You are currently reviewing an older revision of this page.
How to set Selection tool to Individ/NewHow to set Element selection tool to Method "Individual" and Mode "New".History:When using Element Selection, it is often requested to reset the optionsto the default values of Mode = New and Method = Individual the tool isrestarted.Product: MicroStation V8 XM EditionVersion: 08.09.04.51Area: General, DEFINEDSTEPSSee Also: Help on Workspace > Customize
Customize the tool to include the key-ins to set the desired settings.To set Element Selection mode to New:Key-in: POWERSELECTOR MODE NEWTo set Element selection Method to Individual:Key-in: POWERSELECTOR SINGLEString them together with the command to start Element Selection asfollows:POWERSELECTOR MODE NEW;POWERSELECTOR SINGLE;CHOOSE ELEMENTReplace this command in a custom version of Element Selection.Note: Refer to help documentation for more information on Custom tools.