• Example 02 - Model piping connected to end of a vessel / tank supported by legs in AutoPIPE

    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Modeling Date Logged & Current Version Aug 2023 23.00.00.230 Example: Model piping arrangement: There are multiple options to model connected piping…
  • Inserting nozzles, flanges and leg supports in autopipe vessel tank

    Hi all, How to insert flanges, leg support, nozzles in autopipe vessel tank, please help me with the process .
  • 01. API 650 Live load - How to introduce a live load on a roof that is not Snow. It only considers 1000N/m2 as default?

    Answer: Only snow loading has been provided for loads on the roof. The way to consider an other load is to input an equivalent snow load.
  • AutoPIPE Vessel for CONNECT Edition

    to Eastern Time (US & Canada)
    Virtual
    Join Senior Piping Application Engineer, Jessica Alegre, in this Live Virtual AutoPIPE Vessel Training! Register on the LEARNserver or through the Bentley Events page. AutoPIPE Vessel Courses must be registered for individually and include: Introduction...
  • 10. How to model a vertical vessel held in place by 4 supports in AutoPIPE?

    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Modeling Original Author: Bentley Technical Support Group Date Logged & Current Version Oct. 2016 10.01.00.09 Problem: …
  • 12. How to model piping connected the end of a tank / vessel in AutoPIPE?

    Applies To Product(s): AutoPIPE Version(s): All Area: Modeling Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2016 10.00.00.10 Problem: There…
  • 03b. Modeling Vessel / Nozzles in AutoPIPE

    The following section will contain questions and answers pertaining to modeling vessels and/or nozzles in AutoPIPE. ATTENTION: Please see the following AutoPIPE help section: Help > Contents> Contents Tab> Modeling Approaches> Modeling Approaches…
  • Nozzle modeling: W41-27 error

    I am trying to model a 20" STD connection to a tank of 40 m diameter at 1 m above ground level, filled to 13 m high. Naturally I use the API 650 flexibility method (I assume it's using the Appendix P calculations, meant for tanks above 36 m in diameter…
  • Tanks