To which level are the elements in the master file moved from the reference file when using "Copy Pa


Product:

MicroStation
Version:CONNECT
Environment:N\A
Area:Levels
Subarea:General

Problem Description

To which level are the elements in the master file moved from the reference file when using "Copy Parallel" ?

Solution

1. Elements copied with "Copy Parallel" from the reference file are moved to the level in the master file, to the levels that correspond to each other according to the order of their creation ( where e.g. Level1, Level2, Level3 - levels in the reference file and Level1Master, Level2Master, Level3Master - levels in the master files). For example, if an element is in the level that was created second (Level2), then the element will be moved to Level2Master - as long as Level2 and Level2Master are the levels that were created second in order in their files. 

2. In case there is more levels in the reference file than in the master file, the elements from the level that has no "counterpart" in the master file are moved to the "Default" level.

3. It does not matter the number of reference files - elements behave according to points 1 i 2.

See also

Level Manager Dialog

Other language sources

Deutsch