You are currently reviewing an older revision of this page.
The following occurs when using AutoPIPE:
forrtl: severe (24): end-of-file during read, unit 11, file c:\progra files\bentley\autopipe xm \autoplan.cnf
OR
How to resolve ?
The problem is that something has corrupted the Autoplan.CNF file on your computer. Use one of the following solutions:
Solution #1: Using AutoPIPE v 10.01.xx.xx and HIGHER, with these versions, the AutoPlan.CNF file is a temporary file located in the user's profile. remove AutoPLAN.CNF from user's configuration (file path found on the dialog shown above):
C:\Users \---user name--- \AppData \Roaming \Bentley \AutoPIPE CONNECT
Restarting AutoPIPE will copy the AutoPLANT.CNF file from the program's directory back into the user's profile directory thus fixing the problem.
Solution #2: Close AutoPIPE, copy a Autoplan.CNF file from another computer that has the exact same version installed. Paste the copied file on the system having the issue in the same location overwriting the original file, and restart AutoPIPE.
Solution #3: Close AutoPIPE, completely remove AutoPIPE from the system and reinstall the program.
Visual Fortran run-time error messages