You are currently reviewing an older revision of this page.
How can I separate the default load case (GR) to some different user load case? Because my client want to get the self-weight of pipe, the weight of insulation and the weight of lining as separated value, not total as GR load?
Answer:
This information is already tabulated in the "Center of Gravity" sub report. From the Model Listing Report dialog include the "Center of Gravity" sub report as indicated below:
Example of report
Otherwise, run multiple analysis or analysis sets turning On / Off different program features / settings, examples:
Static Analysis Set dialog:
Contents
Fluid Density Factor
Ignore friction in GR case
Pipe properties
Density
Specific gravity of contents
Insulation Density
Clad Density
Lining Density
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article tothe "Comments" area below. THANK YOU!