Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
AutoPIPE
AutoPIPE Wiki
Error Messages
Sign In
-
Pipe and Vessel Stress Analysis - Wiki
+
.Bentley AutoPIPE
-
.Bentley AutoPIPE Vessel (powered by Microprotol)
+
Features and Bugs
+
General Information
+
Support Solutions and FAQ's
-
System Messages
+
"AutoPIPE Licensing" Messages displayed in AutoPIPE Vessel
+
Application Crash Messages
+
AutoPIPE Vessel Messages
+
Design and Calculations Messages
-
Error Messages
"Null IDispatch passed to AutoWrap" and "AutoCAD 2021 not registered properly" message appears when trying to generate an AutoCAD drawing using AutoPIPE, why?
Error - How to resolve "Output results required" error in AutoPIPE vessel?
Error - How to resolve "Timeout Exceeded (3600 s)" error in AutoPIPE vessel?
Error Code 032768 - Program has encountered an error and will close now
Error Code 113 - Tubesheet: modulus of elasticity at temperature missing (330 °C).... message appears in AutoPIPE AutoPIPE Vessel
Error Code 151 - Design Code required isn't part of your license (ASME)
Error Code 181 - Cone 3: should be placed between 2 shells
Error Code 182 - No face detail on flange with gasket on both side of the bolt circle
Error Code 235, 236, 237 - Floating Head (split ring): allowable stress
Error Code 243 - FLOATING HEAD (crown): modulus of elasticity at ambient temperature missing..... message appears in AutoPIPE AutoPIPE Vessel
Error Code 25 - Insufficient strength in shell/channel joint
Error Code 27 - Tubesheet Loading condition, longitudinal membrane stress
Error Code 28 - Longitudinal membrane stress in the shell exceeded
Error Code 287 - Error in formula [40*bd] for gasket according to AD B7
Error Code 29 - Equivalent stress in the tubes exceeded
Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries
Error Code 331 - NOZZLE N1: Weld sizes are not adequate
Error Code 334 - Tubesheet: Design code required ins't part of your License (ASME)
Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended
Error Code 404 - Flange xx.xx seating pressure less than or equal to zero
Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing
Error Code 417 NOZZLE xx: Insufficient reinforcement message appears when using AutoPIPE Vessel
Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained
Error Code 490 - FLAT HEAD: number of opening > 1 ==> out of the scope (the calculation has been made with the opening giving the greater thickness). Use an other code ( EN 13445-3 or BS/PD5500 ).
Error Code 515 - FLANGE 30.02 : insufficient flange thickness (design case No. 0).
Error Code 52 - WRC 107-297: Local Load Error
Error Code 538 - ADJACENT OPENINGS (nozzles C/D): nozzles are too close to one another ( 43.785 mm < 50 mm ).
Error Code 593 - Saddle effective angle < 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel
Error Code 633 - The tube-to-Tubesheet joint strength is not adequate
Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))
Error Code 773-Roof: Insufficient Rafters.
Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel
Error Code 795 - API 650: design temperature >93 deg C.
Error Code 811 -Roof: Insufficient Girders
Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger
Error Code 89 - Allowable stress at temperature missing (95C)
Error Code 98 - Unable to design geometrical plate layout without interference
Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)
Error Code-772-ROOF: Insufficient Support Column.
IDispatch::Invoke("LoadArx"=00000013) failed w/err 0x80020009
Not a valid Material Database
Unknown Procal Release - Release 1
+
Prodia2 - messages displayed in AutoPIPE Vessel
+
Prodia2.exe Messages
+
Setup Messages
+
Warning Messages
+
Video Gallery
+
ADL PIPE
+
Bentley AutoPIPE Nozzle
+
Bentley PlantFLOW
+
Bentley PULS
+
AutoPIPE Brand Learning Resources
+
Attend a live meeting with an AutoPIPE Analyst
+
Q. How to install a patch sent by Bentley AutoPIPE development team?
You are currently reviewing an older revision of this page.
History
View current version
Error Messages
Error Code 25 - Insufficient strength in shell/channel joint
Error Code 27 - Longitudinal membrane stress in the tubes exceeded
Error Code 28 - Longitudinal membrane stress in the shell exceeded
Error Code 29 - Equivalent stress in the tubes exceeded
Error Code 52 - WRC 107-297: Local Load Error
Error Code 89 - Allowable stress at temperature missing (95C)
Error Code 98 - Unable to design geometrical plate layout without interference
Error Code 151 - Design Code required isn't part of your license (ASME)
Error Code 181 - Cone 3: should be placed between 2 shells
Error Code 182 - No face detail on flange with gasket on both side of the bolt circle
Error Code 235, 236, 237 - Floating Head (split ring): allowable stress
Error Code 287 - Error in formula [40*bd] for gasket according to AD B7
Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries
Error Code 334 - Tubesheet: Design code required ins't part of your License (ASME)
Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended
Error Code 404 - Flange xx.xx seating pressure less than or equal to zero
Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing
Error Code 425
Error Code 593
Error Code 633
Error Code 677
Error Code 885
Error Code 998
Error Code 77832
See Also
Bentley AutoPIPE Vessel