Logged Nov 2014, AutoPIPE V8i 09.06.01.10
The following message appears when opening a model in AutoPIPE:
---------------------------Note---------------------------N15-12: Cannot find library associated with the model---------------------------OK ---------------------------
This message appears because of the reason given, the Material library specified on the Tools> General Model Options dialog screen:
The Material file name extensions are *.Lib. When a model is opened in AutoPIPE, the program looks in for the material files in 2 locations:
1. AutoPIPE installation folder, (by default = C:\Bentley\AutoPIPE V8i SELECTseries).
2. The same folder location as the file being opened.
If the program cannot find the file referenced in the General Model Options> Material selection field, the Note message above is displayed. At this point the user has 2 options:
1. Press OK button and select a different material library from the current drop down listing.
or
2. Press OK button, close the model, and get a copy of the indicated material library file into one of the two locations mentioned above. (Note: Best Choice)
By choosing option #1 above, the newly selected material library may not have the same material or material properties as the original, best toget a copy of the original material file into one of the folder locations mentioned above. Otherwise, by selecting a different material library the user may need to update the model with custom material / data by using NS (Non-Standard) settings or one of the following methods here