Error Code 032768 - Program has encountered an error and will close now
Error Code 25 - Insufficient strength in shell/channel joint
Error Code 27 - Longitudinal membrane stress in the tubes exceeded
Error Code 28 - Longitudinal membrane stress in the shell exceeded
Error Code 29 - Equivalent stress in the tubes exceeded
Error Code 52 - WRC 107-297: Local Load Error
Error Code 89 - Allowable stress at temperature missing (95C)
Error Code 98 - Unable to design geometrical plate layout without interference
Error Code 151 - Design Code required isn't part of your license (ASME)
Error Code 181 - Cone 3: should be placed between 2 shells
Error Code 182 - No face detail on flange with gasket on both side of the bolt circle
Error Code 235, 236, 237 - Floating Head (split ring): allowable stress
Error Code 287 - Error in formula [40*bd] for gasket according to AD B7
Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundariesError Code 334 - Tubesheet: Design code required ins't part of your License (ASME)
Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended
Error Code 404 - Flange xx.xx seating pressure less than or equal to zero
Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing
Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained
Error Code 593 - Saddle effective angle < 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel
Error Code 633 - The tube-to-Tubesheet joint strength is not adequate
Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))
Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger
Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)
Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel
IDispatch::Invoke("LoadArx"=00000013) failed w/err 0x80020009
Not a valid Material Database
Unknown Procal Release - Release 1
Bentley AutoPIPE Vessel