How to control the display of Reference during attachment.
Having attached References to a design, it is possible to toggle its display using the ' Display ' column setting in the References dialog.
< Image 1 to follow >
This can also be controlled during the attachment of the reference by toggling the ' Display ' icon on the 'Reference Attachment Properties' dialog during attachment.
<Image 2 to follow >
This configuration variable MS_REF_DEFAULTSETTINGS can also be used to set the default attachment settings including a setting for display. As with other variables these can be set at various levels affecting across the whole Organization, Workset or specifically for a user by modifying the appropriate configuration file, thus you may wish to consult your Site Administrator
To turn off the reference display set the variable
MS_REF_DEFAULTSETTINGS=levelControlDisplay=0
To turn on the reference display set the variable
MS_REF_DEFAULTSETTINGS=levelControlDisplay=1