<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages</link><pubDate>Mon, 21 Aug 2023 09:28:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>Tanaji Gaikwad</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Current Revision posted to AutoPIPE Wiki by Tanaji Gaikwad on 8/21/2023 9:28:28 AM&lt;br /&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/68198/error-code-113---tubesheet-modulus-of-elasticity-at-temperature-missing-330-c-message-appears-in-autopipe-autopipe-vessel"&gt;Error Code 113&amp;nbsp;-&amp;nbsp;Tubesheet: modulus of elasticity at temperature missing (330 &amp;deg;C)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;Error Code 243&amp;nbsp;- FLOATING HEAD (crown): modulus of elasticity at ambient temperature missing.&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/68284/error-code-490---flat-head-number-of-opening-1-out-of-the-scope-the-calculation-has-been-made-with-the-opening-giving-the-greater-thickness-use-an-other-code-en-13445-3-or-bs-pd5500"&gt;&lt;span style="color:#3366ff;"&gt;Error Code 490 -&amp;nbsp;FLAT HEAD: number of opening &amp;gt; 1 ==&amp;gt; out of the scope (the calculation has been made with the opening giving the greater thickness). Use an other code ( EN 13445-3 or BS/PD5500 ).&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" title="Error Code-772-ROOF: Insufficient Support Column" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66680/error-code-772-roof-insufficient-support-column"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;772 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF: Insufficient&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Support Column.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&lt;a style="color:#3366ff;" title="Error Code-773-ROOF: Insufficient Rafter" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66690/error-code-773-roof-insufficient-rafters"&gt;Error Code&amp;nbsp;773&lt;span&gt;&amp;nbsp;&lt;/span&gt;ROOF: Insufficient&amp;nbsp;Rafter.&lt;/a&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;text-decoration:underline;" title="Error Code 811 -ROOF: Insufficient Girders" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66669/error-code-811--roof-insufficient-girders"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;811 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF:&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Insufficient Girders.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/67205/error---how-to-resolve-output-results-required-error-in-autopipe-vessel"&gt;Error - How to resolve &amp;quot;Output results required&amp;quot; error in AutoPIPE vessel?&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd0"&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd1"&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/96</link><pubDate>Thu, 10 Aug 2023 18:00:24 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 96 posted to AutoPIPE Wiki by Mike Dattilio on 8/10/2023 6:00:24 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/68198/error-code-113---tubesheet-modulus-of-elasticity-at-temperature-missing-330-c-message-appears-in-autopipe-autopipe-vessel"&gt;Error Code 113&amp;nbsp;-&amp;nbsp;Tubesheet: modulus of elasticity at temperature missing (330 &amp;deg;C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Error Code 243&amp;nbsp;- FLOATING HEAD (crown): modulus of elasticity at ambient temperature missing.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" title="Error Code-772-ROOF: Insufficient Support Column" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66680/error-code-772-roof-insufficient-support-column"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;772 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF: Insufficient&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Support Column.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&lt;a style="color:#3366ff;" title="Error Code-773-ROOF: Insufficient Rafter" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66690/error-code-773-roof-insufficient-rafters"&gt;Error Code&amp;nbsp;773&lt;span&gt;&amp;nbsp;&lt;/span&gt;ROOF: Insufficient&amp;nbsp;Rafter.&lt;/a&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;text-decoration:underline;" title="Error Code 811 -ROOF: Insufficient Girders" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66669/error-code-811--roof-insufficient-girders"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;811 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF:&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Insufficient Girders.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/67205/error---how-to-resolve-output-results-required-error-in-autopipe-vessel"&gt;Error - How to resolve &amp;quot;Output results required&amp;quot; error in AutoPIPE vessel?&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd0"&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd1"&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/95</link><pubDate>Thu, 10 Aug 2023 16:15:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 95 posted to AutoPIPE Wiki by Mike Dattilio on 8/10/2023 4:15:43 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Error Code 113&amp;nbsp;-&amp;nbsp;Tubesheet: modulus of elasticity at temperature missing (330 &amp;deg;C).&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Error Code 243&amp;nbsp;- FLOATING HEAD (crown): modulus of elasticity at ambient temperature missing.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" title="Error Code-772-ROOF: Insufficient Support Column" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66680/error-code-772-roof-insufficient-support-column"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;772 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF: Insufficient&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Support Column.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&lt;a style="color:#3366ff;" title="Error Code-773-ROOF: Insufficient Rafter" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66690/error-code-773-roof-insufficient-rafters"&gt;Error Code&amp;nbsp;773&lt;span&gt;&amp;nbsp;&lt;/span&gt;ROOF: Insufficient&amp;nbsp;Rafter.&lt;/a&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;text-decoration:underline;" title="Error Code 811 -ROOF: Insufficient Girders" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66669/error-code-811--roof-insufficient-girders"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;811 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF:&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Insufficient Girders.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/67205/error---how-to-resolve-output-results-required-error-in-autopipe-vessel"&gt;Error - How to resolve &amp;quot;Output results required&amp;quot; error in AutoPIPE vessel?&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd0"&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd1"&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/94</link><pubDate>Fri, 23 Jun 2023 10:43:08 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>Tanaji Gaikwad</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 94 posted to AutoPIPE Wiki by Tanaji Gaikwad on 6/23/2023 10:43:08 AM&lt;br /&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" title="Error Code-772-ROOF: Insufficient Support Column" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66680/error-code-772-roof-insufficient-support-column"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;772 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF: Insufficient&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Support Column.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&lt;a style="color:#3366ff;" title="Error Code-773-ROOF: Insufficient Rafter" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66690/error-code-773-roof-insufficient-rafters"&gt;Error Code&amp;nbsp;773&lt;span&gt;&amp;nbsp;&lt;/span&gt;ROOF: Insufficient&amp;nbsp;Rafter.&lt;/a&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;text-decoration:underline;" title="Error Code 811 -ROOF: Insufficient Girders" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66669/error-code-811--roof-insufficient-girders"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;811 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF:&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Insufficient Girders.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/67205/error---how-to-resolve-output-results-required-error-in-autopipe-vessel"&gt;Error - How to resolve &amp;quot;Output results required&amp;quot; error in AutoPIPE vessel?&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd0"&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd1"&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/93</link><pubDate>Thu, 25 May 2023 10:29:08 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>Shrey Sharma</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 93 posted to AutoPIPE Wiki by Shrey Sharma on 5/25/2023 10:29:08 AM&lt;br /&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" title="Error Code-772-ROOF: Insufficient Support Column" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66680/error-code-772-roof-insufficient-support-column"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;772 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF: Insufficient&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Support Column.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&lt;a style="color:#3366ff;" title="Error Code-773-ROOF: Insufficient Rafter" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66690/error-code-773-roof-insufficient-rafters"&gt;Error Code&amp;nbsp;773&lt;span&gt;&amp;nbsp;&lt;/span&gt;ROOF: Insufficient&amp;nbsp;Rafter.&lt;/a&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;text-decoration:underline;" title="Error Code 811 -ROOF: Insufficient Girders" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66669/error-code-811--roof-insufficient-girders"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;811 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF:&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Insufficient Girders.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd0"&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd1"&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/92</link><pubDate>Wed, 24 May 2023 12:22:57 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>Shrey Sharma</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 92 posted to AutoPIPE Wiki by Shrey Sharma on 5/24/2023 12:22:57 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" title="Error Code-772-ROOF: Insufficient Support Column" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66680/error-code-772-roof-insufficient-support-column"&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;Error Code&amp;nbsp;772 &lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;ROOF: Insufficient&lt;/b&gt;&lt;/span&gt;&lt;span style="color:#3366ff;"&gt;&lt;b&gt;&amp;nbsp;Support Column.&lt;/b&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;text-decoration:underline;" title="Error Code 811 -ROOF: Insufficient Girders" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66669/error-code-811--roof-insufficient-girders"&gt;Error Code&amp;nbsp;811&amp;nbsp;ROOF : Insufficient Girders.&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd0"&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd1"&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/91</link><pubDate>Wed, 24 May 2023 11:46:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>Shrey Sharma</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 91 posted to AutoPIPE Wiki by Shrey Sharma on 5/24/2023 11:46:45 AM&lt;br /&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;text-decoration:underline;" title="Error Code 811 -ROOF: Insufficient Girders" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66669/error-code-811--roof-insufficient-girders"&gt;Error Code&amp;nbsp;811&amp;nbsp;ROOF : Insufficient Girders.&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd0"&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd1"&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/90</link><pubDate>Wed, 24 May 2023 11:45:18 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>Shrey Sharma</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 90 posted to AutoPIPE Wiki by Shrey Sharma on 5/24/2023 11:45:18 AM&lt;br /&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;a style="color:#3366ff;" title="Error Code 811 -ROOF: Insufficient Girders" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66669/error-code-811--roof-insufficient-girders"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Error Code&amp;nbsp;811&amp;nbsp;ROOF : Insufficient Girders.&lt;/strong&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#3366ff;"&gt;&lt;strong&gt;&lt;strong&gt;&lt;a style="color:#3366ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd0"&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd1"&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/89</link><pubDate>Wed, 24 May 2023 11:44:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>Shrey Sharma</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 89 posted to AutoPIPE Wiki by Shrey Sharma on 5/24/2023 11:44:26 AM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#0000ff;"&gt;&lt;strong&gt;&lt;a style="color:#0000ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#0000ff;"&gt;&lt;strong&gt;&lt;a style="color:#0000ff;" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#0000ff;"&gt;&lt;a style="color:#0000ff;" title="Error Code 811 -ROOF: Insufficient Girders" href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/66669/error-code-811--roof-insufficient-girders"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Error Code&lt;span&gt;&amp;nbsp;8&lt;/span&gt;&lt;span&gt;11&amp;nbsp;ROOF : Insufficient Girders.&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd0"&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1 id="mcetoc_1h16ouvgd1"&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/88</link><pubDate>Thu, 27 Aug 2020 19:35:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 88 posted to AutoPIPE Wiki by JamieP on 8/27/2020 7:35:04 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13831/idispatch-invoke-loadarx-00000013-failed-w-err-0x80020009"&gt;IDispatch::Invoke(&amp;quot;LoadArx&amp;quot;=00000013) failed w/err 0x80020009&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/87</link><pubDate>Thu, 27 Aug 2020 19:11:25 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 87 posted to AutoPIPE Wiki by JamieP on 8/27/2020 7:11:25 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38027/unknown-procal-release---release-1"&gt;Unknown Procal Release - Release 1&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/86</link><pubDate>Thu, 27 Aug 2020 18:57:52 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 86 posted to AutoPIPE Wiki by JamieP on 8/27/2020 6:57:52 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36484/not-a-valid-material-database"&gt;Not a valid Material Database&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/85</link><pubDate>Wed, 26 Aug 2020 22:03:40 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 85 posted to AutoPIPE Wiki by JamieP on 8/26/2020 10:03:40 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50569/error-code-032768---program-has-encountered-an-error-and-will-close-now"&gt;Error Code 032768 - Program has encountered an error and will close now&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/84</link><pubDate>Wed, 26 Aug 2020 21:53:53 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 84 posted to AutoPIPE Wiki by JamieP on 8/26/2020 9:53:53 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51082/error-code-677---conical-shell-xx-xx-xx-under-internal-pressure-u-2-g-analysis-is-required-or-provide-a-flare-at-the-small-junction-of-the-conical-shell-appendix-1-5-e"&gt;Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/42024/error-code-885---tubesheet-tubesheets-gasketed-with-shell-are-not-possible-for-a-fixed-tubesheets-heat-exchanger"&gt;Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/47529/error-code-998---local-loads-beyond-curve-boundaries-wrc-537-cannot-be-applied"&gt;Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32206/error-code-77832---abnormal-termination-message-appears-when-starting-autopipe-vessel"&gt;Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel&lt;/a&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/83</link><pubDate>Wed, 26 Aug 2020 21:48:01 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 83 posted to AutoPIPE Wiki by JamieP on 8/26/2020 9:48:01 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51160/error-code-633---the-tube-to-tubesheet-joint-strength-is-not-adequate"&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;&lt;strong&gt;Error Code 677&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 885&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 998&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 77832&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/82</link><pubDate>Wed, 26 Aug 2020 21:46:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 82 posted to AutoPIPE Wiki by JamieP on 8/26/2020 9:46:16 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Error Code 633 - The tube-to-Tubesheet joint strength is not adequate&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;&lt;strong&gt;Error Code 677&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 885&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 998&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 77832&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/81</link><pubDate>Wed, 26 Aug 2020 21:43:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 81 posted to AutoPIPE Wiki by JamieP on 8/26/2020 9:43:27 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38252/error-code-593---saddle-effective-angle-30deg-blast-int-max-p-corroded-inertias-corroded-weight-revise-design-of-vessel"&gt;Error Code 593 - Saddle effective angle &amp;lt; 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;h4&gt;&lt;strong&gt;Error Code 593&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 633&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 677&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 885&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 998&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 77832&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/80</link><pubDate>Wed, 26 Aug 2020 21:29:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 80 posted to AutoPIPE Wiki by JamieP on 8/26/2020 9:29:28 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;h4&gt;&lt;strong&gt;Error Code 593&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 633&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 677&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 885&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 998&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 77832&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/79</link><pubDate>Wed, 26 Aug 2020 21:28:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 79 posted to AutoPIPE Wiki by JamieP on 8/26/2020 9:28:58 PM&lt;br /&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;strong&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38756/error-code-425---floating-head-split-ring-splices-insufficient-thickness-or-gap-not-maintained"&gt;Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained&lt;/a&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;h4&gt;&lt;strong&gt;Error Code 425&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 593&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 633&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 677&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 885&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 998&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 77832&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/78</link><pubDate>Wed, 26 Aug 2020 21:21:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 78 posted to AutoPIPE Wiki by JamieP on 8/26/2020 9:21:51 PM&lt;br /&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;strong&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;strong&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;h4&gt;&lt;strong&gt;Error Code 425&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 593&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 633&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 677&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 885&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 998&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 77832&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item><item><title>Error Messages</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages/revision/77</link><pubDate>Wed, 26 Aug 2020 21:18:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80aeebeb-5102-4106-b4bc-879f72ba1b7b</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/13772/error-messages#comments</comments><description>Revision 77 posted to AutoPIPE Wiki by JamieP on 8/26/2020 9:18:59 PM&lt;br /&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18779/01-errors-while-executing-strength-calculation-for-double-fixed-tubesheet-heat-exchanger"&gt;Error Code 25 - Insufficient strength in shell/channel joint&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51156/02-error-code-27---longitudinal-membrane-stress-in-the-tubes-exceeded"&gt;Error Code 27 - Longitudinal membrane stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/51157/03-error-code-28---longitudinal-membrane-stress-in-the-shell-exceeded"&gt;Error Code 28 - Longitudinal membrane stress in the shell exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22976/04-error-code-29---equivalent-stress-in-the-tubes-exceeded"&gt;Error Code 29 - Equivalent stress in the tubes exceeded&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22415/error-code-52---wrc-107-297-local-load-error"&gt;Error Code 52 - WRC 107-297: Local Load Error&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/24031/error-code-89---allowable-stress-at-temperature-missing-95c"&gt;Error Code 89 - Allowable stress at temperature missing (95C)&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/36435/error-code-98---unable-to-design-geometrical-plate-layout-without-interference"&gt;Error Code 98 - Unable to design geometrical plate layout without interference&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38803/error-code-151---design-code-required-isn-t-part-of-your-license-asme"&gt;Error Code 151 - Design Code required isn&amp;#39;t part of your license (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32208/error-code-181---cone-3-should-be-placed-between-2-shells"&gt;Error Code 181 - Cone 3: should be placed between 2 shells&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/50421/error-code-182---no-face-detail-on-flange-with-gasket-on-both-side-of-the-bolt-circle"&gt;Error Code 182 - No face detail on flange with gasket on both side of the bolt circle&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/39068/error-code-235-236-237---floating-head-split-ring-allowable-stress"&gt;Error Code 235, 236, 237 - Floating Head (split ring): allowable stress&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38777/error-code-287---error-in-formula-40-bd-for-gasket-according-to-ad-b7"&gt;Error Code 287 - Error in formula [40*bd] for gasket according to AD B7&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/38194/error-code-316---pd-5500-figure-g-2-2-18-deflections-of-cyl-shells-due-to-radial-loads-values-beyond-curve-boundaries"&gt;Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16628/error-code-334---tubesheet-design-code-required-ins-t-part-of-your-license-asme"&gt;Error Code 334 - Tubesheet: Design code required ins&amp;#39;t part of your License (ASME)&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/48783/error-code-356---gasket-width-insufficient-minimum-mm-the-permissible-gasket-load-is-exceeded-use-of-a-compression-ring-is-recommended"&gt;Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended&lt;/a&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;h4&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/16629/error-code-404---flange-xx-xx-seating-pressure-less-than-or-equal-to-zero"&gt;Error Code 404 - Flange xx.xx seating pressure less than or equal to zero&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/32207/error-code-411-412---nozzle-ap-pad-allowable-stress-at-temp-missing-exceptional-ambient-allowable-stress-missing"&gt;Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing&lt;/a&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Error Code 425&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 593&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 633&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 677&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 885&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 998&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Error Code 77832&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/7362/bentley-autopipe-vessel-powered-by-microprotol"&gt;&lt;b&gt;Bentley AutoPIPE Vessel&lt;/b&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, error, message, Known Issues&lt;/div&gt;
</description></item></channel></rss>