You are currently reviewing an older revision of this page.
The following error message is displayed when importing a modeling into AutoPIPE:
---------------------------Error---------------------------No Piping with OD >= 1.400 inches is found in PXF file ---------------------------OK ---------------------------
How to resolve the issue?
When importing a PXF file into AutoPIPE, after selecting the General Model Options, there are a series of options available to the user on the following dialog,
If the import is successful, the following is displayed:
Select Yes to review the warning messages, the following *.MSG file are displayed:
As can be seen above, there are additional settings available that control the importing PXF file, in particular ignoring (not importing) all pipes whose Outside Diameter is less than 1.40 inches (as seen above).
These settings can be viewed / updated in the CADAP.MAP file (located int he AutoPIPE program folder). This file can be opened by any text editing application, (NotePAD, MS WORD, Ultra Edit, etc..).
First close AutoPIPE, using a text editing application, open the CADAP.MAP file for edit, scroll down to line 73, scan over the right, see the original setting = '1.40', update the value using the EXACT same format = '0.00' (see below).
Save the file, Restart AutoPIPE, and Re-import the AutoPLANT PXF file to use the new CADAP.MAP settings.
Note: Details on this file can be found in the following AutoPIPE help section:
Help > Contents> Contents Tab> Reference Information> CAD / CAE Translators> AutoPLANT to AutoPIPE> PXF Import Options
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article tothe "Comments" area below. THANK YOU!