Product: | MicroStation | ||
Version: | 08.11.07.443 | ||
Environment: | N\A | ||
Area: | Configuration | ||
Subarea: | Workspaces |
Path does not exist.
When selecting another project I get the following error:
<(><<)>path>
Path does not exists
Check the path and try again.
Find project and move to project folder.
Cause of error:
The project folder was moved/deleted from where the projects are defined.
OR
The variable _USTN_PROJECTROOT was redirected to a location that does not contain the project folders of the selected project.
Now to resolve:
1. Check the name of the project that was selected.
2. Search system for the project file matching the selected project name.
Note: There is no good way to know where the project files used to be.
3. Once/if found, go to location of projects (_USTN_PROJECTROOT).
4. Move project folder (in step #2) to projects location (step #3).
Note: If project folders were confirmed to be deleted, then the associated project configuration file should also be removed so that a project without project folders is not selectable in the project list in MicroStation Manager. The location of Project configuration files are defined by _USTN_PROJECT.