<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Message Center - Saving Additional Information</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information</link><description>Bentley View, MicroStation, PowerDraft</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Message Center - Saving Additional Information</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information</link><pubDate>Fri, 25 Nov 2016 11:38:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2f46d020-d679-4346-92c6-f31af59949c8</guid><dc:creator>Marc Thomas</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information#comments</comments><description>Current Revision posted to MicroStation Wiki by Marc Thomas on 11/25/2016 11:38:51 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MicroStation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (08.11.09.459)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Logging&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;Capturing additional information from the Message center is often very helpful&amp;nbsp;during troubleshooting or on a more day-to-day basis&amp;nbsp;when reviewing the results of relatively compex operations&amp;nbsp;such as lengthy batch processes.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;Additional logging information can be obtained by increasing the size of the Message Centre log file.&lt;/p&gt;
&lt;p&gt;The default number of messages is 50, this will not be enough to capture all of the messages generated during some operations, for instance a batch compress operation.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;Open the message Center dialog, right-click:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7357.image001.png" border="0" /&gt;&lt;/p&gt;
&lt;p&gt;pick &amp;#39;Settings&amp;#39; then enter a larger number:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7080.image002.png" border="0" /&gt;&lt;/p&gt;
&lt;p&gt;These settings are saved in your user preferences.&lt;/p&gt;
&lt;p&gt;Admin Note: CAD/BIM Managers could deploy a preferred number of messages via a user preferences seed file.&lt;/p&gt;
&lt;h1&gt;Saving messages&lt;/h1&gt;
&lt;p&gt;Right-click and pick &amp;#39;Save Messages...&amp;#39; to save the messages and details to a text file.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;The default save location for this file is your project Out folder.&lt;/p&gt;
&lt;p&gt;The active selection is ignored when the messages are saved.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;a href="/other/old_site_member_blogs/peer_blogs/b/marc_thomass_blog/archive/2014/01/06/the-message-center-some-tips"&gt;The Message Center - Some Tips&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: MicroStation, batch processing, how to, Message Center, SELECTsupport&lt;/div&gt;
</description></item><item><title>Message Center - Saving Additional Information</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information/revision/6</link><pubDate>Fri, 25 Nov 2016 11:11:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2f46d020-d679-4346-92c6-f31af59949c8</guid><dc:creator>Marc Thomas</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information#comments</comments><description>Revision 6 posted to MicroStation Wiki by Marc Thomas on 11/25/2016 11:11:32 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MicroStation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (08.11.09.459)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Logging&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;Capturing additional information from the Message center is often very helpful&amp;nbsp;during troubleshooting or on a more day-to-day basis&amp;nbsp;when reviewing the results of relatively compex operations&amp;nbsp;such as lengthy batch processes.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;Additional logging information can be obtained by increasing the size of the Message Centre log file.&lt;/p&gt;
&lt;p&gt;The default number of messages is 50, this will not be enough to capture all of the messages generated during some operations, for instance a batch compress operation.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;Open the message Center dialog, right-click:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7357.image001.png" border="0" /&gt;&lt;/p&gt;
&lt;p&gt;pick &amp;#39;Settings&amp;#39; then enter a larger number:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7080.image002.png" border="0" /&gt;&lt;/p&gt;
&lt;p&gt;At the end of a batch process you will be able to right-click on the Message Center and pick &amp;#39;Save Messages&amp;hellip;&amp;#39;&amp;nbsp; to save the messages to a text file.&lt;/p&gt;
&lt;p&gt;These settings are saved in your user preferences.&lt;/p&gt;
&lt;p&gt;Admin Note: CAD/BIM Managers could deploy a preferred number of messages via a user preferences seed file.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;a href="/other/old_site_member_blogs/peer_blogs/b/marc_thomass_blog/archive/2014/01/06/the-message-center-some-tips"&gt;The Message Center - Some Tips&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: MicroStation, batch processing, how to, Message Center, SELECTsupport&lt;/div&gt;
</description></item><item><title>Message Center - Saving Additional Information</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information/revision/5</link><pubDate>Fri, 25 Nov 2016 11:09:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2f46d020-d679-4346-92c6-f31af59949c8</guid><dc:creator>Marc Thomas</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information#comments</comments><description>Revision 5 posted to MicroStation Wiki by Marc Thomas on 11/25/2016 11:09:05 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MicroStation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (08.11.09.459)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Logging&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;Capturing additional information from the Message center to assist when reviewing the results of operation such as lengthy batch processes.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;Additional logging information can be obtained by increasing the size of the Message Centre log file.&lt;/p&gt;
&lt;p&gt;The default number of messages is 50, this will not be enough to capture all of the messages generated during some operations, for instance a batch compress operation.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;Open the message Center dialog, right-click:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7357.image001.png" border="0" /&gt;&lt;/p&gt;
&lt;p&gt;pick &amp;#39;Settings&amp;#39; then enter a larger number:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7080.image002.png" border="0" /&gt;&lt;/p&gt;
&lt;p&gt;At the end of a batch process you will be able to right-click on the Message Center and pick &amp;#39;Save Messages&amp;hellip;&amp;#39;&amp;nbsp; to save the messages to a text file.&lt;/p&gt;
&lt;p&gt;These settings are saved in your user preferences.&lt;/p&gt;
&lt;p&gt;Admin Note: CAD Managers could deploy a preferred number of messages via a user preferences seed file.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;a href="/other/old_site_member_blogs/peer_blogs/b/marc_thomass_blog/archive/2014/01/06/the-message-center-some-tips"&gt;The Message Center - Some Tips&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: MicroStation, batch processing, how to, Message Center, SELECTsupport&lt;/div&gt;
</description></item><item><title>Message Center - Saving Additional Information</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information/revision/4</link><pubDate>Fri, 31 Jan 2014 22:13:20 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2f46d020-d679-4346-92c6-f31af59949c8</guid><dc:creator>Dan Koval</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information#comments</comments><description>Revision 4 posted to MicroStation Wiki by Dan Koval on 1/31/2014 10:13:20 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MicroStation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.459&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Logging&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Marc Thomas, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Capturing additional information from the Message center to assist when reviewing the results of operation such as lengthy batch processes.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;Additional logging information can be obtained by increasing the size of the Message Centre log file.&lt;/p&gt;
&lt;p&gt;The default number of messages is 50, this will not be enough to capture all of the messages generated during some operations, for instance a batch compress operation.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;Open the message Center dialog, right-click:&lt;/p&gt;
&lt;p&gt;&lt;img border="0" alt=" " src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7357.image001.png" /&gt;&lt;/p&gt;
&lt;p&gt;pick &amp;#39;Settings&amp;#39; then enter a larger number:&lt;/p&gt;
&lt;p&gt;&lt;img border="0" alt=" " src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7080.image002.png" /&gt;&lt;/p&gt;
&lt;p&gt;At the end of a batch process you will be able to right-click on the Message Center and pick &amp;#39;Save Messages&amp;hellip;&amp;#39;&amp;nbsp; to save the messages to a text file.&lt;/p&gt;
&lt;p&gt;These settings are saved in your user preferences.&lt;/p&gt;
&lt;p&gt;Admin Note: CAD Managers could deploy a preferred number of messages via a user preferences seed file.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: MicroStation, batch processing, how to, Message Center, SELECTsupport&lt;/div&gt;
</description></item><item><title>Message Center - Saving Additional Information</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information/revision/3</link><pubDate>Fri, 06 Sep 2013 14:40:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2f46d020-d679-4346-92c6-f31af59949c8</guid><dc:creator>Carl Myhill</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information#comments</comments><description>Revision 3 posted to MicroStation Wiki by Carl Myhill on 9/6/2013 2:40:51 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MicroStation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.459&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Logging&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Marc Thomas, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Capturing additional information from the Message center to assist when reviewing the results of operation such as lengthy batch processes.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;Additional logging information can be obtained by increasing the size of the Message Centre log file.&lt;/p&gt;
&lt;p&gt;The default number of messages is 50, this will not be enough to capture all of the messages generated during some operations, for instance a batch compress operation.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;Open the message Center dialog, right-click:&lt;/p&gt;
&lt;p&gt;&lt;img border="0" alt="" src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7357.image001.png" /&gt;&lt;/p&gt;
&lt;p&gt;pick &amp;#39;Settings&amp;#39; then enter a larger number:&lt;/p&gt;
&lt;p&gt;&lt;img border="0" alt="" src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7080.image002.png" /&gt;&lt;/p&gt;
&lt;p&gt;At the end of a batch process you will be able to right-click on the Message Center and pick &amp;#39;Save Messages&amp;hellip;&amp;#39;&amp;nbsp; to save the messages to a text file.&lt;/p&gt;
&lt;p&gt;These settings are saved in your user preferences.&lt;/p&gt;
&lt;p&gt;Admin Note: CAD Managers could deploy a preferred number of messages via a user preferences seed file.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: MicroStation, batch processing, how to, Message Center, SELECTsupport&lt;/div&gt;
</description></item><item><title>Message Center - Saving Additional Information</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information/revision/2</link><pubDate>Wed, 28 Aug 2013 18:23:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2f46d020-d679-4346-92c6-f31af59949c8</guid><dc:creator>Dan Koval</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information#comments</comments><description>Revision 2 posted to MicroStation Wiki by Dan Koval on 8/28/2013 6:23:47 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MicroStation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.459&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Logging&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Marc Thomas, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Capturing additional information from the Message center to assist when reviewing the results of operation such as lengthy batch processes.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;Additional logging information can be obtained by increasing the size of the Message Centre log file.&lt;/p&gt;
&lt;p&gt;The default number of messages is 50, this will not be enough to capture all of the messages generated during some operations, for instance a batch compress operation.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;Open the message Center dialog, right-click:&lt;/p&gt;
&lt;p&gt;&lt;img border="0" alt="" src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7357.image001.png" /&gt;&lt;/p&gt;
&lt;p&gt;pick &amp;#39;Settings&amp;#39; then enter a larger number:&lt;/p&gt;
&lt;p&gt;&lt;img border="0" alt="" src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7080.image002.png" /&gt;&lt;/p&gt;
&lt;p&gt;At the end of a batch process you will be able to right-click on the Message Center and pick &amp;#39;Save Messages&amp;hellip;&amp;#39;&amp;nbsp; to save the messages to a text file.&lt;/p&gt;
&lt;p&gt;These settings are saved in your user preferences.&lt;/p&gt;
&lt;p&gt;Admin Note: CAD Managers could deploy a preferred number of messages via a user preferences seed file.At the end of a batch process you will be able to right-click on the Message Center and pick &amp;#39;Save Messages&amp;hellip;&amp;#39;&amp;nbsp; to save the messages to a text file.&lt;br /&gt;These settings are saved in your user preferences.&lt;br /&gt;Admin Note: CAD Managers could deploy a preferred number of messages via a user preferences seed file.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: MicroStation, how to, SELECTsupport, Batch Processing, Message Center&lt;/div&gt;
</description></item><item><title>Message Center - Saving Additional Information</title><link>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information/revision/1</link><pubDate>Wed, 28 Aug 2013 16:00:13 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2f46d020-d679-4346-92c6-f31af59949c8</guid><dc:creator>Marc Thomas</dc:creator><comments>https://communities.bentley.com/products/microstation/w/microstation__wiki/8579/message-center-saving-additional-information#comments</comments><description>Revision 1 posted to MicroStation Wiki by Marc Thomas on 8/28/2013 4:00:13 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MicroStation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.459&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Logging&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Marc Thomas, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Capturing additional information from the Message center to assist when reviewing the results of operation such as lengthy batch processes.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;Additional logging information can be obtained by increasing the size of the Message Centre log file.&lt;/p&gt;
&lt;p&gt;The default number of messages is 50, this will not be enough to capture all of the messages generated during some operations, for instance a batch compress operation.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;Open the message Center dialog, right-click:&lt;/p&gt;
&lt;p&gt;&lt;img border="0" alt="" src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7357.image001.png" /&gt;&lt;/p&gt;
&lt;p&gt;pick &amp;#39;Settings&amp;#39; then enter a larger number:&lt;/p&gt;
&lt;p&gt;&lt;img border="0" alt="" src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-35/7080.image002.png" /&gt;&lt;/p&gt;
&lt;p&gt;At the end of a batch process you will be able to right-click on the Message Center and pick &amp;#39;Save Messages&amp;hellip;&amp;#39;&amp;nbsp; to save the messages to a text file.&lt;/p&gt;
&lt;p&gt;These settings are saved in your user preferences.&lt;/p&gt;
&lt;p&gt;Admin Note: CAD Managers could deploy a preferred number of messages via a user preferences seed file.At the end of a batch process you will be able to right-click on the Message Center and pick &amp;#39;Save Messages&amp;hellip;&amp;#39;&amp;nbsp; to save the messages to a text file.&lt;br /&gt;These settings are saved in your user preferences.&lt;br /&gt;Admin Note: CAD Managers could deploy a preferred number of messages via a user preferences seed file.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: MicroStation, how to, SELECTsupport, Batch Processing, Message Center&lt;/div&gt;
</description></item></channel></rss>