Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
MicroStation
  • Product Communities
  • More
MicroStation
MicroStation Wiki Recalling the Alert box after selecting "Do Not Display Again" when detaching all references
    • Sign in

    • -MicroStation Wiki
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • +CONNECT Advisor - MicroStation
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • +Cells - MicroStation
        • +Change Tracking - MicroStation
        • +Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • +DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • +FAQ - MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MICROSTATION
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MICROSTATION
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • -Reference - MicroStation
          • 'Element is in a non-snappable Reference' message appears when trying to snap to element
          • A portion of reference file attachment is missing
          • Activate Reference option greyed out
          • Active Reference Overrides Color
          • Add relative path to reference
          • Adjust Colors Setting from Nested Reference Attachments
          • After attaching a reference the graphics not displaying correctly or not displaying at all
          • Aligning DWG reference with master file
          • Attach Reference process very slow
          • Attaching dwg 3D files to dgn 2D
          • Can you attach a reference with a UNC path
          • Can't open reference new session
          • Cannot find reference after attachment
          • Cannot rename, delete or move a file, using Windows
          • Change default attachment setting for reference linestyle scale
          • Change Working Units and Global Origin - Use Coincident Attachment Method
          • Clip Boundary inactive reference panel
          • Clip reference saved view impossible
          • Crash during True Hidden Line process.
          • Creating Multiple Reference Masks
          • Detach a Border Attachment with Key-in
          • Display Overrides setting in the reference attachment dialog box
          • Display references in a different color
          • Display Text and Dimensions in Reference Presentation
          • DWG References To DGN Files TechNote
          • Exchanging to a Reference gives different display to opening Reference directly
          • Getting "No Elements Found" message when trying to clip a reference with a Fence
          • Hatch, Cross Hatch or Pattern Hatches not displaying in Presentation Mode
          • Hidden Line Presentation mode "True Hidden Line" is not available
          • How do I remove the full path setting from my design files?
          • How to add Relative path to a Reference Attachment
          • How to adjust color using a key-in
          • How to attach a reference with a 1:1 scale without using True Scale
          • How to attach references and have their boundary display
          • How to change font size in Reference Title
          • How to control the color of reference file highlight
          • How to control the display of the viewport boundary
          • How to control view attributes in Reference Presentation
          • How to create a report of what levels are ON/OFF
          • How to create a report of which reference files are turned ON?
          • How to enable / disable Merge To Master warning dialog
          • How to Link a level to a Reference attachment
          • How to manipulate Reference Attachments as elements
          • How to modify a Reference Clip Boundary
          • How to Order Reference Attachments
          • How to produce a text file to attach reference files
          • How to Set Reference Clip Boundary FENCE
          • How to Synchronize Reference Symbology
          • How to temporarily hilite elements displayed in nested reference attachment
          • How to Turn Off Display of a Nested Reference Using a Key-In
          • How to turn off the display when attaching a Reference
          • How to turn ON / OFF reference display
          • How to turn on the Save Relative Reference path
          • How to use reference file level symbology overrides without affecting the active file levels
          • If same dwg file is referenced twice turning off display of one turns off display of both
          • Internal reference model not found after renaming
          • Is there a method to synch all the levels of all of the reference files attached?
          • Key-in to set ON "Ignore Attachment When Live Nesting" option for DWG references
          • Level name structure when merging reference files
          • Level overrides key-in with nested references
          • Line Style scale change when referenced
          • Lineweights in sheet model don't display
          • Live Nested Attachments Level Attributes And View Display
          • Losing reference attachments after reopening file
          • Make the reference file use same color table as Master
          • Maximum file name length (65 characters) MicroStation V7/J
          • Maximum Number of Clip Points
          • Maximum number of References attached to DGN
          • Maximum Number of Vertices in a Reference Clip Boundary
          • MDL Abort in MPTOOLS
          • Merge referenced into master when saving a DWG to DGN
          • Merging Reference Files During Save As
          • +MicroStation Reference File [FAQ]
          • Modify Reference boundary by handles
          • Nested references are being loaded although nest depth is set to 0
          • New Levels in my reference files does not update right away in the master file.
          • Non-Top View References do not appear correctly
          • Not possible to define a reference clipping boundary
          • Not seeing nested references
          • Open master file without references
          • Place attached Google Earth image behind elements in 2D file
          • Recalling the Alert box after selecting "Do Not Display Again" when detaching all references
          • Redundant References
          • REF2RCD: Fails to detach reference files
          • Reference Activate
          • REFERENCE ATTACH key-in opens the Reference dialog
          • Reference attachment is red.
          • Reference clip display gone when turning off Level containing the reference clip boundary element.
          • Reference Clip Vertex Limit for V7 Format
          • Reference Display Behavior In DWG Workmode [TN]
          • Reference elements are missing in file
          • Reference File levels not remaining turned on after performing a Copy View
          • Reference File Nesting With DGN And DWG Files
          • Reference invisible in True Hidden Line
          • Reference level overrides do not display in sheet
          • Reference Name Cannot exceed 65 character limit MicroStation SE
          • Reference not displayed
          • Referenced DWG to DGN Coordinates Do Not Match
          • Referencing a 3D file into a 2D DGN
          • Rename full path data of reference
          • Restrict full path and relative path
          • Save as V8 or DWG merging reference levels that are off are being copied into the active file
          • Saved Views are working inconsistently with Dynamic Views
          • Set reference start in folder when attaching references
          • Setting which allows the ability to detach the parent (or carrier) reference while leaving the child ref in place
          • Specifying on/off setting for 'Treat Reference as element for manipulation' option for attached references through keyin
          • Text scales when attached as a reference
          • The Reference Preference Redux [CS]
          • Turn off rasters attached to reference files
          • Type 5 Reference Attachment
          • Unable to "Bring to Front"
          • Unable to detach some Reference Files in MicroStation 08.11.09.714. Message "You cannot Detach a model from a managed model. The operation is cancelled."
          • Undo not working for reference manipulation
          • Update modified reference files
          • Upgrading V7 View Dependent Reference Clip Boundaries To V8
          • Using Saved Views To Control Reference Display
          • V7 workmode, reference clip not retained after save
          • View orientation must match the boundary
          • What are the parameters for the keyin RF=
          • Whats New For Referencing
          • When Referencing 3D DWG Files to 2D Design Files, Elements Are Not Correctly Displayed
          • When referencing a DWG file to a master DWG file then closing the file the attachments are lost
          • Where is the Reference Logical name coming from when attaching References
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • Element's priority is different the priority of the level it's been placed on
        • +i.Models - MicroStation
        • +Raster - MicroStation
      • +Tips & Tricks
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Programming Wiki
    • +Visualization Wiki

     
     Questions about this article, topic, or product? Click here. 

    Recalling the Alert box after selecting "Do Not Display Again" when detaching all references

       
      Applies To 
       
      Product(s): MicroStation
      Version(s): 08.11.09.459
      Environment:  N\A
      Area:  Reference
      Subarea:  N\A
      Original Author: Andrew Bell, Bentley Technical Support Group
       

    Problem

    If you have selected “Do not display again” option in the alert dialog box that is displayed when detaching all reference is there any settings to display the alert dialog again?

     


    Solution

    The operation of this Alert Box has been tested and when the question is asked to “Do not display again” on the question for “Are you sure you want to detach ALL references?”.

    This setting is being stored in the UPF file related to the Workspace currently in use.

    The location of this UPF can be found by looking under:

    Workspace > About Workspace.

    This file is generally located by default under the folder:

    C:\Users\{Windows User ID}\AppData\Local\Bentley\MicroStation\8.11\.......\prefs\

    In order to resolve this issue:

    Exit from MicroStation, rename the relevant UPF file to .old

    When MicroStation reopened, this UPF file will be recreated with the default settings.

    See Also

    Product TechNotes and FAQs

    External Links

    Bentley Technical Support KnowledgeBase

    Bentley LEARN Server

    Comments or Corrections?

    Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    • Detach All
    • Reference
    • Share
    • History
    • More
    • Cancel
    • Andrew Bell Created by Bentley Colleague Andrew Bell
    • When: Mon, Dec 15 2014 10:51 PM
    • Dervalcanny Last revision by Dervalcanny
    • When: Tue, Feb 14 2017 6:20 AM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies