Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki "Microsoft Visual C++ Runtime Library" message appears in AutoPIPE
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • -.Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • -Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
          • "1 Interrupted Action" messages displayed while coping AutoPIPE file, why?
          • +"Alert" Messages displayed in AutoPIPE
          • +"AutoPIPE Licensing" Messages displayed in AutoPIPE
          • +"Autopipe.exe" Messages displayed in AutoPIPE
          • +"Beam Section" Messages displayed in AutoPIPE
          • +"Bentley AutoPIPE" Messages displayed in AutoPIPE
          • +"Bentley Systems, Inc" Messages displayed in AutoPIPE
          • "Bentley.lictransmit for Windows has stopped working" message appears when using AutoPIPE program, why?
          • +"Blank" Messages displayed in AutoPIPE
          • +"Bolts*" Messages displayed in AutoPIPE
          • +"Confirm" Messages displayed in AutoPIPE
          • +"Error" messages displayed in AutoPIPE
          • +"Flange*" Messages displayed in AutoPIPE
          • +"Incorrect Data" messages displayed in AutoPIPE
          • +"Intel(r) Visual Fortran run-time error" messages displayed in AutoPIPE
          • +"Invalid Format" messages displayed in AutoPIPE
          • +"License Management Tool" Messages displayed in AutoPIPE
          • "Message from SofTrack" Messages displayed in AutoPIPE
          • +"Microsoft .NET Framework".. messages displayed in AutoPIPE
          • "Microsoft Visual C++ Runtime Library" message appears in AutoPIPE
          • "New Case Failed" Messages displayed in AutoPIPE
          • +"Note" Messages in AutoPIPE
          • +"PCFin" Messages displayed in AutoPIPE
          • +"Report Generator Error" Messages displayed in AutoPIPE
          • +"Reverse Segment" Messages displayed in AutoPIPE
          • +"SACS Export Error" messages displayed in AutoPIPE
          • +"Script Error" messages displayed in AutoPIPE
          • +"Text Node Editor" Messages displayed in when using OPIM from within AutoPIPE
          • "Unable to Import the Excel File..." Messages displayed in AutoPIPE
          • +"Warnings" Messages displayed in AutoPIPE
          • 01. "C:\Program Files (X86)\..." - Type mismatch dialog message appears when reviewing the results grids in AutoPIPE, why?
          • +Application Crashed or Freezes - AutoPIPE
          • AutoPIPE Report Viewer has stopped working
          • +Blank Messages displayed in AutoPIPE
          • +Issues that occur when exporting files from AutoPIPE
          • +Issues that occur when generating Reports from AutoPIPE
          • +Issues that occur when importing PXF files into AutoPIPE
          • +Known errors that occur when Installing / Uninstalling AutoPIPE
      • +.Bentley AutoPIPE Vessel (powered by Microprotol)
      • +ADL PIPE
      • +Bentley AutoPIPE Nozzle
      • +Bentley PlantFLOW
      • +Bentley PULS
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    "Microsoft Visual C++ Runtime Library" message appears in AutoPIPE

    Applies To
    Product(s): AutoPIPE,
    Version(s): All
    Area: Crashed
    Original Author: Bentley Technical Support Group

    Problem:

    When starting AutoPIPE or saving stress iso , the following appears:

    ---------------------------
    Microsoft Visual C++ Runtime Library
    ---------------------------
    Runtime Error!

    Program: C:\Bentley\AutoPIPE V8i SELECTseries5\autopipe.exe


    This application has requested the Runtime to terminate it in an unusual way.
    Please contact the application's support team for more information.

    ---------------------------
    OK
    ---------------------------

    Solution:

     There is very little that can be done with a model that has this error message displayed on start-up. The only options are:

    Known issue:

    #1: During a Copy / Past procedure involving segments with Distributed Weight in AutoPIPE 09.06.00.xx or lower. 

    #2:  Incorrect pipe properties were set for sequential node points (ex. points AG05 and AG06).

    #3: Error only appears after a number of attempts to create a stress iso.

    #4: Error is related to corrupted Model database.

    Avoidance:

    General Solutions

    1. Revert back to a previous version of the model DAT file that did not have a problem when being opened by the application.  

    2. Open the folder location, locate the *.BAK file, copy it to another folder location, change the file extension from BAK to DAT and try to open this new file with AutoPIPE.

    3. Start AutoPIPE, create a new model with the same General Model options settings, select File> Insert model> AutoPIPE model (*.dat), Hint: Select the option "Use Actual Coordinates" to paste using real world coordinates. 7 out of 10 times this will rescue the model geometry. However, the model Temperature / Pressure data and other minor changes will need to be re-applied. Inspect the entire model before use in production.  

    5. Use AutoPIPE File> Save As command to save back to a previous version, and then reopened that older file format in the newer version. This process of saving back to a previous version will fix the model database.

    6. See round tripping a model technique here. 

    7. Log a service ticket, attach a ZIP file containing the entire folder contents where the model is stored and see if the CAE development team can repair the model. Be sure to include any and all information that was performed in the model before this issue occurred.

    Known Issue #1 affected models:

    1. For Known Issue #1: update to AutoPIPE V8i 09.06.01.10 or higher. continue working in the newer version 

    See Also

    Warnings, Errors, Crashed, Confirm Messages in AutoPIPE

    Bentley AutoPIPE

    411079

    702587

    • AutoPIPE
    • runtime
    • message
    • crashed
    • Microsoft Visual C++ Runtime Library
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Thu, Apr 3 2014 2:06 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Fri, Jun 19 2020 9:17 AM
    • Revisions: 15
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies