Product(s): | SACS |
Version(s): | All |
Area: | Precede |
Here are steps to be taken to change the position of calculated COG:
Model 1
1. After completing the model & loads, run a static analysis to check the COG of the structure.
2. In the list file, we can see the COG is (-0.29, 0.59).
Model 2
1. Note the coordinate of new COG from the origin. For this example, we will change the coordinate to (-1,1)
2. Delete all loads and add two new skid loadings.
(i) COG as load condition 1
(ii) POINT1 the opposite direction of COG as load combination 2.
3. Verify the load application in the listing file:
Model 3
1. In the original model, reactions at joints are applied to change the COG to a new location.
2. Run the analysis, and you'll get to see the COG changed to a new location.