10. Report option "Report determining case only" in the submenu "Report " appears to not be working


Applies To
Product(s):AutoPIPE Vessel
Version(s):V8i 
Environment: N/A
Area:
Subarea:
Original Author:Bentley Technical Support Group
Date Logged
& Current Version
Dec 2014
33.02.02.04

Problem:

We would like to inform you, that option "Report determining case only" in the submenu "Report " works incorrectly. In case of seismic load occurring to be the worst, AutoPIPE puts wind load calculation in the report instead of seismic load calculation. Please review?

Answer:

The worst case is the case for which a thickness has been increased, but in this particular user's model, the user has input the thicknesses and has selected a "Design Check" consequently there is no "governing case" and the first case has been printed out only (operation + wind). For this report, see page 135:

The option "Report determining case only" is useful with the option "Design" to know which case increased the thicknesses in last.
AutoPIPE Vessel report option is working correctly