Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
AutoPIPE
Sign In
All tags
outside
-2
-3
-30
-38
-55
allowable
ambient
AutoPIPE
code
diameter
Expansion
Fcr
Library
message
Note
Range
Soil
Temperature
W2164
W726
W727
W762
warning
W727-3: Temperature is outside the range specified by the code for allowable warning message in AutoPIPE
Mike Dattilio
Applies To Product(s): AutoPIPE, Version(s): all Area: Warning Message Original Author: Bentley Technical Support Group Problem The following appears when running entering data into the AutoPIPE…
over 2 years ago
AutoPIPE
AutoPIPE Wiki
W727-2: Temperature is outside the range specified the code for Expansion for AutoPIPE
Mike Dattilio
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Area: warning Original Author: Bentley Technical Support Group Problem: Preparing input for code NB class-1 multi-operating temperature…
over 2 years ago
AutoPIPE
AutoPIPE Wiki
W726-38: Allowable at ambient is outside of temperature range at point XXX for material YYYY warning message in AutoPIPE
Mike Dattilio
Applies To Product(s): AutoPIPE, Version(s): V8i Environment: N/A Area: Warning, Library Original Author: Bentley Technical Support Group Problem: While…
over 2 years ago
AutoPIPE
AutoPIPE Wiki
W2164-30: Outside diameter does not match with soil properties at following point(s) warning message occurred in AutoPIPE, why?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Original Author: Bentley Technical Support Group Date Logged & Current Version June. 2017 11.00.00.22 Problem: The following…
over 2 years ago
AutoPIPE
AutoPIPE Wiki
W726-55: Creep data for (xx) is above temperature range. Zero allowable used at point (xxx) for material (yyyy)
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i, CONNECT; Area: Warning Original Author: Bentley Technical Support Group Date Logged & Current Version Apr. 2016 10.01…
over 2 years ago
AutoPIPE
AutoPIPE Wiki
View related content from anywhere