Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
MicroStation
  • Product Communities
MicroStation
MicroStation Wiki MicroStation V8i SELECTseries 2 Resolved Issues
    • Sign In

    • -MicroStation Wiki
      • +Learning Tips
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • +CONNECT Advisor - MicroStation
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • +Cells - MicroStation
        • +Change Tracking - MicroStation
        • +Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • +DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • -FAQ - MicroStation
          • Get to know MicroStation CONNECT Edition
          • +History of MicroStation
          • MicroStation CONNECT Edition Frequently Asked Questions
          • MicroStation CONNECT Edition System Requirements
          • MicroStation CONNECT Edition Trial Version System Requirements
          • MicroStation Known Issues [FAQ]
          • MicroStation V8i SELECT series 4 [FAQ]
          • MicroStation V8i [FAQ]
          • Resolved Issues in MicroStation CONNECT Edition Update 13, 10.13.00.48
          • Resolved Issues in MicroStation CONNECT Edition Update 12, 10.12.00.40
          • Resolved Issue in MicroStation CONNECT Edition Update 11, 10.11.00.36
          • Resolved issues in MicroStation CONNECT Edition Update 10, 10.10.00.23
          • Resolved issues in MicroStation CONNECT Edition Update 9, 10.09.01.01
          • Resolved issues in MicroStation CONNECT Edition Update 8, 10.08.00.37
          • Resolved issues in MicroStation CONNECT Edition Update 7
          • Resolved issues in MicroStation CONNECT Edition Update 6
          • Resolved issues in MicroStation CONNECT Edition Update 5
          • Resolved issues in MicroStation CONNECT Edition Update 4
          • Resolved Issues in MicroStation CONNECT Edition Update 3
          • Resolved issues in MicroStation CONNECT Edition Update 2
          • Resolved issues in MicroStation CONNECT Edition Update 1
          • MicroStation V8i SELECTseries 4 Resolved Issues and Bug Fixes
          • MicroStation V8i SELECTseries 2 Resolved Issues
          • MicroStation V8 XM Edition [FAQ]
          • Resolved issues for MicroStation CONNECT Edition 17.2
          • Resolved issues in MicroStation CONNECT Edition Update 14, 10.14.00.109
          • Resolved issues in MicroStation CONNECT Edition Update 15 (10.15.00.74)
          • Resolved issues in MicroStation CONNECT Edition Update 15 (10.15.02.11)
          • Resolved issues in MicroStation CONNECT Edition Update 16 (10.16.00.80)
          • Resolved issues in MicroStation CONNECT Edition Update 16.1 (10.16.01.56)
          • Resolved issues in MicroStation CONNECT Edition Update 17 (10.17.00.209)
          • TeamViewer Remote Desktop with MicroStation
          • Using MicroStation in Azure Windows Virtual Desktop
          • +Working from home with MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MicroStation
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MicroStation
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • +Reference - MicroStation
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • +i.Models - MicroStation
        • +ProjectWise Integration
        • +Raster - MicroStation
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Printing and Plotting
    • +Programming Wiki
    • +Visualization Wiki

     
     Questions about this article, topic, or product? Click here. 

    MicroStation V8i SELECTseries 2 Resolved Issues

       
      Applies To 
       
      Product(s): MicroStation
      Version(s): 08.11.07.492
      Environment:  N\A
      Area:  FAQ
      Subarea:  N\A
      Original Author: Bentley Technical Support Group
       

    Problem

    Fixed 08.11.07.443 - 08.11.07.492
    What is fixed between 08.11.07.443 and 08.11.07.492 ?

    Product: MicroStation V8i
    Version: 08.11.07.492
    Area: Fundamentals, GENERALINFORMATION

    Solution

    Here is the list:
    311031 - [Geographic Coordinate System] Sweden coordinate system SWEREF
    99 18 00 has slightly different definition (inverted axis) than
    EPSG:3011 while internally mapped one to the other.

    310640 - Request for Geographic Coordinate System for Singapore (SVY 21)

    261423 - The "Move to Contact" tool does not move all elements as
    expected

    287864 - Incorrect angles are being reported with the Label Line tool.

    307960 - When publishing an AutoPLANT model - some of the elements come
    across as AutoPLANT dgn types - so they require the AP element handler.

    312197 - Using hpglrtl.pltcfg with Border On = true, any Border text \
    comment = true, and Fence outline on = true, the fence outline prints at
    the correct origin (0,0). However, the drawing is printed with a 3/8
    inch offset.

    312060 - Move to Contact tool is bypassing elements for text elements.

    310531 - When we export a DGN file to a Collada file, the result is not
    correct.

    311821 - Crash after using Insert Dimension tool with existing dimension
    on Cone element

    313423 - After installation of PWG Admin when creating BG Map from
    remote XP machine, getting MMC crash error.

    313357 - The displayed markups are not automatically detached when the
    file is closed in MicroStation.

    313377 - The markup Display On check indicators are not persisted
    between versions.

    314364 - Merge into Master impossible

    313819 - DWG export: external attachments - merged to cells - are
    missing

    310331 - IPLOT can't plot elements with tags. The plot / preview process
    is resulting in a exception log

    314223 - Memory not releasing in Batch Process for Materials.

    315267 - Wrong scaled tags nested in shared cells

    D-81218 - Relationships are lost after doing DesignHistoryRevert

    291715 - Ms Crash assigning a saved view to a view with "Window" option
    selected.

    308911 - Significant degradation in performance of Print Organizer when
    working with PW managed workspaces.

    316098 - ProjectWise MCM checkin cause MicroStation crash due to NULL
    model ref pointer when there is no active design file.

    314449 - WMS doesn't manage custom GCS as expected

    D-82210 - I-models cannot be processed if they are located over a
    network path.

    316171 - A fatal error has occurred when "Discarded Invalid Entities" is
    enabled.

    • Migrated
    • SELECTsupport
    • Share
    • History
    • More
    • Cancel
    • Dan Abney Created by Bentley Colleague Dan Abney
    • When: Wed, Jul 9 2014 1:32 PM
    • Marc Thomas Last revision by Bentley Colleague Marc Thomas
    • When: Thu, Oct 10 2019 10:49 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies