    • 17. Why are results for a combination subtracting dynamic load cases (ex. GRT1P1 +U1 -S1 -R1) higher than when adding the same dynamic load cases (ex. GRT1P1 +U1 +S1 +R1) in AutoPIPE?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Report Date Logged & Current Version April. 2018 11.03.00.08 Problem: Why are results for a combination subtracting dynamic load cases (ex. GRT1P1 +U1 …
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • W831-14: Maximum number of combinations limit is reached. message appeared in AutoPIPE

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Warning Message Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10 …
      • over 2 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 02. What value should be entered into the "No. of thermal ranges" setting in AutoPIPE?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Settings Original Author: Bentley Technical Support Group Date Logged & Current Version Jan. 2017 10.01.00.09 Problem: What value should be entered…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 14. Why are my Code / Non-code combinations not being printed in the output report or results grids when using AutoPIPE?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Reports Original Author: Bentley Technical Support Group Date Logged & Current Version Dec. 2016 10.01.00.09 Problem: Why are my actual load cases…
      • over 4 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 07. How to add combinations to the Forces and Moment's output report in AutoPIPE?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Combination Original Author: Bentley Technical Support Group Date Logged & Current Version Nov. 2016 10.01.00.09 Problem…
      • over 4 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 06. How to automatically find the MAX load case from a group of load cases in an AutoPIPE model

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE, Version(s): All Area: Combinations Original Author: Bentley Technical Support Group Problem: In order to evaluate the total load from operating conditions and…
      • over 4 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • General questions not covered by AutoPIPE's Code / Non-Code combination WIKI pages

      Mike Dattilio
      Mike Dattilio
      1. Default Code and Non-Code Combinations in an AutoPIPE model 2. User Combinations as a Template for the Next Model User code or non-code combinations created in the program can be used as a template for other models with the same analyzed load cases…
      • 10 months ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 16. How does the program determine the Young's modulus value used when calculating the bending stress due to the combined moments from multiple load cases in a User defined combination in AutoPIPE?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Combinations Original Author: Bentley Technical Support Group Date Logged & Current Version Nov. 2016 10.01.00.09 Problem…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • Default Code and Non-Code Combinations in an AutoPIPE model

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): All Area: Settings Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2016 10.00.00.10 Problem: How…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 07. AutoPIPE Results grids / Output report, Code Stresses are completely blank, why and how to avoid?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): All Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10 Problem: The Results…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 10. How to add the effects of movements from sources other than thermal loading in his AutoPIPE's displacement combinations?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): All Area: Combination Original Author: Bentley Technical Support Group Date Logged & Current Version Nov. 2015 10.00.00.10 Suggested procedure…
      • over 4 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • "Code Comb" tab Questions

      Mike Dattilio
      Mike Dattilio
      The "Code Compliance" grid displays the combination set defined for piping code compliance (both the default combinations and user-defined sets). Any default code combination may be modified, deleted or reset and any new user combination created and modified…
      • 8 months ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 08. The AutoPIPE code combination value of "Max Range {TR]" does not match the indicated combination value or any of the other Expansion combination values, why?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): All Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version July 2015 09.06.02.06 Problem: The AutoPIPE…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 03. Non-Linear Analysis - Wind Load review in AutoPIPE

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Combination Original Author: Bentley Technical Support Group Let us consider this simple example…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 08. How are "Sustained + Earthquake + Seismic Displacements" combined in an AutoPIPE model?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Combination Date Logged & Current Version April. 2018 11.03.00.08 Problem: How are "Sustained + Earthquake + Seismic Displacements" combined in an AutoPIPE…
      • 6 months ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 09. Which category should be chosen to accommodate DNV-OS-F101 standard. section 5 "DESIGN – LIMIT STATE CRITERIA", D 600 Local buckling combined loading criteria in AutoPIPE?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Calculations Date Logged & Current Version April. 2014 09.06.00.15 Problem: Which category should be chosen to accommodate DNV-OS-F101 standard. section…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • Code Combination for reporting Longitudinal Stress

      Mark Upston
      Mark Upston
      "Matthew Kuriger" wrote: Hi I am analysing piping systems to DNV-OS-F101 2005. One of the code combination checks (using Allowable Stress Design) is reporting longitudinal stress against allowable stress. I have a simple piping system (see attached…
      • Answered
      • over 14 years ago
      • AutoPIPE
      • AutoPIPE Forum
    • Code Combinations

      Mark Upston
      Mark Upston
      Bolarinwa wrote, Why does the Max Range, SUS+WIND gives different values when ran using "Initial case for Occ. loads: GR,OP1 or OP2" options??
      • over 14 years ago
      • AutoPIPE
      • AutoPIPE Forum
    • 02. AutoPIPE vs CAESAR load combinations

      Mike Dattilio
      Mike Dattilio
      Comments, Questions, and Answers Items #1: In the end both AutoPIPE and CAESAR perform the same task of providing the user with stress analysis results based on load cases applied to a geometric model of a piping system. However, there is a fundamental…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • W774-47 One or more combinations are set to none warning message in AutoPIPE

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Analysis Original Author: Bentley Technical Support Group Problem: The…
      • over 2 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • A-02. Warning - "Missing user combination File... *.UCB" message displayed when importing a model into AutoPIPE Nozzle

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Nozzle Version(s): V8i Environment: N/A Area: Import Original Author: Bentley Technical Support Group Date Logged & Current Version June…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • W214-1: The combination data file (*.CMB) you are about to open was created in a different version... message was seen in AutoPIPE, why?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Original Author: Bentley Technical Support Group Date Logged & Current Version Jan. 2017 10.01.00.09 Problem: The following…
      • over 2 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 16. Why is model over stress due to Hydrotest load-case when using AutoPIPE?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Report Date Logged & Current Version Sept. 2017 11.01.00.23 Problem: When including Temperature (T3 = 400 deg C) in the Hydrotest load combination, the…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 18. Why is there no sustain Code combination with Gravity, Pressure, and Temperature in AutoPIPE?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Combination Original Author: Bentley Technical Support Group Date Logged & Current Version Aug. 2017 11.01.00.17 Problem…
      • over 6 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 03. When creating a new AutoPIPE User defined combination on the Code Comb tab, is the order of the load cases / combinations of any consequence?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL Area: combination Original Author: Bentley Technical Support Group Date Logged & Current Version May 2015 09.06.02.06 Problem: When…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • View related content from anywhere
    • More
    • Cancel
    <>
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies