Bentley MicroStation CONNECT Edition provides the following tools which can be used for basic auditing and correction purposes.
1. Standard Checker:The Standards Checker examines the open DGN file and compares the contents to the standards selected in the Standards Checker settings. To use the Standards Checker, you must first define a set of standards checks in a DGN library (DGNLib).
This tool can verify standards for the following content:
1. Level
2. Text Styles
3. Dimension Style
4. Element Template
More Information: Using the Standards Checker
2. Design File Cleanup: Used to identify duplicate elements, overlapping elements, and/or gaps between elements in the active design file.
Cleanup actions are performed in the Design File Cleanup dialog. More Information: Design File Cleanup
3. Compress Options: Compressing a DGN file reduces its size and clears the undo buffer. The COMPRESS OPTIONS <ON, OFF, RUN, TOGGLE> key-in is used to open the Compress Options dialog. More Information: Compressing Files
4. Level Audit: Levels in a file reside in an element referred to as a "Level Table". This includes the below features:a. Clear the duplicate level tables b. Orphaned elements Need proper key-ins documentation from Duplicate Level Tables - MicroStation Wiki - MicroStation - Bentley Communities