Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
MicroStation
  • Product Communities
MicroStation
MicroStation Wiki MicroStation and AutoCAD Object Enablers - OEs
    • Sign In

    • -MicroStation Wiki
      • +Learning Tips
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • +CONNECT Advisor - MicroStation
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • +Cells - MicroStation
        • +Change Tracking - MicroStation
        • +Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • -DWG - MicroStation
          • +Dimensions - DWG - MicroStation
          • +Edit - DWG - MicroStation
          • +General - DWG - MicroStation
          • -Open - DWG - MicroStation
            • "Unable to locate and open seed file required to open this file."
            • All dwg files open with red background color
            • AutoCAD 3D Objects are not displaying with Object Enablers installed.
            • Can't open DWG 2010 in AutoCAD 2013 created in MicroStation V8i
            • Cannot Open DWG file in CONNECT Edition
            • Cannot open DWG settings dialog
            • Coordinates of a dwg are correct in MicroStation, but not in AutoCAD
            • DBX CAS 4 Error happens whith DWG files
            • Dimension style in ACAD will take on bylevel weight for dimension text
            • Disable creation of DWG backup files
            • DWG block attributes as Tags Or Item Types
            • DWG color table is all black
            • DWG file is opening with the wrong units
            • DWG must be shifted to fit design plane
            • Error "dbobji.cpp@6858" when opening a DWG file
            • Excessive group definitions--when opening
            • File format and version of AutoCAD files
            • Getting "unable to open DWG" message
            • How to control the Viewport Locked setting available in AutoCAD
            • How to Setup DWG Options settings for multiple users across network.
            • Inability to open DWG files and to save a file as a dwg
            • Incompatible version of AEC objects!
            • Line types in DWG file are not showing the point symbols.
            • Locked Elements in a DWG file
            • MicroStation and AutoCAD Object Enablers - OEs
            • On opening DWG file some/most elements are locked
            • Open DWG files with set Global Origin
            • Opening And Saving DWG Files In MicroStation V8
            • Opening DWG Files
            • Tag appears incorrect in DWG
            • Unable to locate and open seed file required
            • Using The DWG Work Mode In MicroStation V8 [CS]
            • When a DWG is renamed to anything other than DWG, it cannot be opened
            • When importing a DWG, some levels disappear and its elements are placed on the "Default" level
            • Working With DWG Reference Files [CS]
          • +Raster - DWG - MicroStation
          • +Save - DWG - MicroStation
          • +Text - DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • +FAQ - MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MicroStation
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MicroStation
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • +Reference - MicroStation
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • +i.Models - MicroStation
        • +ProjectWise Integration
        • +Raster - MicroStation
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Programming Wiki
    • +Visualization Wiki

     
     Questions about this article, topic, or product? Click here. 

    MicroStation and AutoCAD Object Enablers - OEs

      Product: MicroStation
      Version: V8i and CONNECT
      Environment: N\A
      Area: DWG
      Subarea: Open

    Overview

    When opening a DWG file in MicroStation, a message is displayed in the statusbar:
    One or more Object Enablers is missing

    Background

    In the AutoCAD file format a number of standard object/element definitions are available, such as lines, texts, etc.
    Autodesk allows application developers to create additional object definitions to better suit their application (you may think of them as "smart objects").  An application that creates these objects may also provide a so called Object Enabler that runs on a RealDWG host program different than the application itself.
    Such additional objects are called Custom Objects, when their object enablers are present, or Proxy Objects when their object enablers are missing.

    In order to display custom objects the related application Object Enabler needs to have been installed on a RealDWG host program such as AutoCAD or MicroStation.

    Custom or Proxy objects on MicroStation

    Following Bentley's agreement with Autodesk, RealDWG libaries were available for use in MicroStation. Thus versions of MicroStation V8i Selectseries 1 or later, DWG files are opened with Autodesk's RealDWG and custom objects with their object enablers are better displayed.  Therefore, it is recommended that you get an object enabler for DWG files that contain custom objects.  If you do not have these object enablers, you will see the message: “One or more Object Enablers is missing” in the status bar after you opened such a DWG file.  In such a case, as described above, these objects become proxies, which may or may not be displayed correctly depending on:

    (a) if the DWG file as last saved with system variable PROXYGRAPHICS on AutoCAD,
    (b) if the object enabler is designed to save the graphics in response to this system variable, and
    (c) if the information/geometry saved in the proxies is as good as you expect (wireframe or mesh, for example). 

    If the answer to all three questions is positive, then your proxies may display correctly.  Otherwise you may see problems with them.

    Which Object Enabler to download/install

    Object enablers are available for 32bit and 64bit operating systems. 64bit object enablers versions cannot be used in a 32bit environment. However, a good number of 32bit object enablers are suitable to be used on a Windows 64bit operating system.

    Object enablers require an equivalent 32bit or 64bit CAD application. MicroStation V8i Select Series is a 32bit application and MicroStation CONNECT Edition is a 64bit application. You need to install the appropriate object enabler based on the corresponding version of MicroStation being used.

    Object enablers are also AutoCAD version/year specific. For example: if you are running AutoCAD 2019 or MicroStation with 2019 RealDWG you need to install the 2019 Object Enablers. Installing a different version/year object enabler will not work.

    Example: if you are running MicroStation CONNECT Edition with 2019 RealDWG you would need to install the 2019 Object Enabler 64bit version to work with MicroStation.

    To find the version of RealDWG your MicroStation is using go to: File/Save As/set save as type to DWG, select Options box, General Tab, click on DWG versions, look at the latest version listed in that box. That is the version/year of RealDWG your MicroStation is using. This would be the corresponding object enabler needed to work with your version of MicroStation.

      

    Notes

    • If a DWG file has to be edited later on with the application with which it was built, be sure to make a backup copy of the original file first before opening it in MicroStation. Also, before opening a file that includes custom objects, make sure that exactly the same DWG file format is set.
      For example consider that a file has been created based on the AutoCAD version 2009 then you define MS_REALDWG_VERSION = 2009 before opening the file.
      If you would open such a file having the AutoCAD 2010 version active, the data in the file will be upgraded to the 2010 format the custom objects however will not.
      The result is that the original application will not be able to edit the file anymore.
    • Starting with Bentley V8i (SELECTseries 1) - Autodesk® RealDWG™ 2010 includes the following object enablers, which can be used with products that have then enabled:
      • AutoCAD Architecture and AutoCAD MEP 2010 Object Enabler
      • AutoPLANT V8i (SELECTseries 1) Object Enabler
      • ProSteel V8i for AutoCAD 2010 Object Enabler
    • True object enablers are developed with ObjectDBX. If an object enabler has the file extension .DBX, it should be loadable using MicroStation V8i SELECTseries 1 or 2 with RealDWG installed. If the object enabler has a file extension of .ARX, it was not developed using ObjectDBX and most likely cannot be loaded using MicroStation V8i SELECTseries 1 or 2. Bentley Systems Inc. cannot do much here as for a fix we depend on Autodesk or the related Application vendor who created the enabler.
      A known enabler that does not conform to Autodesk's own definition of Object Enablers is:Autodesk Raster Design 2010  (TR# 299032). 
    • Upon installation of an Object Enabler, a window may pop-up asking for which application the enabler should be activated, in such a case, the installed platform product should be selected (MicroStation V8i Selectseries 1 or up).  However, not all object enablers offer such an option (CADDuct serves as such an example).

    See also

    RealDWG(TM) [TN]

    Download - Object Enablers

    Other language sources

      Original Author: Bentley Technical Support Group
    • MicroStation V8i
    • SELECTservices
    • AutoCad
    • TechNote
    • open
    • DWG
    • Object Enablers
    • MicroStation Connect Edition
    • Share
    • History
    • More
    • Cancel
    • Dan Koval Created by Bentley Colleague Dan Koval
    • When: Thu, Sep 5 2013 4:42 PM
    • Todd Moser Last revision by Bentley Colleague Todd Moser
    • When: Fri, May 29 2020 10:22 AM
    • Revisions: 8
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies