Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
MicroStation
  • Product Communities
  • More
MicroStation
MicroStation Wiki Scale an Image (Raster)
    • Sign in
    • -MicroStation Wiki
      • +Learning Tips
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • +CONNECT Advisor - MicroStation
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • +Cells - MicroStation
        • +Change Tracking - MicroStation
        • +Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • +DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • +FAQ - MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MicroStation
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MicroStation
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • +Reference - MicroStation
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • +i.Models - MicroStation
        • +ProjectWise Integration
        • -Raster - MicroStation
          • After attaching raster images via I/RAS, display incorrectly in Bentley Redline
          • Attached raster is not displayed in Raster Manager
          • Attaching Displaying Raster Images In MicroStation
          • Basic Raster Editing
          • Capture key-in missing in CONNECT
          • Change Display Order of Raster
          • Command line process for converting raster images to another format
          • Dealing with error message - Raster image has 'Ignore Raster Rotation and Affinity' or/and 'View Independent' set to ON
          • Define Default Raster Scale
          • Differences of TIFF formats: Internet TIFF, Internet TIFF64, GEOTIFF
          • ECW Not Showing as Supported Raster File
          • Enable Bing Maps for use with MicroStation
          • Error when attaching MrSid and tiff images
          • How can I improve memory allocation on my PC for Raster Manager?
          • How is this file path of the mapping Image File stored in an i-model?
          • How to align accurately a raster image to existing geometry.
          • How to Attach a PDF as Reference in a DGN in MicroStation CONNECT Edition
          • How to attach a specific page of a PDF on Raster Manager
          • How to attach Image (Raster) to design model
          • How to change the order of raster files
          • How to convert format jpg to jp2 using its sister file (.jgw) in order to keep geographic information
          • How to get ECW raster format available from the Default File Type set to: Common Raster Formats
          • How to increase the raster available memory
          • How to merge an edited Image (Raster) from a Reference into the Master
          • How to place a non-georeferenced image in a precise location.
          • How to rotate 30 images in one step
          • How to save a warped raster file
          • How to share raster cache files between workstations
          • How to turn off dynamic display when warping raster
          • Image attached multiple times
          • Imported Image can not be rotated
          • Initialization of the dynamic link library rasterselect.dll failed
          • Installing Image Manager in MicroStation /J
          • Insufficient memory to read image.
          • Is there any way to export a DGN to a common graphics format?
          • Jpeg virus vulnerability
          • MDL Aborts in Image Manager
          • MDL error when attaching a raster
          • Merge pdf into a *.dgn file
          • MicroStation Crashes when attaching ECW in Win7 x64
          • Opening the Raster Manager dialog
          • Part of image is missing
          • PDF File Handling
          • PDF files with any operation restrictions are not supported
          • Problem with Batch converting jpg files to hmr
          • Raster in reference file not displaying
          • Raster caching when image is only displaying the outline
          • Raster disappears between session in MicroStation
          • Raster File Format Handling
          • Raster image does not display
          • Raster image is not displaying when dgn file is referenced into another .dgn file
          • Raster Manager
          • Raster Manager - Raster File Format Handling Backup
          • Raster Manager in MicroStation V8i [FAQ]
          • Raster Manager Not Saving Warp Image Changes
          • Raster Manager Preferences Within The MicroStation V8 Workspace
          • Raster Manager Reads GEOTIFF and World Files
          • Raster Reprojection
          • RST file does not work anymore
          • Scale an Image (Raster)
          • Server Streaming Raster Images
          • Sister file is not being used to attach Mr Sid file
          • The Ultimate Raster Border Working With Boundaries In MicroStation I RAS B [CS]
          • TIF raster in sheet model prints in black
          • To Embed a Google Earth image into a DGN file
          • Turn off creation of Thumbs.db file
          • Unable to attach Raster files in read-only DGN
          • Upgrading Your HMR Raster Attachments To MicroStation V8 [CS]
          • Washed out Raster
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Programming Wiki
    • +Visualization Wiki

    You are currently reviewing an older revision of this page.

    • History View current version

    Scale an Image (Raster)

       
      Applies To 
       
      Product(s): MicroStation
      Version(s): Varies
      Environment:  N\A
      Area:  Raster
      Subarea:  N\A
      Original Author: Craig Calvin, Bentley Technical Support Group
       

     

    How to

    Scale an image

    Background

    Fixed Aspect Ratio (Proportional)

    (e.g. Scaling x-direction will also scale y-direction proportionally to maintain the aspect ratio)

     

     

    Unfixed Aspect Ratio (Disproportionate)

    (e.g. Scale in x-direction without scaling in y-direction)

     

    Steps to Accomplish

    Option 1: Edit Handles
    Select the image
    Select an edit handle
    By default, the image will scale with a fixed aspect ratio
    Optional: Press [Alt] to unfix the aspect ratio
    Click new position of edit handle to resize
    Note: This method will work if the image's aspect ratio is set to fixed in the Geometry section of the Element Information dialog. This method does not change the "Aspect Ratio Fixed" property for the image.

    Option 2: Element Information Dialog
    Select the image
    Open the Element Information dialog
    Expand the Geometry section
    Specify if you want the "Aspect Ratio Fixed"
    Enter the scale factor for the axis you want to scale the image about

    Option 3a: Raster Manager – Active Scale Method
    Note: Images pasted into the model may not appear in the Raster Manager
    Open Raster Manager (File > Raster Manager)
    Select the raster to resize
    Select the Scale icon
    In the tool settings dialog, select Active Scale
    For Fixed Aspect Ratio: Toggle the lock icon to appear unlocked
    For Unfixed Aspect Ratio: Toggle the lock icon to appear unlocked
    Specify the scale by entering a factor in the Scale input box
    Enter a data point at the same location, whatever the scale
    All views update to reflect your scale adjustments

    Option 3b: Raster Manager – 3 Points Scale Method
    Note: Images pasted into the model may not appear in the Raster Manager
    Open Raster Manager (File > Raster Manager)
    Select the raster to resize
    Select the Scale icon
    In the tool settings dialog, select 3 Points Scale
    For Fixed Aspect Ratio: Check Proportional
    For Unfixed Aspect Ratio: Uncheck Proportional
    Enter a point to scale the raster about
    Enter a reference point
    Enter a point to define the amount of scaling

    Option 4: Scale Tool
    Open the Scale tool (Tools > Manipulate > Scale)
    Steps and tool settings are similar to Options 3a & 3b

    Option 5: Key-in
    RASTER SCALE [ACTIVE | 3POINTS | PROPORTIONAL | PROPORTIONAL ON | PROPORTIONAL OFF | PROPORTIONAL TOGGLE]

    SCALE ICON

    See Also

    MicroStation Help – Scale Raster

    MicroStation Help - Scale

    Product TechNotes and FAQs

    External Links

    Bentley Homepage
    Bentley Technical Support KnowledgeBase
    Bentley LEARN Server

    Comments or Corrections?

    Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2022 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies