Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
MicroStation
  • Product Communities
  • More
MicroStation
MicroStation Wiki How to have MicroStation automatically shutdown (Idle Time Out)
    • Sign in
    • -MicroStation Wiki
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • +CONNECT Advisor - MicroStation
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • +Cells - MicroStation
        • +Change Tracking - MicroStation
        • -Configuration - MicroStation
          • +DGN Settings - Configuration - MicroStation
          • -General - Configuration - MicroStation
            • All memory is not being used - how do I improve performance?
            • Change the backup behavior to save to original DGN file folder
            • Configuration Explorer is not showing any installed CONNECT applications
            • Context menu too long
            • Convert S01 to M01 and modify
            • Custom interface not showing tools
            • Default size for defining Configuration Variables
            • Display all configuration variables
            • Edit the extensions listed in 'Files Of Type' option
            • Enable V8i Task Theme in MicroStation CONNECT Edition
            • Error "Unable to load dialog whose id is -47" returned when attempting to open Level
            • Error expanding variable MS_LIBRARY_PATH. Exiting
            • Error message "Expanded line too long" when opening file.
            • Error message that says could not load DITEM53
            • Error when starting MicroStation--unable to resolve Digital Signature
            • Error: Fault exception set to 'none
            • Export Configuration variable values to a text file
            • How can I make MicroStation wait for predetermined amount of time
            • How do I control the generation of Thumbnails?
            • How to create a list of all CONNECT Edition Configuration Variables
            • How to Create a Windows System Variable.
            • How to disable ProjectWise integration when MicroStation is launched from desktop
            • How to find out what type of ".ma" file is causing an error.
            • How to have MicroStation automatically shutdown (Idle Time Out)
            • How to only load project specific colorbooks
            • How to remove color table stored internally on a file and attaching a new one?
            • How to set the right/left buttons of a mouse to Dynamic Pan
            • How to Start MicroStation "As Administrator"
            • How to stop all hints from displaying in MicroStation V8 XM Edition
            • How to use a variable in a key-in
            • HTML Engineering Links running in dual application windows
            • Key-in that contains a configuration variable
            • MDL Loader: Could not load application MDLAPPS\DCSTMCORE.MA
            • MicroStation CONNECT Edition Configuration Variables
            • MicroStation hangs on startup after Windows 10 Update (Spring Creator) has been installed
            • MicroStation has started displaying pop ups about the software being idle and will be shutdown
            • MicroStation v8 does not open the email client if Lotus Notes is used as the default email system.
            • MicroStation VBA crashes on startup after Microsoft Office 365 monthly/current channel updates
            • MS_LEGACYDRAWORDER and V8i or CONNECT
            • Open document using Key-in combined with variable
            • Opening a a dgn file from windows into a previously open session
            • Preventing "Not Responding" message
            • Remove Design History
            • Remove toolboxes "Clash Detection" and "Schedule Simulation"
            • Renamed configuration file (CFG) still loading
            • Select local Active Directory Server Using Windows System Variables
            • Setting MS_DESIGNSEED not working
            • Standards Checker not showing "Settings Name"
            • Toolbox not displaying when selected from Tool Boxes dialog
            • Tools missing from Tools menu
            • Turn off the "Assign Project" window in MicoStation
            • Unable to resolve mdlBspline_createCurve from lib
            • User account to use to run this program?.
            • User wants to be able to use an Environment Variable for Raster Images
            • Using an Outdated Version of MicroStation?
            • What configuration changes have been made in MicroStation CONNECT Edition?
            • What is the MicroStation High Security shortcut used for?
            • Why is configuration variable MS_FILEHISTORY locked and set to 0?
          • +User Preferences - Configuration - MicroStation
          • +Workmodes - Configuration - MicroStation
          • +WorkSet - Configuration - MicroStation
          • +Workspaces - Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • +DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • +FAQ - MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MICROSTATION
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MICROSTATION
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • +Reference - MicroStation
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • +i.Models - MicroStation
        • +Raster - MicroStation
      • +Tips & Tricks
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Programming Wiki
    • +Visualization Wiki

    You are currently reviewing an older revision of this page.

    • History View current version

    How to have MicroStation automatically shutdown (Idle Time Out)

       
      Applies To 
       
      Product(s): MicroStation / PowerDraft
      Version(s): V8 2004, V8 XM, V8i, CONNECT
      Environment:  N\A
      Area:  Configuration
      Subarea:  General
      Original Author: Bentley Technical Support Group
       

    Problem

    Request for MicroStation, or applications built on the MicroStation platform, to be able to shutdown automatically after passage of a predetermined amount of time.

    Solution

    MicroStation V8 2004 Edition, V8 XM, V8i, CONNECT and platform based applications

    A built-in configuration variable MS_IDLETIMEOUT has been included that allows you to define a set amount of idle time after which MicroStation will shut down. A minimum of 30 minutes can be used within this configuration variable and if set to 0 the software will never exit, even if idle.

    When defined time period of non-use or idleness has been reached a dialog box will appear advising MicroStation will be terminating in 60 seconds. If you click on the OK button you can continue to work, otherwise MicroStation will then shut down.

    Ideally this variable should be controlled by the site configuration, it is generally an option that would be applied across a whole organization or workgroup.

    To set the time out to 30 minutes (the minimum) add the following line to the site configuration, to standards.cfg or it's equivalent.

    MS_IDLETIMEOUT = 30

    The default location for standards.cfg is C:\ProgramData\Bentley\.....\WorkSpace\Standards

    In a networked workspace add this variable to the site configuration.

    To enforce a time out period the variable can be locked at site level by adding a %lock statement:

    MS_IDLETIMEOUT = 30

    %lock MS_IDLETIMEOUT

    Notes

    MS_IDLETIMEOUT only takes effect during an Active application session, i.e. if a DGN file is open.

    If DGN file is closed and an application is left at a file open dialog MS_IDLETIMEOUT will not have any effect.

    Users should still be advised to close applications when they do not need to use them.

    MicroStation V7 or /J

    The Idle tool for these older versions "idle.ma" is available on request from technical support staff.

    Other Language Sources

    Español Français

    See Also

    Road and Site Design - Idle Timeout

    Product TechNotes and FAQs

    External Links

    Bentley LEARN Server

    Comments or Corrections?

    Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies