<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>How to suppress zero feet/inch in DWG file?</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file</link><description>Bentley View, MicroStation, PowerDraft</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to suppress zero feet/inch in DWG file?</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file</link><pubDate>Wed, 02 Aug 2017 01:48:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dc3798c5-fb6c-4efb-ae75-ec4ecc82641b</guid><dc:creator>Andrew Bell</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file#comments</comments><description>Current Revision posted to MicroStation Wiki by Andrew Bell on 8/2/2017 1:48:51 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MICROSTATION&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.05.00.64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Dimensions&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Dim Styles&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p&gt;How to suppress zero feet/inch in DWG file?&lt;br /&gt;Leading Zero option does not work in DWG file.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;In AutoCAD it is called &amp;quot;Suppress Zero Inch&amp;quot; and can be accessed in the Dimension Style dialog box. In MicroStation, the &amp;quot;display sub units&amp;quot; flag must be turned on.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Zero Sub Unit suppression:&lt;/strong&gt;&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp(mdlDimStyle_getActive (), X, 1078)&lt;br /&gt;X=1 means show the Sub Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Sub Unit value even if it is zero.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Zero Master Unit suppression:&lt;/strong&gt;&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp(dgnDimStyle_getActiveFromModelRef (0), X, 1041)&lt;br /&gt;X=1 means show the Master Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Master Unit value if it is zero.&lt;br /&gt;&lt;br /&gt;Notes:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &amp;quot;Leading Zero&amp;quot; option in MicroStation is not the same as&amp;nbsp;suppressing zero inches in DWG files.&lt;/li&gt;
&lt;li&gt;This will change the active dimension setting, but will not change any&amp;nbsp;existing dimensions in the file. Use &amp;quot;Change Dimension&amp;quot; tool to update&amp;nbsp;dims to current setting.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Migrated, SELECTsupport&lt;/div&gt;
</description></item><item><title>How to suppress zero feet/inch in DWG file?</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file/revision/5</link><pubDate>Mon, 29 Sep 2014 12:35:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dc3798c5-fb6c-4efb-ae75-ec4ecc82641b</guid><dc:creator>AnuKuu</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file#comments</comments><description>Revision 5 posted to MicroStation Wiki by AnuKuu on 9/29/2014 12:35:45 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="width:500px;background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MICROSTATION&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.05.00.64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Tools&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p&gt;How to suppress zero feet/inch in DWG file?&lt;br /&gt;Leading Zero option does not work in DWG file.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;In AutoCAD it is called &amp;quot;Suppress Zero Inch&amp;quot; and can be accessed in the Dimension Style dialog box. In MicroStation, the &amp;quot;display sub units&amp;quot; flag must be turned on.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Zero Sub Unit suppression:&lt;/strong&gt;&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp(mdlDimStyle_getActive (), X, 1078)&lt;br /&gt;X=1 means show the Sub Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Sub Unit value even if it is zero.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Zero Master Unit suppression:&lt;/strong&gt;&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp(dgnDimStyle_getActiveFromModelRef (0), X, 1041)&lt;br /&gt;X=1 means show the Master Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Master Unit value if it is zero.&lt;br /&gt;&lt;br /&gt;Notes:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &amp;quot;Leading Zero&amp;quot; option in MicroStation is not the same as&amp;nbsp;suppressing zero inches in DWG files.&lt;/li&gt;
&lt;li&gt;This will change the active dimension setting, but will not change any&amp;nbsp;existing dimensions in the file. Use &amp;quot;Change Dimension&amp;quot; tool to update&amp;nbsp;dims to current setting.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Migrated, SELECTsupport&lt;/div&gt;
</description></item><item><title>How to suppress zero feet/inch in DWG file?</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file/revision/4</link><pubDate>Mon, 29 Sep 2014 12:35:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dc3798c5-fb6c-4efb-ae75-ec4ecc82641b</guid><dc:creator>AnuKuu</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file#comments</comments><description>Revision 4 posted to MicroStation Wiki by AnuKuu on 9/29/2014 12:35:26 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="width:500px;background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MICROSTATION&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.05.00.64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Tools&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p&gt;How to suppress zero feet/inch in DWG file?&lt;br /&gt;Leading Zero option does not work in DWG file.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;In AutoCAD it is called &amp;quot;Suppress Zero Inch&amp;quot; and can be accessed in the Dimension Style dialog box. In MicroStation, the &amp;quot;display sub units&amp;quot; flag must be turned on.&lt;br /&gt;&lt;br /&gt;Zero Sub Unit suppression:&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp(mdlDimStyle_getActive (), X, 1078)&lt;br /&gt;X=1 means show the Sub Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Sub Unit value even if it is zero.&lt;br /&gt;&lt;br /&gt;Zero Master Unit suppression:&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp(dgnDimStyle_getActiveFromModelRef (0), X, 1041)&lt;br /&gt;X=1 means show the Master Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Master Unit value if it is zero.&lt;br /&gt;&lt;br /&gt;Notes:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &amp;quot;Leading Zero&amp;quot; option in MicroStation is not the same as&amp;nbsp;suppressing zero inches in DWG files.&lt;/li&gt;
&lt;li&gt;This will change the active dimension setting, but will not change any&amp;nbsp;existing dimensions in the file. Use &amp;quot;Change Dimension&amp;quot; tool to update&amp;nbsp;dims to current setting.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Migrated, SELECTsupport&lt;/div&gt;
</description></item><item><title>How to suppress zero feet/inch in DWG file?</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file/revision/3</link><pubDate>Mon, 29 Sep 2014 12:34:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dc3798c5-fb6c-4efb-ae75-ec4ecc82641b</guid><dc:creator>AnuKuu</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file#comments</comments><description>Revision 3 posted to MicroStation Wiki by AnuKuu on 9/29/2014 12:34:35 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="width:500px;background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MICROSTATION&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.05.00.64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Tools&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p&gt;How to suppress zero feet/inch in DWG file?&lt;br /&gt;Leading Zero option does not work in DWG file.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;In AutoCAD it is called &amp;quot;Suppress Zero Inch&amp;quot; and can be accessed in the Dimension Style dialog box. In MicroStation, the &amp;quot;display sub units&amp;quot; flag must be turned on.&lt;br /&gt;&lt;br /&gt;Zero Sub Unit suppression:&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp&lt;br /&gt;(mdlDimStyle_getActive (), X, 1078)&lt;br /&gt;X=1 means show the Sub Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Sub Unit value even if it is zero.&lt;br /&gt;&lt;br /&gt;Zero Master Unit suppression:&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp&lt;br /&gt;(dgnDimStyle_getActiveFromModelRef (0), X, 1041)&lt;br /&gt;X=1 means show the Master Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Master Unit value if it is zero.&lt;br /&gt;&lt;br /&gt;Notes:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &amp;quot;Leading Zero&amp;quot; option in MicroStation is not the same as&amp;nbsp;suppressing zero inches in DWG files.&lt;/li&gt;
&lt;li&gt;This will change the active dimension setting, but will not change any&amp;nbsp;existing dimensions in the file. Use &amp;quot;Change Dimension&amp;quot; tool to update&amp;nbsp;dims to current setting.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Migrated, SELECTsupport&lt;/div&gt;
</description></item><item><title>How to suppress zero feet/inch in DWG file?</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file/revision/2</link><pubDate>Mon, 29 Sep 2014 12:33:40 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dc3798c5-fb6c-4efb-ae75-ec4ecc82641b</guid><dc:creator>AnuKuu</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file#comments</comments><description>Revision 2 posted to MicroStation Wiki by AnuKuu on 9/29/2014 12:33:40 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="width:500px;background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MICROSTATION&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.05.00.64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Tools&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p&gt;How to suppress zero feet/inch in DWG file?&lt;br /&gt;Leading Zero option does not work in DWG file.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;In AutoCAD it is called &amp;quot;Suppress Zero Inch&amp;quot; and can be accessed in the Dimension Style dialog box. In MicroStation, the &amp;quot;display sub units&amp;quot; flag must be turned on.&lt;br /&gt;&lt;br /&gt;Zero Sub Unit suppression:&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp&lt;br /&gt;(mdlDimStyle_getActive (), X, 1078)&lt;br /&gt;X=1 means show the Sub Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Sub Unit value even if it is zero.&lt;br /&gt;&lt;br /&gt;Zero Master Unit suppression:&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp&lt;br /&gt;(dgnDimStyle_getActiveFromModelRef (0), X, 1041)&lt;br /&gt;X=1 means show the Master Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Master Unit value if it is zero.&lt;br /&gt;&lt;br /&gt;Notes:&lt;br /&gt;-The &amp;quot;Leading Zero&amp;quot; option in MicroStation is not the same as&lt;br /&gt;suppressing zero inches in DWG files.&lt;br /&gt;-This will change the active dimension setting, but will not change any&lt;br /&gt;existing dimensions in the file. Use &amp;quot;Change Dimension&amp;quot; tool to update&lt;br /&gt;dims to current setting.&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Migrated, SELECTsupport&lt;/div&gt;
</description></item><item><title>How to suppress zero feet/inch in DWG fi...</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file/revision/1</link><pubDate>Mon, 04 Aug 2014 14:47:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dc3798c5-fb6c-4efb-ae75-ec4ecc82641b</guid><dc:creator>Elisabeth Pry</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/16185/how-to-suppress-zero-feet-inch-in-dwg-file#comments</comments><description>Revision 1 posted to MicroStation Wiki by Elisabeth Pry on 8/4/2014 2:47:27 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-left-width:0px;border-right-width:0px;border-bottom-width:0px;border-top-width:0px;" alt=" " src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border-top:#dce5f0 0px solid;border-right:#dce5f0 0px solid;width:500px;border-bottom:#dce5f0 0px solid;border-left:#dce5f0 0px solid;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MICROSTATION&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.05.00.64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Tools&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p&gt;How to suppress zero feet/inch in DWG file?&lt;br /&gt;Leading Zero option does not work in DWG file.&lt;br /&gt;&lt;br /&gt;Product: MicroStation V8 2004 Edition&lt;br /&gt;Version: 08.05.00.64&lt;br /&gt;Area: Dimension/Measure&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;In AutoCAD it is called &amp;quot;Suppress Zero Inch&amp;quot; and can be accessed in the Dimension Style dialog box. In MicroStation, the &amp;quot;display sub units&amp;quot; flag must be turned on.&lt;br /&gt;&lt;br /&gt;Zero Sub Unit suppression:&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp&lt;br /&gt;(mdlDimStyle_getActive (), X, 1078)&lt;br /&gt;X=1 means show the Sub Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Sub Unit value even if it is zero.&lt;br /&gt;&lt;br /&gt;Zero Master Unit suppression:&lt;br /&gt;Key-in:&lt;br /&gt;mdl load calculat; calculator mdlDimStyle_setBoolIntProp&lt;br /&gt;(dgnDimStyle_getActiveFromModelRef (0), X, 1041)&lt;br /&gt;X=1 means show the Master Unit value even if it is zero.&lt;br /&gt;X=0 means hide the Master Unit value if it is zero.&lt;br /&gt;&lt;br /&gt;Notes:&lt;br /&gt;-The &amp;quot;Leading Zero&amp;quot; option in MicroStation is not the same as&lt;br /&gt;suppressing zero inches in DWG files.&lt;br /&gt;-This will change the active dimension setting, but will not change any&lt;br /&gt;existing dimensions in the file. Use &amp;quot;Change Dimension&amp;quot; tool to update&lt;br /&gt;dims to current setting.&lt;br /&gt;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;
&lt;h1&gt;See Also&lt;/h1&gt;&lt;br /&gt;&lt;br /&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Migrated, SELECTsupport&lt;/div&gt;