29. AutoPIPE Vessel (43.01.01.011) don't have option for Earthquake analysis as per Design Spectrum method in EN 1998-1 (3.2.2.5).
Tanaji Gaikwad
Answer: Earthquake load design as per EN 1998-1 (3.2.2.5) is not currently available. A feature has been created which will be implemented as soon as possible.
4 months ago
AutoPIPE
AutoPIPE Wiki
01. Is the correct Soil Factor per EN1998-1 being used in AutoPIPE vessel?
JamieP
Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Modeling Date Logged & Current Version March 2018 40.06.00.07 Problem: Is the correct Soil Factor per EN1998-1 being used? Solution: There was…