20. Time History Results on symmetric model does not match when using AutoPIPE, why?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Report Date Logged & Current Version Feb 2020 12.02.00.14 Problem: Per the given symmetric model (attached, original and one I created from scratch): …
over 1 year ago
AutoPIPE
AutoPIPE Wiki
21. Calculate SAM and Expansion stress values independently, and then add these two stress values together in a single combination using AutoPIPE
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Date Logged & Current Version Jan 2020 12.02.00.14 Problem: Calculate SAM stress values and Expansion stress values independently, and then add these two…
over 3 years ago
AutoPIPE
AutoPIPE Wiki
20. How are the moment results for the selected Combination Method (ex. SRSS, ABS, etc..) calculated in AutoPIPE?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Date Logged & Current Version Nov 2019 12.02.00.14 Problem: How are the moments in the Code Compliance report calculated based on different combination…
over 3 years ago
AutoPIPE
AutoPIPE Wiki
08. What is more important, AutoPIPE's results for Operating Conditions (ex. GrT1P1, GrT2P2, ...etc. ) or the individual load cases (ex. P2, T1, T2, Gr, P1...) results?
Mike Dattilio
Answer: The user would be advised to only look at the results for Operating Conditions (ex. GrT1P1, GrT2P2, ...etc). Would suggest that user turn off all non-operating conditions. Example: Give the following Analysis sets: This would produce…
over 4 years ago
AutoPIPE
AutoPIPE Wiki
03. Why no Max Range combination was displayed for HDPE piping?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Results Date Logged & Current Version April 2019 12.00.00.14 Problem: Why is there no Max Range code combination for HDPE piping with the "Include Max Range…
over 4 years ago
AutoPIPE
AutoPIPE Wiki
02. What value should be entered into the "No. of thermal ranges" setting in AutoPIPE?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Settings Original Author: Bentley Technical Support Group Date Logged & Current Version Jan. 2017 10.01.00.09 Problem: What value should be entered…
over 5 years ago
AutoPIPE
AutoPIPE Wiki
08. The AutoPIPE code combination value of "Max Range {TR]" does not match the indicated combination value or any of the other Expansion combination values, why?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version July 2015 09.06.02.06 Problem: The AutoPIPE…
over 5 years ago
AutoPIPE
AutoPIPE Wiki
05. Why does the floating dialog not show all the load cases analyzed in an AutoPIPE model?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Results Original Author: Bentley Technical Support Group Date Logged & Current Version July. 2017 11.00.00.22 Problem: …
over 3 years ago
AutoPIPE
AutoPIPE Wiki
04. How to get stress results for gravity load-case only in AutoPIPE?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Environment: N/A Area: Reports Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015…
over 6 years ago
AutoPIPE
AutoPIPE Wiki
12. How to limit AutoPIPE's Output results to selected combinations?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i, CONNECT; Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version May. 2016 10.01.00.09 …
over 4 years ago
AutoPIPE
AutoPIPE Wiki