Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
MicroStation
  • Product Communities
MicroStation
MicroStation Wiki CONNECT Advisor keeps turning on when starting MicroStation
    • Sign In

    • -MicroStation Wiki
      • +Learning Tips
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • -CONNECT Advisor - MicroStation
          • CONNECT Advisor error when MicroStation is started
          • CONNECT Advisor keeps turning on when starting MicroStation
          • CONNECT Advisor message: Unable to get Bentley CONNECT Advisor subscription, please try again.
          • CONNECT Advisor starts automatically when MicroStation is opened
          • Disable "CONNECT Advisor" for MicroStation startup
          • Dot Net Framework error when opening MicroStation V8i
          • Error when trying to access Bentley Connect Advisor YouTube content
          • Script error when running CONNECT Advisor
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • +Cells - MicroStation
        • +Change Tracking - MicroStation
        • +Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • +DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • +FAQ - MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MicroStation
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MicroStation
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • +Reference - MicroStation
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • +i.Models - MicroStation
        • +ProjectWise Integration
        • +Raster - MicroStation
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Printing and Plotting
    • +Programming Wiki
    • +Visualization Wiki

     
     Questions about this article, topic, or product? Click here. 

    CONNECT Advisor keeps turning on when starting MicroStation

    Product(s): MicroStation
    Version(s): 10.14.00.86
    Environment: N\A
    Area: CONNECT Advisor
    Subarea: N\A

    Problem Description

    CONNECT Advisor window pops up each time MicroStation is started, even though the automatic start is turned off in CONNECT Advisor settings.

    Steps to Resolve

    Perform the following steps:

    1.      Open Notepad as an Administrator.

    2.      Right click Notepad and “Run as Administrator”

    3.      Open file “C:\Program Files\Bentley\MicroStation CONNECT Edition\MicroStation\config\system\applicationload.cfg”

    4.      Search for “ConnectAdvisor”You will find this line “_USTN_FIRSTDGNFILE > ConnectAdvisor”

    5.      Add a Hash symbol “#_USTN_FIRSTDGNFILE > ConnectAdvisor” to the start of the line

    6.      File > Save

    See Also

    CONNECT Advisor overview

    Other language sources

      Original Author: Grzegorz Cwiek
    • MicroStation
    • 10.14.00.86
    • en
    • Other
    • Share
    • History
    • More
    • Cancel
    • Grzegorz Cwiek Created by Grzegorz Cwiek
    • When: Thu, Dec 31 2020 10:14 AM
    • Andrew Bell Last revision by Bentley Colleague Andrew Bell
    • When: Thu, Jan 21 2021 12:11 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies