You are currently reviewing an older revision of this page.
The following is displayed in when trying to analyze a model model or look at model results:
W831-11: Seismic level includes cases not analyzed
Why and how to avoid it?
This warning message is displayed whenever load case(s) used in code combinations have not been analyzed. In such cases, re-analyze the model.
Sometimes the following is displayed when trying to analyze a non-linear analysis:
---------------------------Confirm--------------------------- The load case did not converge. Do you wish to continue iterating? ---------------------------Yes No Cancel ---------------------------
If this does occur, again the W831-11 warning will be displayed whenever the results database is being accessed by a program command (i.e. using any Results> Grids, Output, etc.. type command).
Only resolution to this issue is to address the not converging issue. Please see the following AutoPIPE help section:
Help > Contents> Contents Tab> Reference Information> Static Analysis> Analysis Considerations> Nonlinear Analysis - Gaps, Friction and Soil Yielding Included> Failure to Converge. At the end of the page is 4 possible solutions to dealing with non-converging issues. There is no other solutions to this warning.
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article tothe "Comments" area below. THANK YOU!