Path does not exist.When selecting another project I get the following error:<(><<)>path>Path does not existsCheck the path and try again.
Find project and move to project folder.Cause of error:The project folder was moved/deleted from where the projects are defined.ORThe variable _USTN_PROJECTROOT was redirected to a location that does not contain the project folders of the selected project.Now to resolve:1. Check the name of the project that was selected.2. Search system for the project file matching the selected project name.Note: There is no good way to know where the project files used to be.3. Once/if found, go to location of projects (_USTN_PROJECTROOT).4. Move project folder (in step #2) to projects location (step #3).Note: If project folders were confirmed to be deleted, then the associated project configuration file should also be removed so that a project without project folders is not selectable in the project list in MicroStation Manager. The location of Project configuration files are defined by _USTN_PROJECT.