We would like to inform you, that option "Report determining case only" in the submenu "Report " works incorrectly. In case of seismic load occurring to be the worst, AutoPIPE puts wind load calculation in the report instead of seismic load calculation. Please review?
The worst case is the case for which a thickness has been increased, but in this particular user's model, the user has input the thicknesses and has selected a "Design Check" consequently there is no "governing case" and the first case has been printed out only (operation + wind). For this report, see page 135:
The option "Report determining case only" is useful with the option "Design" to know which case increased the thicknesses in last.AutoPIPE Vessel report option is working correctly