Problem

What keywords in an InterPlot Design Script will work with MicroStation SS3 and Print/Print Organizer?
 

Solution


Keywords Not Implemented

With this release, several design script keywords have not been implemented. You do not have to remove these keywords from your existing design scripts, since they will not trigger any design script compilation errors.
The following assignment keywords are not implemented:
extract_envr_variable, extract_envr_value, ip_logical_index, level, pattern, and pattern_color.
The following character assignment keywords are not implemented:
ip_data_rescale, ip_data_rescale_x, ip_data_rescale_y, ip_display, ip_environment, ip_fast, ip_fence, ip_levels, ip_nodisplay, ip_nofast, ip_qpr_options, ip_region, ip_rendering_attributes, ip_short _rendering_attributes, and ip_volume.
The following active rendition keywords are not implemented:
action_item, action_type, action_name, action_spec, action_range, action_instance, sheet_name, ignore_engineering_links, ignore_custom_links, ignore_all_links, bookmark_template, first_time, element_url, element_url_description, pdf_x_measure_scale_factor, pdf_y_measure_scale_factor, u3d_bgcolor, pw_component_property_name,
pw_sheet, pw_component_property_value_integer, pw_component_property_value_character, pw_component_property_value_real,pw_component_class_name, pw_component_business_key, pw_current_file_url,
pw_master_file_url, pw_plan_set_file_url, pw_file_url_type, property_name, property_setvalues, property_setqueryvalues,
property_getvalue, property_deleteattributes, and property_maptoelement.