Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
MicroStation
  • Product Communities
MicroStation
MicroStation Wiki Copying cells from one library to another
    • Sign In

    • -MicroStation Wiki
      • +Learning Tips
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • +CONNECT Advisor - MicroStation
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • -Cells - MicroStation
          • +Annotation Cells - Cells - MicroStation
          • +Cells Dialog - Cells - MicroStation
          • -General - Cells - MicroStation
            • Active Scale is ignored when placing Cell
            • Add arrow heads to lines or arcs
            • Attempt to place a cell from an HTML generated web page and dialog opens asking to Download or open a file
            • Can't open file with RPC cells in SS3
            • Cannot place/import cell from 3D Warehouse
            • Cell Name limit for V7 format design files
            • Cell with 'live' coordinates
            • Cells are scaled when merging a Reference
            • Cells do not appear in cell library
            • Cells with tags do not stretch
            • Convert a 3D Cell Library to 2D
            • Convert a 3D cell library to 2D in V7
            • Copying cells from one library to another
            • Create concrete hatches
            • Data fields in placed cells cannot be manipulated
            • Display order of overlapping cells is not respected
            • Exception.log msbatch + repcell
            • Fixing corrupted cells
            • Free cells or cell libraries
            • Gap between cell elements in a pattern
            • Getting "element too large" error placing cell
            • How can you change mirror settings for placing cell through keyin?
            • How can you re-order cells in a DGN file?
            • How to convert all cells in a cell library from Point Cells to Graphic Cells?
            • How to convert multiple V7 cell libaries to V8 cell libraries
            • How to create a HTML with cell images from a Cell library
            • How to create a new cell selector (.csf) for a new cell library
            • How to create AutoCAD "block libraries" from MicroStation cell libraries
            • How to create cells in Microstation V8i and Connect Edition
            • How to keep the 2D cells in a 3D file all on the same plane while moving them.
            • How to load a default Cell Selector file automatically so its loaded for all designs
            • How to make a cell view independent
            • How to Manipulate (break, delete, move,..) certain elements "XFM Features” using MicroStation
            • How to merge two cell libraries.
            • How to open a specific Cell Selector file with a keyin
            • How to place cells in a *.dgn file
            • How to prevent a V7 Cell Library (pre-V8) from being upgraded in MicroStation V8?
            • How to scale cells converted from a V7 cell library
            • How to Select all Orphan cells in a Model
            • It is not possible to create cells in a cell library
            • Keyin to open a Cell Selector file
            • Maximum size of a cell in MicroStation
            • Microstation V8i SS3 crashes when placing RPC cell
            • Modify Cells per Color and Level
            • Move the Origin of a Cell
            • Number of cell libraries in MS_CELLLIST
            • Opening a cell library through Cell Selector
            • Options to create a Line with Terminator
            • Place cells in specific location using the cell name and coordinates given by a txt file.
            • Place Cells with ByCell Attribute
            • Place Standard Cells in a DWG file
            • Placed cell does not display.
            • Placing cell from cell library with different color table
            • Point Cell's range block is larger than element
            • Relative toggle missing from the Place Active Cell tool in MicroStation CONNECT Edition
            • The cell is appearing as a box when placing, and as a phantom image when moving.
            • The differences between a graphic and point cell.
            • The line terminators are rotated 90 degrees rather than in the normal manner
            • Triforma has intentionally restricted placement and copying of this elements
            • Type 2 and Type 15 Point Cells become a Graphic Cell
            • Upgrade pre-V8 cell library View Group is not created
            • Upgrading MicroStation J cell library
            • What is an anonymous shared cell?
            • When a V7 cell library is updated in V8 some cells do not contain any elements
            • When placing a converted AutoCAD Block as a cell the origin is incorrect
            • Where are the delivered Bentley cells located
            • Where can I find Bentley's collection of example cell libraries?
            • Why do point cells always snap to the origin
          • +Parametric Cells - Cells - MicroStation
          • +Replace Cell - Cells - MicroStation
          • +Shared cells - Cells - MicroStation
        • +Change Tracking - MicroStation
        • +Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • +DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • +FAQ - MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MicroStation
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MicroStation
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • +Reference - MicroStation
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • +i.Models - MicroStation
        • +ProjectWise Integration
        • +Raster - MicroStation
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Programming Wiki
    • +Visualization Wiki

     
     Questions about this article, topic, or product? Click here. 

    Copying cells from one library to another

       
      Applies To 
       
      Product(s): MicroStation
      Version(s): 08.01.02.15
      Environment:  N\A
      Area:  Cells
      Subarea:  General
      Original Author: Bentley Technical Support Group
       

    Problem

    Copying cells from one library to another which has tags embedded into them.
    When the tags are placed they cannot be edited.

    Solution

    Using the following steps the problem could not be reproduced.

    1. File > New and created a new file.
    2. Element > Tags > Define, selected add created a new tag set.
    3. Selected add on the right and created two tags in the tag set.
    4. Using the place block tool, placed a block in the file
    5. Using the place tag tool, identified the block
    6. In the place tag tool dialog selected the tag set
    7. Set values for both tags and attached the tags to the block
    8. Element> Cells> File > New, create d a new cell library
    9. Placed a fence and cell origin around the block with attached tags.
    10. Selecting the create button, created a new cell.
    11. Created a second cell library to use a destination cell library.
    12. File > Open, opened the destination cell library as a design file.
    13. File > Models , select the import models tool
    14. Select source cell library which contained cell with tags.
    15. Select the cell to be imported.
    16. File > Open, opened up a different file
    17. Element > Cells > File > Attach, and attached cell library with imported cell
    18. Using the Place cell tool, place the cell in the file
    19. Selected the Edit Tag tool and select the tag and was able to modify the values.



    See Also



    • Cells Copy Library
    • Share
    • History
    • More
    • Cancel
    • Elisabeth Pry Created by Bentley Colleague Elisabeth Pry
    • When: Thu, Aug 28 2014 11:01 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies