Problem

Saved Views are working inconsistently with Dynamic views.

e.g.
Reference dynamic view onto the plan and add a grid file as a 2D reference to the plan.
Reference this plan onto a sheet and the grid will show up as missing (even if all files are in the same folder.

Solution

MS_RFDIR has been limited to 20 folders in its search path.User had locked out Relative and Full Path search and as the Grid folder was number 21 in the reference search list, it would not display. When the relative paths were re-instated the problem was solved.