When we choose the following code check options:
a. Member code check option: NC - NORSOK STANDARDS 2013 N-004 WITH EUROCODE 3:2005
b. Joint code check in joint can input file: NORS - NORSOK STANDARD 2004 N-004
What material resistance factors are considered with these two options?
These are the default values. You can change them in the analysis option using the CODE EC card.
Design Code - (EC3:2005)
Design Code - NORSOK N-004 2013