Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
MicroStation
  • Product Communities
MicroStation
MicroStation Wiki "Unable to locate and open seed file required to open this file."
    • Sign In

    • -MicroStation Wiki
      • +Learning Tips
      • -MicroStation
        • +3D Printing - MicroStation
        • +Animation - MicroStation
        • +Archive / Backup - MicroStation
        • +Base Geometry - MicroStation
        • +Batch Processing - MicroStation
        • +CONNECT Advisor - MicroStation
        • CONNECT Integration - MicroStation
        • +CONNECTION Client
        • +Cells - MicroStation
        • +Change Tracking - MicroStation
        • +Configuration - MicroStation
        • +Coordinate Systems - MicroStation
        • +Curves - MicroStation
        • +Custom Linestyles - MicroStation
        • +DGN - MicroStation
        • -DWG - MicroStation
          • +Dimensions - DWG - MicroStation
          • +Edit - DWG - MicroStation
          • +General - DWG - MicroStation
          • -Open - DWG - MicroStation
            • "Unable to locate and open seed file required to open this file."
            • All dwg files open with red background color
            • AutoCAD 3D Objects are not displaying with Object Enablers installed.
            • Can't open DWG 2010 in AutoCAD 2013 created in MicroStation V8i
            • Cannot Open DWG file in CONNECT Edition
            • Cannot open DWG settings dialog
            • Coordinates of a dwg are correct in MicroStation, but not in AutoCAD
            • DBX CAS 4 Error happens whith DWG files
            • Dimension style in ACAD will take on bylevel weight for dimension text
            • Disable creation of DWG backup files
            • DWG block attributes as Tags Or Item Types
            • DWG color table is all black
            • DWG file is opening with the wrong units
            • DWG must be shifted to fit design plane
            • Error "dbobji.cpp@6858" when opening a DWG file
            • Excessive group definitions--when opening
            • File format and version of AutoCAD files
            • Getting "unable to open DWG" message
            • How to control the Viewport Locked setting available in AutoCAD
            • How to Setup DWG Options settings for multiple users across network.
            • Inability to open DWG files and to save a file as a dwg
            • Incompatible version of AEC objects!
            • Line types in DWG file are not showing the point symbols.
            • Locked Elements in a DWG file
            • MicroStation and AutoCAD Object Enablers - OEs
            • On opening DWG file some/most elements are locked
            • Open DWG files with set Global Origin
            • Opening And Saving DWG Files In MicroStation V8
            • Opening DWG Files
            • Tag appears incorrect in DWG
            • Unable to locate and open seed file required
            • Using The DWG Work Mode In MicroStation V8 [CS]
            • When a DWG is renamed to anything other than DWG, it cannot be opened
            • When importing a DWG, some levels disappear and its elements are placed on the "Default" level
            • Working With DWG Reference Files [CS]
          • +Raster - DWG - MicroStation
          • +Save - DWG - MicroStation
          • +Text - DWG - MicroStation
        • +Database - MicroStation
        • +Detailing Symbols - MicroStation
        • +Dimensions - MicroStation
        • +Documentation & Help - MicroStation
        • +Drawing Aids - MicroStation
        • +Exception - MicroStation
        • +FAQ - MicroStation
        • +Feature Based Solids Modeling - MicroStation
        • +File Access - MicroStation
        • +GUI - MicroStation
        • +General - MicroStation
        • +Graphics Display - MicroStation
        • +Groups - MicroStation
        • +Hardware / Input Devices - MicroStation
        • +Import/Export - MicroStation
        • +Installation - MicroStation
        • +Interchange - MicroStation
        • +Interference - MicroStation
        • +Internationalization - MicroStation
        • +Levels - MicroStation
        • +Licensing - MicroStation
        • +Manipulation - MicroStation
        • +Markup / Redline - MicroStation
        • +Measure - MicroStation
        • +Mesh - MicroStation
        • +Models - MicroStation
        • +Multi-Lines - MicroStation
        • +OLE - MicroStation
        • +Other - MicroStation
        • +Parametrics - MicroStation
        • +Patterning - MicroStation
        • +Point Cloud - MicroStation
        • +Printing - MicroStation
        • +Programming - MicroStation
        • +Project Navigation - MicroStation
        • +Properties - MicroStation
        • +RSS Feeds - MicroStation
        • +Reference - MicroStation
        • +Security - MicroStation
        • +Selection - MicroStation
        • +Settings - MicroStation
        • +Sheet Composition - MicroStation
        • +Solids - MicroStation
        • +Standards - MicroStation
        • +Surfaces - MicroStation
        • +Tables - MicroStation
        • +Text - MicroStation
        • +UI Customization - MicroStation
        • +Units - MicroStation
        • +View - MicroStation
        • +Visualization - MicroStation
        • Welcome Page - MicroStation
        • +Accreditation - MicroStation
        • +i.Models - MicroStation
        • +ProjectWise Integration
        • +Raster - MicroStation
    • +Administration Wiki
    • +Annotations Wiki
    • +Bentley View Wiki
    • +MicroStation PowerDraft
    • +Programming Wiki
    • +Visualization Wiki

     
     Questions about this article, topic, or product? Click here. 

    "Unable to locate and open seed file required to open this file."

      Product: MicroStation
      Version: 08.11.09.459
      Environment: N\A
      Area: DWG
      Subarea: Open

    Error or Warning Message

    Unable to locate and open seed file required to open this file. Check the MS_TRANSEED configuration variable."

    Explanation

    Attempting to open DWG / DXF or a master file a referenced DWG / DXF file.

    How to Avoid

    Option #1- Define the MS_TRANSEED Variable

    1. Go to Workspace > Configuration > Seed Files category
    2. Look up "DWG Seed File"
    3. Click "Select"
    4. Browse to the location of a valid transeed file
    5. Save configuration


    Option #2 - Reset settings

    1. Go to path defined by MS_DWGDATA for example by following key in: $ % explorer $(MS_DWGDATA)
    2. Close MicroStation
    3. Delete dwgsettings.rsc file

    This file will be regenerated the next time a file is converted to DWG or DWG file is open and "Options" button is invoked and making a change to the settings.

    Option #3 - Selecting translation seed file

    1. From MicroStation Open dialog select DWG / DXF file
    2. Click on the Options button
    3. Go to the Basic section
    4. Go to the "DGN Seed File:"
    5. In Value column select the current value and then browse to location of desired seed file
    6. Choose the file and click on the "Open" button

    This will override the path set in MS_TRANSEED variable.

    See Also:

    http://communities.bentley.com/products/microstation/w/microstation__wiki/15370.unable-to-open-seed-file-seed-dwg


    Other Language Sources

    Deutsch

      Original Author: Reginald Wallace
    • MicroStation
    • open
    • ms_transeed
    • error message
    • DWG
    • SELECTsupport
    • Share
    • History
    • More
    • Cancel
    • Reginald Wallace Created by Bentley Colleague Reginald Wallace
    • When: Wed, Oct 9 2013 10:15 AM
    • Andrew Bell Last revision by Bentley Colleague Andrew Bell
    • When: Wed, Jun 12 2019 9:20 PM
    • Revisions: 8
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies