Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
MicroStation
  • Product Communities
MicroStation
MicroStation Wiki DGN reference files in DWG work mode
    • Sign In

    • -MicroStation Wiki
      • +Learning Tips
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • +CONNECT Advisor - MicroStation
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • +Cells - MicroStation
        • +Change Tracking - MicroStation
        • +Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • -DWG - MicroStation
          • +Dimensions - DWG - MicroStation
          • +Edit - DWG - MicroStation
          • -General - DWG - MicroStation
            • 3D LineStrings are becoming planar when saved to DWG
            • AutoCAD PGP Files
            • Bentley CONNECT Edition - Autodesk RealDWG(TM) FAQ
            • Bentley V8i (SELECTseries 4) - Autodesk® RealDWG™ 2016 FAQ
            • Bentley V8i - Autodesk RealDWG(TM) FAQ
            • Cannot Copy/Paste Block from DWG to DGN
            • Cannot open Civil3D DWG fully in Microstation.
            • Civil 3D 2022 Object Enabler failure message when opening DWG files
            • Crash when opening any file - Windows error message
            • Creating a DWG Viewport using MicroStation
            • DGN - DWG Terminology
            • DGN reference files in DWG work mode
            • Disable autosave for DWG/DXF files
            • Display of some text in DWG viewports is not scaling correctly
            • DWG DXF Units Alert Box
            • DWGs created in AutoCAD Plant 3D cannot be displayed as Solid
            • Enable "RealDWG 2016" Update for DWG 2015/2016 format in SS3/SS4
            • Having saved my DGN to DWG why am I seeing duplicate Layers with ( Construction )
            • How to attach an ECW raster image to a DWG file within MicroStation?
            • How to download Autodesk REALDWG
            • How to get the DWG units alert box back
            • How to store DWG settings that will be used on a number of files.
            • In a DWG drawing with clipped reference
            • Line Styles And DWG Files
            • Line styles from reference appear as style Continuous
            • Microstation J support for AutoCAD 2004/2005
            • OHM symbol in blocks in DWG is not displayed correctly in V8i
            • Open views do not retain open after closing and reopening DWG
            • Option Save relative path in MS XM when working with DWG is not available
            • Place line string using ACAD line type
            • Prefix \ not working for DWG key-ins
            • RealDWG(TM) [TN]
            • Reference DXF into DXF capability
            • Referencing 3D DWG files to 2D design files elements are not correctly display
            • Supported AutoCAD Keyins
            • When in a DWG the sheet model does not show linestyles
            • Which MicroStation version supports which DWG/DXF version formats?
            • Will MicroStation support the .dwf format?
            • Would like to set up Workspace so DWG/DX...
          • +Open - DWG - MicroStation
          • +Raster - DWG - MicroStation
          • +Save - DWG - MicroStation
          • +Text - DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • +FAQ - MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MicroStation
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MicroStation
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • +Reference - MicroStation
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • +i.Models - MicroStation
        • +ProjectWise Integration
        • +Raster - MicroStation
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Printing and Plotting
    • +Programming Wiki
    • +Visualization Wiki
    • Window List Dialog for Missing Tool Dialog Boxes

     
     Questions about this article, topic, or product? Click here. 

    DGN reference files in DWG work mode

      Product(s): MicroStation
      Version(s): 08.11.09.869
      Environment: N\A
      Area: DWG
      Subarea: General

    Problem

    When in DWG work mode and having DGN files attached as reference, on opening the master file MicroStation comes with a message in the Message Centre, stating:

    DGN Reference "...\ReferenceDGN1.dgn" has been substituted for "ReferenceDGN1.dwg" The DWG reference file: "ReferenceDGN1.dgn" could not be found - "...\ReferenceDGN1.dgn" has been substituted for this attachment. This behaviour is expected when a DGN file is attached as a reference to a DWG file as it is not possible to store the DGN name in a DWG attachment.

    When working with a Document Management System, this could lead to all kind of problems.



    Solution

    There is no solution to solve this issue as it is a Works As Designed.

    However, it is possible to prevent attaching DGN files as reference while working in DWG work mode in MicroStation.

    This can be done by adding the capability statement

    _USTN_CAPABILITY_DWG > -CAPABILITY_REFERENCE_V8

    to ...\Bentley\MicroStation V8i (SELECTseries)\MicroStation\config\system\workmode.cfg

     

    Before making any changes to the configuration file, please make a copy to use as backup.



    See Also

    Other Language Sources

    Deutsch

     



    • GENERAL
    • MicroStation
    • 08.11.09.869
    • DWG
    • en
    • DWG work mode
    • SELECTsupport
    • Share
    • History
    • More
    • Cancel
    • Rene van den Brink Created by Rene van den Brink
    • When: Wed, Jul 4 2018 5:35 AM
    • A_F Last revision by Bentley Colleague A_F
    • When: Sat, Dec 29 2018 10:19 AM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies