Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
MicroStation
  • Product Communities
MicroStation
MicroStation Wiki Line styles from reference appear as style Continuous
    • Sign In

    • -MicroStation Wiki
      • +Learning Tips
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • +CONNECT Advisor - MicroStation
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • +Cells - MicroStation
        • +Change Tracking - MicroStation
        • +Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • -DWG - MicroStation
          • +Dimensions - DWG - MicroStation
          • +Edit - DWG - MicroStation
          • -General - DWG - MicroStation
            • 3D LineStrings are becoming planar when saved to DWG
            • AutoCAD PGP Files
            • Bentley CONNECT Edition - Autodesk RealDWG(TM) FAQ
            • Bentley V8i (SELECTseries 4) - Autodesk® RealDWG™ 2016 FAQ
            • Bentley V8i - Autodesk RealDWG(TM) FAQ
            • Cannot Copy/Paste Block from DWG to DGN
            • Cannot open Civil3D DWG fully in Microstation.
            • Civil 3D 2022 Object Enabler failure message when opening DWG files
            • Crash when opening any file - Windows error message
            • Creating a DWG Viewport using MicroStation
            • DGN - DWG Terminology
            • DGN reference files in DWG work mode
            • Disable autosave for DWG/DXF files
            • Display of some text in DWG viewports is not scaling correctly
            • DWG DXF Units Alert Box
            • DWGs created in AutoCAD Plant 3D cannot be displayed as Solid
            • Enable "RealDWG 2016" Update for DWG 2015/2016 format in SS3/SS4
            • Having saved my DGN to DWG why am I seeing duplicate Layers with ( Construction )
            • How to attach an ECW raster image to a DWG file within MicroStation?
            • How to download Autodesk REALDWG
            • How to get the DWG units alert box back
            • How to store DWG settings that will be used on a number of files.
            • In a DWG drawing with clipped reference
            • Line Styles And DWG Files
            • Line styles from reference appear as style Continuous
            • Microstation J support for AutoCAD 2004/2005
            • OHM symbol in blocks in DWG is not displayed correctly in V8i
            • Open views do not retain open after closing and reopening DWG
            • Option Save relative path in MS XM when working with DWG is not available
            • Place line string using ACAD line type
            • Prefix \ not working for DWG key-ins
            • RealDWG(TM) [TN]
            • Reference DXF into DXF capability
            • Referencing 3D DWG files to 2D design files elements are not correctly display
            • Supported AutoCAD Keyins
            • When in a DWG the sheet model does not show linestyles
            • Which MicroStation version supports which DWG/DXF version formats?
            • Will MicroStation support the .dwf format?
            • Would like to set up Workspace so DWG/DX...
          • +Open - DWG - MicroStation
          • +Raster - DWG - MicroStation
          • +Save - DWG - MicroStation
          • +Text - DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • +FAQ - MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MicroStation
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MicroStation
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • +Reference - MicroStation
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • +i.Models - MicroStation
        • +ProjectWise Integration
        • +Raster - MicroStation
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Programming Wiki
    • +Visualization Wiki

     
     Questions about this article, topic, or product? Click here. 

    Line styles from reference appear as style Continuous

      Product: MicroStation
      Version: V8, V8i, CONNECT Edition
      Environment: N\A
      Area: DWG
      Subarea: General

    Problem

    Line styles from reference appear as continuous line style in dwg file

    Solution

    DWG file has reference attached, but the line styles from the reference file appear as Continuous.

    Setting the scale globally may remedy this issue:

    Key-in: ACTIVE LINESTYLESCALE (scale value).

    If it does not resolve the issue check the reference line style name in the Level Manager and Line style pull down.

    If the line style name has the reference file name, a vertical bar, then the line style name, the file will not open in AutoCAD (Invalid line style name) and the line styles will not appear correctly in MicroStation.

    This happens when the line styles in the reference file are not loaded in the master file, before the reference is attached.

    Two methods for resolving this issue:

    1. Ensure the line style is loaded in master file, then change the bylevel style for the reference file to the actual line style name (Change reflHidden to Hidden)

    2. Delete the reference, compress unused line styles to purge bad line style names from file, import line styles from .lin, reattach reference.

    See Also

    Setting Line Style Scale in MicroStation V8

    Other language sources

      Original Author: Bentley Technical Support Group
    • MicroStation
    • Migrated
    • linestyles
    • DWG
    • SELECTsupport
    • Share
    • History
    • More
    • Cancel
    • Elisabeth Pry Created by Bentley Colleague Elisabeth Pry
    • When: Fri, May 23 2014 7:14 AM
    • Andrew Bell Last revision by Bentley Colleague Andrew Bell
    • When: Sun, Aug 25 2019 8:45 PM
    • Revisions: 9
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies