECTION_NOENCRYPT_PROPERTIES Do not encrypt file properties Set to 1, tells the Protect command to leave file properties unencrypted or set to 0 to allow Protect encrypt file properties.




    top

    Raster

    MicroStation includes configuration Variablennamesto help set up all aspects of the rasters.

    The following table lists the configuration Variablennames that affect Raster files. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_RASTER_IMG_STRETCH Set contrast stretch filtering Specifies a contrast stretch filtering to be applied to any Erdas IMG file whose detected pixel type is grayscale 8 bits, RBG 24 bits or RGBA 32 bits. Possible values are as follows :
    1 or 0
    Where
    0 : No contrast stretch is applied.
    1 : A contrast stretch filtering is applied before displaying the image.
    MS_RASTER_IMG_CHANNELS Set band to channel mapping for IMG file format Sets the band number to use for Red, Green, Blue and Alpha channels when a file whose format is IMG is attached. The ‘0’ value can be set for the Alpha channel if none is required. When this Variablenname is defined, all attached Erdas IMG rasters will use the same band order. The default value is: MS_RASTER_IMG_CHANNELS 1 2 3 4.
    MS_RASTER_DISABLE_IPPCONNECTION Disable default server port If undefined, the default socket server port 1924 is used.
    If defined, the socket port 1924 is ignored.
    MS_RASTER_VIEWSAVEASDWG Define view for DWG file

    When exporting to DWG, controls whether the raster is displayed.
    If set to 0 or undefined, the raster is displayed in View 1.
    If set to 1 to 8, the raster is displayed in the specified view.
    If set to 9, the raster is displayed in at least one view.
    If set to 10, the raster is displayed in all views.

    MS_RASTER_COMMONGEOREFFILEFORMATS Set default 'Common Geo Ref Raster Formats' file filter for the Open dialog Sets the extension(s) of the file formats to use as the default "Common Geo Ref Raster Formats" file filter for the Open dialogs. Use a semicolon to separate file extensions. Do not add a semicolon to the end of the list. For example: *.hmr;*.iTiff;*.tiff
    MS_RASTER_COMMONFILEFORMATS Set default 'Common Raster Formats' file filter for the Open dialog Sets the extension(s) of the file formats to use as the default “Common Raster Formats” file filter for the Open dialogs. Use a semicolon to separate file extensions. Do not add a semicolon to the end of the list. For example: *.hmr;*.iTiff;*.tiff
    MS_RASTER_TIFFINVERT Invert monochrome tiff If defined and set to a non-zero value, inverts the foreground/background color allocation of monochrome tiff files when the raster is attached.
    MS_RASTER_SAVEAUTO Set Automatic Save mode Enables Raster Manager Automatic Save mode when closing a DGN or detaching a raster.
    If undefined or set to 0, Save Auto is off.
    If set to 1, Save Auto is enabled and the user will not be prompted to update the raster for changes made to the location info of the file.
    MS_RASTER_NOSHARING Creating .sharing.tmp files Manages the automatic creation of .sharing.tmp files for concurrent access of the same raster file by various instances of MicroStation. If undefined or set to 0, .sharing.tmp files are generated.
    If set to 1, .sharing.tmp file generation is off.
    MS_RASTER_NO_DETACH_CONFIRM Display alert dialog upon raster If set to 0, displays an alert dialog asking to confirm the raster detachment. If undefined or set to 1, does not display the alert dialog.
    MS_RASTER_EPSGTABLE_PATH Set path to EPSG table Enables geotiff positioning using the location parameters found in ASCII files provided on request.
    The required ASCII files are:
    • CoordSysData.txt
    • ProjectionData.txt
    • UnitsData.txt

    If undefined or set to 0, hard-coded tables are used.
    If set to 1, ASCII files are used.

    MS_RASTER_DEFAULTSISTER Set default sister file If set to 0 or 1, HGR is the default sister file.
    If set to 2, WorldFile is the default sister file.
    MS_RASTER_DEFAULTSCALE Set default scale If undefined, or if defined and set to 1, a non-georeferenced raster that is attached without the use of the Place Interactively check box is assigned a scale of 1. The pixel size is derived from the scale and DPI.
    If defined and set to a value greater than 1, a non-georeferenced raster that is attached without the use of the Place Interactively check box is assigned a scale equal to the value of MS_RASTER_DEFAULTSCALE. The pixel size is derived from the scale and DPI.
    MS_RASTER_1BIT_WORKMODE Harmonize monochrome raster display If defined and set to 1, harmonizes monochrome raster display so they are handled like raster reference attachments.
    If undefined or set to 0, has no effect.
    MS_RASTER_DEFAULT_LEVEL Set default display level Defines the level for raster elements when upgrading to MicroStation V8i. The value is the LevelName.
    MS_RASTER_TRANSPARENCY Set transparency If defined and set to 1, Raster Manager sets the background transparency value, as specified in the Raster Manager Transparency dialog. Possible values are 0 to 255, where 255 is 100% transparency.
    If undefined or set to 0, has no effect.




    top

    Referenzen

    MicroStation includes configuration Variablennames to help set up all aspects of the references.

    The following table lists the configuration Variablennames that affect reference files. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_DISALLOWFULLREFPATH Disallow Full Ref Path If set, the product does not save the full path to references. By default, the product stores both an abbreviated (portable) path and the full path to references.
    MS_NEST_COLORADJUSTMENT Nested Reference Color Adjustment If set to any value, the nested reference color adjustments at each level are multiplied by this value. If not set, the color adjustment for the top level reference controls the color adjustment for all nested references.
    MS_REF_DEFAULTATTACHDIRECTORY Default Attachment Directory If set, the Attach Reference dialog defaults to this directory, rather than the directory of the last attached reference.
    MS_REF_DEFAULTSETTINGS Default Attachment Settings Controls the default settings for reference attachments. This Variablenname is set to a comma-separated list of key=value pairs — for example: snap=1,locate=0,trueScale=1,scaleLineStyles=0.
    Recognized keys and values include: display=0|1, snap=0|1, locate=0|1, treatAsElement=0|1, attachMethod=coincident|world|geoReprojected|geoAECTransform, useLights=0|1, saveRelativePath=0|1, scaleLineStyles=0|1, ignoreWhenNesting=0|1, displayRasterRefs=0|1, displayBoundary=0|1, newLevelDisplay=fromconfig|always|never, nestMode=live|copy|none, nestDepth=<value>,nestOverrides=allow|always|never, useAnnotationScale=0|1, synchWithSavedView=none|volume|allsettings, levelControlDisplay=0|1, plotAs3D=0|1.
    Also, to store the complete path to V7 files for newly attached references, set the Variablenname to completepathv7=1.
    MS_REF_DONTHILITEFORMANIP Hiliting References for Manipulation

    By default, the product highlights all elements in a reference file when the reference is manipulated. If this Variablenname is set to any value, this highlighting is disabled. Disabling speeds up the reference manipulations but makes it more difficult to see which references are being manipulated.

    MS_REF_ENABLE_LEGACY_VISEDGE Enable Visible Edges "Legacy" Option If set to 1, the Legacy option for the reference Visible Edges drop-down is displayed. The Cached option replaces the "Legacy" (True Hidden Line) option and provides superior performance and accuracy.
    MS_REF_MASTERFILELAST_DESIGN Design Model Update Sequence Controls the default update sequence of references and master model in the design model. If 0, the default, the master design model is visible on top of the references.
    MS_REF_MASTERFILELAST_DRAWING Drawing Model Update Sequence Controls the default update sequence of references and master model in the drawing model. If 1, the default, the references are visible on top of the master drawing model.
    MS_REF_MASTERFILELAST_SHEET Sheet Model Update Sequence Controls the default update sequence of references and master model in the sheet model. If 1, the default, the references are visible on top of the master sheet model.
    MS_REF_NEWLEVELDISPLAY New Level Display If set, the product displays newly created levels in references. By default, when new levels are created in a model that is referenced by another model, the new levels are not displayed when the referencing model is opened. Newly created models are considered until "Save settings" is performed. This functionality only works when both the master file and referenced files are in the V8 file format.
    MS_REF_NO_CVE_LOAD Disable loading of CVE References If set to 1, any cached reference will not be loaded. This effectively overrides cached reference to use the "Cache Synch: Never (Disconnected)" option.

    Setting MS_REF_NO_CVE_LOAD can reduce the time to open large data sets. However, element properties are not available and certain annotation tools may not be available for the unloaded/disconnected cached references.

    The following configuration Variablennames affect reference files but they do not appear in the Configuration Variablennames dialog.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_REF_NOMISSINGREPORT (not applicable) If set, the Message Center window does not display a message if references are not located.
    MS_REF_NOSURVEYFOOTCHECK (not applicable) If set, hides the alert window that opens when you attach a reference with working units set to US Survey Feet to a model whose working units are set to Feet (International Feet), or vice-versa.




    top

    Rendern / Bilder

    The following table lists the configuration Variablennames that affect rendering and images. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_LOCAL_MATERIALS Local Material Setting Serves the same function as the Copy Materials Locally On Use toggle in the Settings menu of the Material Editor dialog.
    If set to 1, materials are made local on use and the DGN file defaults to a local table if one does not exist already (as it would if Copy Materials On Use was enabled).
    If set to zero, or undefined, then localization of used materials is controlled by the Copy Materials Locally On Use toggle.
    Local material support is new as of the V8 XM Edition and is not supported by earlier versions.
    MS_MTBL Material Tables Search path(s) for material tables.
    MS_MATERIAL Material Palettes Suchpfad(e) für Materialpaletten.
    MS_PATTERN Pattern Maps Suchpfad(e) für Texturen.
    MS_BUMP Bump Maps Suchpfad(e) für Schraffuren.
    MS_IMAGE Images Suchpfad(e) für Darstellungen.
    MS_IMAGEOUT Image Output Verzeichnis, in dem bereits erstellte Darstellungen gespeichert werden.
    Directory in which image files created with Drawing > Utilities > Image > Save Image and Drawing > Utilities > Image > Capture are stored.
    MS_SHADOWMAP Shadow Maps Verzeichnis, aus dem Shadow Maps gelesen und in das sie geschrieben werden.
    MS_LIGHTING IES Lighting Files Verzeichnis, aus dem IES-Beleuchtungsdaten gelesen werden.
    MS_LIGHTLIST Pre-defined Light Sources Liste der Zeichnungsdateien, die Lichtquellen enthalten, die bei der Platzierung von Lichtern als Vorlage dienen sollen. Alle in diesen Dateien gefundenen Lichtquellen können aus der Drop-down-Liste neben dem Namen der Lichtquelle in der Funktion 'Lichtquelle definieren' ausgewählt werden.
    MS_RENDERLOG Rendering statistics log File in which rendering statistics are logged.
    MS_SHARED_DR_DIR Distributed Rendering Directory Working directory for shared rendering files.
    MS_IMAGE_EDITOR Image Editor Standardprogramm zur Bearbeitung einer Bilddatei. Dieses Programm wird durch Doppelklicken im im Vorschaubereich des Dialogs 'Map-Editor' aktiviert.
    MS_MATERIAL_PREVIEW_BACKGROUND Material Preview Background Das Bild, das bei der Materialvorschau im Material-Editor als Hintergrund dienen soll.
    MS_FILTEREDCODECS Filtered DirectShow Codecs Codecs, die in der Liste der verfügbaren AVI-Codecs nicht erscheinen sollten, wenn eine Animation aus dem Animator exportiert wird.
    MS_RENDERV7MATERIALS V7 Material Compatibility Wenn diese Variable auf 1 gesetzt ist, werden Materialien wie in V7 gerendert. Davon am meisten betroffen sind die Texturen zugewiesene Lichtdurchlässigkeit, Transparenz, Spiegelung und Diffusität.
    MS_DISABLE_RPCBROWSER Disable RPC Thumbnail Browser Wenn diese Option auf 1 gesetzt wird, wird der RPC-Miniaturbild-Browser deaktiviert.
    MS_RPCDIR RPC Search Path Verzeichnis für die Suche nach RPC-Dateien.




    top

    Berichte

    VariablennameBeschreibungDetailierte Beschreibung
    MS_REPORT_OUTPUT  Report Output  Ausgabeverzeichnis für den Export von Berichtsergebnissen




    top

    Sicherheit

    The following table lists the configuration Variablennames that affect Security. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_SECURITY_LEVEL Security level Security level for loading and running applications.
    MS_SECURITY_SPC Software Publishing Certs List of a wildcard expressions indicating where MicroStation can find the files that contain public copies of software publishing certificates that were used to digitally sign the applications that can be loaded in MEDIUM security level. These files normally have the ".cer" extension. They contain information about certificates and public keys. They do not contain private keys. For example, "c:\mycerts\*.cer". The default is "$(_USTN_SITE)SPC\*.cer". (MS_SECURITY_SPC).




    top

    Seed-Dateien

    The following table lists the configuration Variablennames that affect Seed Files. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_BUTTONMENUSEED Button Assignment Seed File Datei, die vordefinierte Tastenzuordnungen enthält. Diese Datei legt die Tastenzuordnungen fest, wenn die in MS_BUTTONMENU angegebene Datei nicht gefunden wird.
    MS_CELL_SEEDFILE Cell Library Seed File Seed-Datei, die beim Erstellen oder Aktualisieren von Zellbibliotheken verwendet wird.
    MS_DESIGNMODELSEED Design Model Seed File Name der Datei mit dem Seed-Modell für neue Zeichnungsmodelle.
    MS_DESIGNMODELSEEDNAME Design Model Seed Name des Seed-Modells für neue Zeichnungsmodelle.
    MS_DESIGNSEED Default Design File Seed Standard-Seed-Datei zum Erstellen von Zeichnungsdateien.
    MS_DOCKINGPREFSEED Dialog Docking Preference Seed Pfad einer XML-Datei für Standard-Dialogdockingvoreinstellungen.
    MS_DRAWINGMODELSEED Drawing Model Seed File Name der Datei mit dem Seed-Modell für neue Planmodelle.
    MS_DRAWINGMODELSEEDNAME Drawing Model Seed Name des Seed-Modells für neue Planmodelle.
    MS_DWGSEED DWG Seed File Name der Seed-Datei, die zur Erstellung der DWG-Datei verwendet wird.
    MS_DWGSEED_OVERRIDE DWG Seed File Override Steuert, wie eine DGN-Seed-Datei zum Speichern von DWG-Dateien verwendet werden kann: 0 = Die Seed-Datei kann im Dialog 'DWG-Speicheroptionen' geändert werden.
    MS_DWGSHEETMODELSEED DWG Sheet Model Seed File Name der Datei mit dem Seed-Modell für neue Blattmodelle in DWG-Dateien.
    MS_DWGSHEETMODELSEEDNAME DWG Sheet Model Seed Name des Seed-Modells für neue Blattmodelle in DWG-Dateien.
    MS_FKEYMNUSEED Function Key Assignments Seed File MS_FKEYMNUSEED Datei, die vordefinierte Funktionstastenzuordnungen enthält. Diese Datei legt die Funktionstastenzuordnungen fest, wenn die in
    MS_FKEYMNU angegebene Datei nicht gefunden wird.
    MS_GROUPPANELPREFSEED Group Panel Preference Seed Pfad einer XML-Datei mit den Standardvoreinstellungen für Gruppenbereiche.
    MS_INPUT_CONFIGXMLSEED Touch Gesture Assignments Seed File Datei, die vordefinierte Touch-Gesten-Zuordnungen enthält. Diese Datei legt die Touch-Gesten-Zuordnungen fest, wenn die in MS_INPUT_CONFIGXML angegebene Datei nicht gefunden wird.
    MS_PERSONALDGNLIBSEED Personal DGNLib Seed Standard-Seed-Datei für die Erstellung der persönlichen dgnlib-Datei.
    MS_SEED_LINKSET_FILE_NAME Link Set Seed File Benutzerdefinierter Name der Verknüpfungsgruppe (die in der Datei gespeichert ist, die mit der Variable MS_SEED_LINKSET_FILE_NAME definiert ist), der beim Erstellen der neuen Verknüpfungsgruppe kopiert wird.
    MS_SEED_LINKSET_NAME Link Set Name Benutzerdefinierter Name der Verknüpfungsgruppe (die in der Datei gespeichert ist, die mit der Variable MS_SEED_LINKSET_FILE_NAME definiert ist), der beim Erstellen der neuen Verknüpfungsgruppe kopiert wird.
    MS_SEEDFILES Seed File Location Suchpfad(e) für alle Seed-Dateien.
    MS_SHEETMODELSEED Sheet Model Seed File Name der Datei mit dem Seed-Modell für neue Blattmodelle.
    MS_SHEETMODELSEEDNAME Sheet Model Seed Name des Seed-Modells für neue Blattmodelle.
    MS_SHEETSEED Drawing Sheet Seed File Seed-Datei, die zum Erstellen von Zeichnungsblättern benutzt wird.
    MS_TASKDIALOGPREFSEED Task Navigation Dialog Preference Seeed Pfad einer XML-Datei mit den Standardvoreinstellungen für den Dialog Task-Navigation.
    MS_TRANSEED Default Translation Seed Standard-Seed-Datei, die für DWG-, CGM- und IGES-Übersetzungen verwendet wird.
    MS_TRANSEED_OVERRIDE Translation Seed Override Steuert, wie eine DGN-Seed-Datei zum Öffnen von DWG-Dateien verwendet werden kann:
    0 = Die Seed-Datei kann im Dialog 'DWG-Öffnungsoptionen' geändert werden;
    1 = MS_TRANSEED übergeht die Benutzereinstellungen immer;
    2 = MS_TRANSEED übergeht die Benutzereinstellungen nur beim Start von MicroStation.

    When the Variablenname is not set or set to 0, the first time that the dialog opens, the default DGN Seed File is set by the MS_TRANSEED configuration Variablenname. The user can choose a different seed file.
    When the Variablenname is set to 1, the user can only use the DGN seed file identified by MS_TRANSEED. The user cannot choose a different seed file.
    When the Variablenname is set to 2, the default DGN seed fie is set by MS_TRANSEED at the beginning of each session. The user can choose a different seed file during the session.
    MS_USERPREFSEED User Preference Seed Name der Seed-Datei, die zur Erstellung der Ressourcendatei für Benutzervoreinstellungen verwendet wird.
    MS_VIEWGROUPSEED View Group Seed File Name der Datei mit der Seed-Ansichtsgruppe für Modelle ohne Ansichtsgruppe.
    MS_VIEWGROUPSEEDNAME View Group Seed Name der Seed-Ansichtsgruppe für Modelle ohne Ansichtsgruppe.




    top

    Rechtschreibung

    The following table lists the configuration Variablennames that affect spelling. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    Configuration VariablennameBeschreibungDetailierte Beschreibung
    MS_SPELLINGUSERDICTIONARY Spelling User Dictionary Definiert das Benutzerwörterbuch.
    MS_SPELLINGDICTIONARYPATH Spelling Dictionaries Definiert das Verzeichnis, in dem nach den wichtigsten Wörterbüchern gesucht werden soll.
    MS_SPELLING_CUSTOM_AFFIX_FILE (not applicable) Specifies the directory to search for the .aff file of user dictionary.
    MS_SPELLING_CUSTOM_WORD_FILE (not applicable) Specifies the directory to search for the .dic file of user dictionary.




    top

    Standardsprüfung

    The following table lists the configuration Variablennames that affect the Standards Checker. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_STANDARDSCHECKER_SETTINGSFILE Required Standards Checker Settings File Sets the *.dgnlib file used for standards checking. If this Variablenname is set, the specified file is always used for standards checking.
    MS_STANDARDSCHECKER_SETTINGSNAME Required Standards Checker Name Sets the name of the settings to use (within the file specified by MS_STANDARDSCHECKER_SETTINGSFILE). If this Variablenname is set, you cannot select different named settings.
    MS_STANDARDSCHECKER_OUT Standards Checker Report Directory Default directory for standards checker reports.
    MS_STANDARDSCHECKER_STYLESHEET Standards Checker Style Sheet If this Variablenname is set, it specifies the XML style sheet that is used to view the Standards Checker XML report. This Variablenname can be either a file or a URI (Universal Resource Identifier) that can be used by the browser to locate the style sheet. If this Variablenname is not set, the XML style sheet in $(MS_DATA)standardschecker.xsl is used.
    MS_STANDARDSCHECKER_APPS Standards Checker Applications The list of MDL applications that are loaded when the Standards Checker utility is started.




    top

    Symbolik

    VariablennameBeschreibungDetailierte Beschreibung
    MS_FONTCONFIGFILE Font Configuration File Path Pfad einer Schriftartenkonfigurationsdatei, die je nach Ländereinstellung Optionen für Zeichnungstextelemente sowie Schriftarten-Metadaten für RSC- und SHX-Schriften enthält. Default path is “$(MS_SYSFONTDIR)/MstnFontConfig.xml”.
    MS_FONTPATH Font Directories Pfad oder Liste der Pfade, der/die RSC-, SHX- oder TrueType-Schriftartdateien enthält/enthalten.
    MS_SYMBRSRC  Symbology Resources Eine Liste von Symbolik-Ressourcendateien. Dateien werden in der Reihenfolge geöffnet, in der sie in der Liste erscheinen. Die letzte Datei in der Liste hat die höchste Priorität. Wenn die Variable nicht definiert ist, wird der aktuelle Ressourcenpfad nach der Datei "mssymb.rsc" durchsucht.




    top

    Systemumgebung

    VariablennameBeschreibungDetailierte Beschreibung
    MS_CONFIG Main Configuration File Die  Hauptkonfigurationsdatei, mit der alle Konfigurationsvariablen eingerichtet werden.
    RSC_COMP  Resource Compiler Command Line Spezifiziert Text, der vom Ressourcen-Kompilierer am Anfang der Befehlzeile eingefügt wird. Hier wird gewöhnlich angezeigt, wo nach Include-Dateien gesucht werden soll.
    MDL_COMP MDL Compiler Command Line Spezifiziert Text, der vom MDL-Kompilierer und rsctype am Anfang der Befehlzeile eingefügt wird. Hier wird gewöhnlich angezeigt, wo nach Include-Dateien gesucht werden soll.
    BMAKE_OPT Extended Malloc Befehlzeilenoptionen für BMAKE. Hier wird gewöhnlich angezeigt, wo nach bmake-Include-Dateien (.mki) gesucht werden soll.
    MS_DEBUGMDLHEAP  Table Input Auf den Basisnamen einer MDL-Applikation (oder "ALL") eingestellt.  Bei dieser Einstellung erweiterte Speicherzuweisung für das Debug-Programm benutzen. Sie muss als Systemumgebungsvariable eingerichtet sein.




    top

    Tabellen

    VariablennameBeschreibungDetailierte Beschreibung
    MS_TABLE_INPUT  Table Input Verzeichnis, das die Excel-Arbeitsmappen und CSV-Dateien enthält, die als Datenquellen für Tabellen verwendet werden




    top

    Sachdaten

    The following table lists the configuration Variablennames that affect tags. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_TAGOUTPUT Tag Output Ausgabeverzeichnis für allgemeine Sachdaten.
    MS_TAGREPORTS Tag Reports Ausgabeverzeichnis für Reports vom Sachdatenmanager.
    MS_TAGTEMPLATES Tag Templates Verzeichnis, in dem sich die Reportvorlagen des Sachdatenmanagers befinden.




    top

    Temp- und Backupdateien

    VariablennameBeschreibungDetailierte Beschreibung
    MS_DWG_BACKUP Directory for DWG backup files Verzeichnis für DWG-Backup-Dateien (.bak). Wenn dies nicht definiert wurde, werden die Backup-Dateien in dasselbe Verzeichnis gestellt wie die DWG-Datei.
    MS_NO_DWG_BACKUP Turn off DWG .bak files Wenn dieser Wert definiert wurde, werden .bak-Dateien bei der Bearbeitung einer DWG- oder DXF-Datei nicht bearbeitet.
    MS_BACKUP  Backup Files  Standardverzeichnis für Backup-Dateien.
    MS_TMP Temporary Files Das Verzeichnis für die temporären Zwischendateien von MicroStation.
    MS_SCR   Scratch Files Verzeichnis der Arbeitsdateien.




    top

    CGM-Übersetzung

    The following table lists the configuration Variablennames that affect CGM Translation. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_CGMIN CGM Input Directory Eingabeverzeichnis für CGM-Übersetzungen.
    MS_CGMOUT CGM Output Directory Ausgabeverzeichnis für CGM-Übersetzungen.
    MS_CGMLOG CGM Log Files Ausgabeverzeichnis für CGM-Übersetzungen.
    MS_CGMTABLES CGM Configuration Tables Verzeichnis, das die CGM-Übersetzungstabellen enthält.
    MS_CGMINSET CGMIN Settings File Einstellungsdatei für die CGMIN-Applikation.
    MS_CGMOUTSET CGMOUT Settings File Einstellungsdatei für die CGMOUT-Applikation.




    top

    IGES-Übersetzung

    The following table lists the configuration Variablennames that affect CGM Translation. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_IGESIN IGES Input Directory Eingabeverzeichnis für IGES-Übersetzungen.
    MS_IGESOUT IGES Output Directory Ausgabeverzeichnis für IGES-Übersetzungen.
    MS_IGESLOG  IGES Log Files Ausgabeverzeichnis für IGES-Protokolldateien.
    MS_IGESINSET IGES Configuration Tables Einstellungsdatei für die IGESIN-Applikation..
    MS_IGESOUTSET IGES Settings File Einstellungsdatei für die IGESOUT-Applikation..




    top

    Step-Übersetzung

    The following table lists the configuration Variablennames that affect Step Translation. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_STEPOUT Step Output Directory. Ausgabeverzeichnis für Step-Übersetzungen.
    MS_STEPLOG Step Log Files. Ausgabeverzeichnis für Step-Protokolldateien.
    MS_ROSEDB Rose database directory.

    Rose-Datenbankverzeichnis.




    top

    VBA

    The following table lists the configuration Variablennames that affect Visual Basic for Applications. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect.

    VariablennameBeschreibungDetailierte Beschreibung
    MS_VBASAVEONRUN Automatically save VBA projects If set to 1, automatically saves modified VBA projects every time it starts running a VBA program.
    MS_VBAAUTOLOADPROJECTS Names of standard projects Names of the projects that are opened when the VBA dialog is opened.
    MS_VBASEARCHDIRECTORIES Directories to search for VBA projects Directories that are searched when opening an existing VBA project.
    MS_VBANEWPROJECTDIRECTORY Directory for new projects Directory that is used when a new project is created.




    top

    Uncategorized Configuration Variablennames

    The following table lists the configuration Variablennames that are uncategorized. Each configuration Variablenname expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration Variablenname change to take effect, unless noted.

    VariablennameDetailierte Beschreibung
    MSDIR The root installation directory.
    MSLOCAL Specifies the base directory path for where the required writable portions (that is, local for a network installation) are installed.
    MS_80TRUETYPESCALE If set to 1, TrueType fonts using nonstandard TrueType definitions will display as they did prior to V8.
    MS_ALWAYSRELATIVEREFPATH If set (to any value), always turns on the Save Relative Path check box and disables it so that it cannot be turned off. It will save relative paths whenever possible.
    MS_ANNOTATIONSCALEPROPAGATION Controls the propagation of a model's annotation scale.
    If set to NEVER, the annotation scale will not be propagated , which is not recommended. If undefined or set to any other value, the annotation scale will be automatically propagated.
    We recommend that you use a single annotation scale for all annotations in a model. When you attach a model containing annotations to another model, the Use Active Annotation Scale setting allows you to automatically scale all reference annotations to the same scale as the master model. If your reference model has annotations of different scales, those annotations that do not match their model's annotation scale may face display, selecting, and printing problems. There may also be a performance slowdown.
    MS_ARCHIVE Search path for archive files.
    MS_ARCHIVECLASS Search path for archive class files.
    MS_AUTO_UPDATE_FIELDS Controls the rules for updating fields in the active model. If set to ALWAYS, the fields are always kept up to date. If set to NEVER, the fields are never updated. If not set or set to FOLLOWMODELFLAG, the model's Auto-Update Fields property determines if fields are updated for that model.
    MS_BASICEXT_LOAD List of MDL applications that implement extensions to the BASIC language (MS_BASIC_LOAD).
    MS_CMDTABLE_LOAD List of MDL applications that will have their key-in tables auto-loaded.
    MS_CMDWINDRSC Command Window resource file. Default is used if undefined.
    MS_CODESET MDL application for handling multi-byte character sets.
    MS_DATA Directory for data files created or used.
    MS_DBOLEDBDATEFORMAT See Setting Up the Database Interface
    MS_DEFCHARTRAN Default character translation table.
    MS_DEFAULTSHEETRGB Allows you to specify a different background color, which is used when you create the first sheet model. Expects an RGB triplet separated by commas.
    MS_DEFAULTDRAWINGRGB Allows you to specify a different background color, which is used when you create the first drawing model. Expects an RGB triplet separated by commas.
    MS_DESIGNFILTER Default file filter for the File Open, Open, and Save As dialogs. If MS_DESIGNFILTER is not defined, the default filter is "*.dgn".
    MS_DETAILINGSYMBOLSTYLE_REQUIREDSETTINGS Allows you to customize the validation rules of detailing symbol styles.
    MS_DGNAPPS List of all design file MDL applications.
    MS_DGNINDEXER_PORT If set, the application uses this port to connect to the remote DGN Indexing servers. The default value is 4000.
    MS_DGNOUT Directory containing DGN files created as a result of "on the fly" translation from other file formats.
    MS_DIMLEGACYPOINTORDER If set to 1, the dimensioning tools use the legacy data point sequence for placing linear and angular dimensions (StartPoint – ExtensionPoint – EndPoint).
    MS_DISABLEWINDOWGHOSTING If set to 1 or ON, disables the window ghosting mechanism in the Windows OS. Windows creates a ghost window for the application's windows when it determines that an application has been unresponsive for at least five seconds. Several features, such as Print/Plot and Image Save, may require a long span of continuous processing time, resulting in the activation of these ghost windows and the associated undesirable side effects in the user interface. Turning off the window ghosting for the process prevents these undesirable effects.
    MS_DISALLOWRELATIVEREFPATH When set to 1, you cannot save a relative path for a reference. The Save Relative Path check box is removed from the Attach Reference dialog.
    MS_DRAWINGDIR Specifies the default folder path that should open when you click the Browse Drawing File or Create New Drawing File icons in the Create Drawing dialog.
    MS_DWG_XREF_DEFAULTTREATASELEMENT_OFF When this Variablenname is not set, DWG’s xReference attachments are treated as elements, just as they are in AutoCAD. When it is set to 1, the attachments are not be treated as elements.
    MS_ELEVPROP_AS_Z Allows you to assign elevation attributes as Z values during SHP, MIF/MID, or TAB file Import/Open/Attachment. This is accomplished by setting the value to one or more property names that you used to indicate elevation in your SHP, MIF/MID, or TAB files. For example, if you have a SHP, MIF/MID, or TAB file that uses a property called "ELEVATION" to contain elevation data, you would set:
    MS_ELEVPROP_AS_Z=ELEVATION
    If you have an additional SHP, MIF/MID, or TAB file that uses a property called "HEIGHT" to contain elevation data , you can use a vertical "|" delimiter to specify two elevation attributes as follows:
    MS_ELEVPROP_AS_Z=ELEVATION|HEIGHT
    MS_GUIHAND Identifies auxiliary handlers.
    MS_HELPLOAD_APPLICATION Determines which application help is based on. Current options are HTMLHelp (default), or StaticWeb. StaticWeb refers to static HTML pages on a web site.
    MS_HELPLOAD_SERVER Specifies the root location of the help content. Defaults to $(USTN_DOCUMENTATIONROOT), but can be set to a file server or URL. This Variablenname does not determine if you are using uncompiled HTMLHelp content. If you set this Variablenname, the value of MS_HELPLOAD_SERVER should be the location containing the product directory.
    MS_HELPPATH Path to help resource files.
    MS_INITAPPS List of initial start-up MDL applications.
    MS_LEVEL_DO_NOT_SYNCHRONIZE_ATTACHMENT_LEVELS_TO_DGNLIB If set to 1, the reference attachment levels are not synchronized to the attached library.
    MS_MEASURE_AREA_UNIT2 If set to 1, the unit of measurement in the Area or Volume fields is displayed as unit2. For example, m2 for Square meters and m3 for Cubic meters. If not set, it is displayed as Sq.unit or Cu.unit. For example, Sq.m for Square meters and Cu.m for Cubic meters.
    MS_NO_POSITION_MAPPING_HINTS If set to 1, the keyboard navigational aids will not display when <Esc> is clicked.
    MS_NOTEAUTOUPDATE Controls the list of settings that will be propagated to existing notes when a dimension style is saved. To propagate all settings, set to All. To control individual settings, list attributes in a comma-separated list.
    MS_OLDUSERLICENSE File that contains old user license information. Required for when installing a product upgrade.
    MS_OLEDBMAXDATA See Setting Up the Database Interface
    MS_OPENDESIGNFILEFILTER Initial file filter list for the File Open and Open dialogs.
    MS_OPENREFFILEFILTER Initial file filter for the Attach Reference File dialog.
    MS_ORACLEPREFETCH Specifies the number of rows pre-fetched from the database, maximum 65535. For example if MS_ORACLEPREFETCH is set to 1000, there will be 1000 rows of data returned to the client and cached. If this configuration Variablenname is not set, one row is pre-fetched. Setting MS_ORACLEPREFETCH can result in improved query performance over high latency networks, such as Wide Area Networks (WANs).
    MS_PLOTBORDER_TIME_FORMAT Changes the date and time format for printed outputs from Windows Regional Settings to another format. Set to v7.0 to use the v7.0 format.
    MS_REFCOLORTABLE If defined and set to 1, always uses the reference's color table. If defined and set to any value other than 1, never uses the reference's color table. If not defined, uses the user preference to determine whether or not to use the reference's color table. You need to close and restart in order for this configuration Variablenname change to take effect
    MS_RIGHTLOGICKB If set to 1, keyboard input is right to left.
    MS_RSRC Main resource file. Typically set to "ustation.rsc."
    MS_SESSION_DEBUG Used to start session debug prior to the loading of the database server. By setting this configuration Variablenname, you can receive immediate debug information from the consumer DLL. MS_SESSION_DEBUG can be used with all the database servers. A value of 1 enables receipt of debug information from the database server and the corresponding DLL — ORACLE, ODBC, or OLEDB. A value of 0 enables receipt of debug information only from the DLL.
    MS_SHEETDIR Specifies the default folder path that should open when you click the Browse Sheet File or Create New Sheet File icons in the Create Drawing dialog.
    MS_SIGNATURE_DISPLAY_UNVERIFIED Controls how an unverified digital signature is crossed out. Value is color weight style strikeout where:
    color = a number, specifying the menu color identifier number
    weight = a number specifying the line weight of the annotation
    style = a number specifying the style
    strikeout = how to strike out the signature
    • "X" Draw an X over the signature
    • "—" Draw a line through the middle of the signature

    The default is a heavy solid red X over the signature. This is represented by 4 7 0 X
    To draw a heavy solid blue line through the signature, use the following: 1 7 0 —.

    MS_SIGNATURE_DELETE_REQUIRES_PRIVATE_KEY If set, you may not delete a digital signature unless you possess the private key that was used to create the signature. The default is 0.
    MS_SIGNATURE_SHOW_FULL_NAME If on, displays the full subject and issuer name from the signer's certificate in the Properties balloon for a digital signature element.
    MS_SMARTSOLID Specifies the directory path for the SmartSolid subsystem.
    MS_SNAP_TANGENT_POINT_DEFAULT_MODE The snap mode used to compute the location of a perpendicular or tangent point snap. Applies only when perpendicular or tangent point is the default snap mode. Possible values are:
    b - bisector
    i - intersection
    k - keypoint
    m - midpoint
    m1 - multisnap1
    m2 - multisnap2
    m3 - multisnap3
    The default is 'k' (keypoint).
    MS_TEXT_AUTOSTACKFRACTIONS_ALIGNMENT Sets the alignment for stacked fractions, when the Fractions advanced text style setting is on. Values are:
    1 = Top
    2 = Center (Normal for DWG files. The default if the configuration Variablenname is not defined.)
    3 = Bottom
    MS_TEXT_AUTOSTACKFRACTIONS_TYPE Sets the type for stacked fractions, when the Fractions advanced text style setting is on. Values are:
    1 = Normal
    2 = Diagonal (Normal for DWG files. The default if the configuration Variablenname is not defined.)
    Normal Center
    MS_TEXT_STACKFRACTIONS_SCALE The value is the percentage scale factor for stacked fractions. (70 is normal for DWG files, and is the default if this configuration Variablenname is not defined.)
    MS_THUMBNAIL If this Variablenname is not defined, the product looks for a saved view called "Preview," and if found uses that saved view's settings (model, orientation, render mode, etc.) to create the thumbnail. If the Variablenname is defined, the product takes whatever the Variablenname is set to and looks for a saved view of the same name. If the specified saved view name cannot be found, then the system creates/updates the thumbnail image using the view that was active at the last time you selected File > Save Settings.
    The latter also occurs if the Variablenname is not defined and if the saved view called "Preview" does not exist in any design, drawing, or sheet model in the DGN file. If this Variablenname is set to "NONE," then no new thumbnail is generated. If a thumbnail already exists in the DGN file, setting this Variablenname to "NONE" does not remove what already exists in the DGN file; it simply does not update what already exists.
    MS_USERLICENSE File containing user license information.
    MS_USERPREF User preference resource file.
    MS_USERPREF_APPS Set by application configuration files to add user preferences to standard dialogs.
    MS_VISEDGES_OMIT_EDGES_BETWEEN_PLANAR_FACES If set to 1, the interior edges between adjacent planar faces will be omitted even if the Remove Smooth Edges check box is off. This may be desirable for meshes imported from external formats that do not correctly display the interior edges between mesh faces.
    MS_VISEDGES_PRESERVE_UPDATE_SEQUENCE If set to 1, when you export the visible edges, the references are displayed in the sequence set in the Update Sequence dialog.
    MS_VIEWATTRIBUTES_PLUGINASSEMBLIES List of assemblies to search in for View Attributes dialog plug-in groups.
    PZIP_OUT Specifies default directory for creation of Packager files.




    top

    Not listed or undocumented Configuration Variablennames

    VariablennameDetailierte Beschreibung
    MS_TASKNAVIGATION_CONFIGURATION When this Variablenname is set to 1 the Task Navigation Category is displayed in Preferences Dialog. This preference category is hidden by default.
    MS_CULTURE The configuration Variablenname MS_CULTURE allows you to select the language of installed language packs to be used.
    If the configuration Variablenname MS_CULTURE is set, the language selection from Preferences dialog is dimmed.
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -

    top




    See Also

    How to create a list of all CONNECT Edition Configuration Variablennames
    How to export CONNECT Edition configuration Variablenname values to a text file

    MicroStation V8i Variablennames

    Sehen Sie hierzu auch

    X

    Englischsprachige Quelle

    MicroStation CONNECT Edition Configuration Variables

      Ursprünglicher Autor: Yvonne Lohse
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies