You are currently reviewing an older revision of this page.
Microstation 08.11.09.459.
User cannot edit images, edit handles are not visible.
Check the Disable Handles option in the Tool Settings dialog, when Element Selection tool is active.
Try deleting your temporary files first, and then, if the problem persists, recreate a new user preference file.
To delete your temp files
1. Type the following key-in inMicrostation: $ % explorer $(MS_TMP) This will open windows explorer showing the content of your temp folder.
2. Close Microstation but keep the windows explorer window open.
3. Delete all files in the temp folder
4. Restart Microstation and check if the issue still occurs.
To re-create a new clean user preferences file:
1. Type in the following key-in: $ % explorer $(_USTN_HOMEPREFS)
This will open windows explore showing the content of your user preferences folder
3. In the explorer windows look for a file with the .upf extension and rename it to a different extension (i.e. userpref.upf -> userpref.bak)