AutoPIPE Wiki Forrtl: severe (59): List-directed I/O syntax error , FOR$IOS_LISIO_SYN 2
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • -Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
          • "1 Interrupted Action" messages displayed while coping AutoPIPE file, why?
          • +"Alert" Messages displayed in AutoPIPE
          • +"AutoPIPE Licensing" Messages displayed in AutoPIPE
          • +"Autopipe.exe" Messages displayed in AutoPIPE
          • +"Beam Section" Messages displayed in AutoPIPE
          • +"Bentley AutoPIPE" Messages displayed in AutoPIPE
          • +"Bentley Systems, Inc" Messages displayed in AutoPIPE
          • "Bentley.lictransmit for Windows has stopped working" message appears when using AutoPIPE program, why?
          • +"Blank" Messages displayed in AutoPIPE
          • +"Bolts*" Messages displayed in AutoPIPE
          • +"Confirm" Messages displayed in AutoPIPE
          • +"Error" messages displayed in AutoPIPE
          • +"Flange*" Messages displayed in AutoPIPE
          • +"Incorrect Data" messages displayed in AutoPIPE
          • -"Intel(r) Visual Fortran run-time error" messages displayed in AutoPIPE
            • forrtl: info (58): format syntax error at or near... message appears when using AutoPIPE
            • Forrtl: severe (104): incorrect POSITION= specifier value connected file, unit 101, file message in AutoPIPE
            • forrtl: severe (24): end-of-file during read, unit -5, file Internal List-Directed Read error appears when using AutoPIPE
            • Forrtl: severe (24): end-of-file during read, unit -95, file Internal List-Directed Read error appears when using AutoPIPE
            • forrtl: severe (24): end-of-file during read, unit 11, file c:\progra files\bentley\autopipe xm\autoplan.cnf
            • forrtl: severe (257): formatted I/O to unit open for unformatted transfers
            • forrtl: severe (29): file not found, unit 46, file error appears when using AutoPIPE
            • forrtl: severe (29): file not found, unit 6, file ....error appears when using AutoPIPE
            • forrtl: severe (30): open failure, unit 6, file....OUT
            • Forrtl: severe (38): error during write, unit 0, file CONOUT$
            • Forrtl: severe (38): error during write, unit 11, file
            • Forrtl: severe (38): error during write, unit 6, file CONOUT$
            • forrtl: severe (43); file name specification error, unit 6, file... message appears when starting AutoPIPE
            • forrtl: severe (47): write to READONLY file, unit 72,...
            • Forrtl: severe (59): List-directed I/O syntax error , FOR$IOS_LISIO_SYN 2
            • Forrtl: severe (64) - Input conversion error
            • Forrtl: severe (9): permission to access file denied, unit 121
            • forrtl: severe (9); permission to access file denied, unit 10, file... message appears when starting AutoPIPE
          • +"Invalid Format" messages displayed in AutoPIPE
          • +"License Management Tool" Messages displayed in AutoPIPE
          • "Message from SofTrack" Messages displayed in AutoPIPE
          • +"Microsoft .NET Framework".. messages displayed in AutoPIPE
          • "Microsoft Visual C++ Runtime Library" message appears in AutoPIPE
          • "New Case Failed" Messages displayed in AutoPIPE
          • +"Note" Messages in AutoPIPE
          • +"PCFin" Messages displayed in AutoPIPE
          • +"Report Generator Error" Messages displayed in AutoPIPE
          • +"Reverse Segment" Messages displayed in AutoPIPE
          • +"SACS Export Error" messages displayed in AutoPIPE
          • +"Script Error" messages displayed in AutoPIPE
          • +"Text Node Editor" Messages displayed in when using OPIM from within AutoPIPE
          • "Unable to Import the Excel File..." Messages displayed in AutoPIPE
          • +"Warnings" Messages displayed in AutoPIPE
          • 01. "C:\Program Files (X86)\..." - Type mismatch dialog message appears when reviewing the results grids in AutoPIPE, why?
          • +Application Crashed or Freezes - AutoPIPE
          • AutoPIPE Report Viewer has stopped working
          • +Blank Messages displayed in AutoPIPE
          • +Issues that occur when exporting files from AutoPIPE
          • +Issues that occur when generating Reports from AutoPIPE
          • +Issues that occur when importing PXF files into AutoPIPE
          • +Known errors that occur when Installing / Uninstalling AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    Forrtl: severe (59): List-directed I/O syntax error , FOR$IOS_LISIO_SYN 2

    Applies To
    Product(s): AutoPIPE,
    Version(s): All
    Environment: N/A
    Area: Warning
    Original Author: Bentley Technical Support Group

    Problem:

     When importing a PXF file created by AutoPLANT or Prosteel. If the frame member ID's are not integers, the import process fails because of FORTRAN error (59) - List-directed I/O syntax error and the system AutoPIPE application crashes.

    Forrtl: severe (59): List-directed I/O syntax error , FOR$IOS_LISIO_SYN 2

    Solution:

    PXF file format is created by Bentley's AutoPLANT program. When the file is imported, AutoPIPE looks at the different map files to determine the correct format of the selected PXF file.

    Recommend the following procedure:

    1. Started AutoPIPE, File >Open > selected file, received error 59 message.

    2.  Researched message, 59  severe (59): List-directed I/O syntax error , FOR$IOS_LISIO_SYN 2. The data in a list-directed input record had an invalid format, or the type of the constant was incompatible with the corresponding variable. The value of the variable was unchanged.

    3. Looked at input file in notepad. Noticed that the file had something to do with ProSteel. AutoPlant is a piping package, therefore steel members identifications are not used or recognized by AutoPIPE import process.

    4. All occurrences of CS#1  were changed to an AutoPIPE frame member designation, ie w6x25

    5. All occurrences of Mb# were remove but leaving the number.

    6. Item 4118 is the beta angle of the steel and should have been set to 0, unless this was intentional.

    7.  Open new PXF file in AutoPIPE. 

    The following has been logged for a future version of AutoPIPE: CAE-TR-7084, Cannot import PXF file if the frame member ID's are not integers.

    See Also

    Visual Fortran run-time error messages

    Bentley AutoPIPE

    • forrtl:severe
    • severe (59)
    • Visual Fortran Run-time Error
    • AutoPIPE
    • 59
    • warning
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Wed, Oct 23 2013 10:32 AM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Wed, Apr 3 2019 11:38 AM
    • Revisions: 9
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies