Unhandled exception message during Printer Driver converting process


  
 Applies To 
  
 Product(s):MicroStation
 Version(s):08.11.09.459
 Environment: N/A
 Area: Printing
 Subarea: 
 Original Author:Frank Reimann, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

The following message appears during the Printer Driver converting process, after trying to open a old style *.plt Printer Driver :

Unhandled exception has occurred in a component in your application. If you click Continue, the application will ignore this error and attempt to continue.

Object reference not set to an instance of an object.

 

Reason

The SIZE record in the *.plt printer driver needs a minimum setting: /units=mm

Steps to Resolve

Add /units=mm to the SIZE record (save the *.plt file) and start converting the *.plt file once again

Example:

size=(297,210) /units=mm /num=26/off=(-5.5,-5.5) /name=a4 ; DIN A4

See Also

http://communities.bentley.com/products/microstation/microstation_printing/w/wiki/using-microstation-plot-driver-to-create-and-convert-printer-driver-configuration-files.aspx