AutoPIPE Wiki 03. Where are the factors and values that are used in a Hydrotest load case located in AutoPIPE's output (report) file
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • -Loads and Load Sets - AutoPIPE
          • 01. Animate Load cases - AutoPIPE
          • 02a. Load Case Descriptions in AutoPIPE
          • +02b. Static Analysis in AutoPIPE
          • +02c. Dynamic Analysis in AutoPIPE
          • -02e. "Hydrotest" - AutoPIPE Load Case
            • 01. Why are my V-stops not allowing lateral movement during a Hydrotest load case in AutoPIPE ?
            • 02. Is there a method to perform a Hydrotest as a non-linear analysis in AutoPIPE?
            • 03. Where are the factors and values that are used in a Hydrotest load case located in AutoPIPE's output (report) file
            • 04. Why are my Hydrotest results so high in AutoPIPE?
            • 05. How to apply the Hydrotest load and analyze it in the new version of AutoPIPE V8i 09.06.01.10?
            • 06. Why does the Hydrotest case show an Allowable K Factor of 0.9 in AutoPIPE?
            • 07. How to assign code allowable stress for hydrotest loading: hoop stress and HY stress combination in AutoPIPE?
            • 08. How to calculate the Hydrotest Hoop stress and Allowable values in AutoPIPE?
            • 10. Why is there a difference in results between the Normal Sustain load (ex. Gr+MaxP (1)) and the Hydrotest Sustain load (ex. Gr+MaxP (2)) in AutoPIPE?
            • 11. How to apply more than one hydro-test analysis sets with different settings to an AutoPIPE model?
            • 14. Why is the gravity load case results weigh more than the Hydrotest gravity load case results on a Gas pipe line modeled in AutoPIPE?
          • +02f. "Static Earthquake" - AutoPIPE Load Case
          • +02g. "Wind" - AutoPIPE Load Case
          • +02h. "Snow Load" - AutoPIPE Load Case
          • 02i. "Thermal Bowing" - AutoPIPE Load Case
          • +02k. "Response / Force Spectrum Loads" - AutoPIPE Load Case
          • +02n. "Harmonic" - AutoPIPE Load case
          • 02p. "Time History" (M1-M50) - AutoPIPE Load Case
          • 02s. "Buoyancy" - AutoPIPE Load Case
          • +02t. "Wave" - AutoPIPE Load Case
          • +02u. "Fluid Transient" - AutoPIPE Load Case
          • 02v. "Steam Relief" - AutoPIPE Load Case
          • +02w. "Thermal Transient Analysis" (TTA) - AutoPIPE Load Case
          • +03a. "Gravity" - AutoPIPE Load Case
          • +03b. "Pressure" - AutoPIPE load case
          • 03c. "Temperature" - AutoPIPE load case
          • +03d. "SAM" (Seismic Anchor Analysis) - AutoPIPE load case
          • +03e. "Fatigue" - AutoPIPE load case
          • +03f. "Xtra Data" - AutoPIPE load case
          • +03g. "Occasional" - AutoPIPE load case
          • 03h. "Distributed Load" - AutoPIPE load case
          • 04. Results From Loads and Load Sets Not Answered By Piping Code Calculations
          • +05. Combination Load Cases (Tools> Combinations dialog)
          • +06. Non-linear Load Sequencing Explained
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    03. Where are the factors and values that are used in a Hydrotest load case located in AutoPIPE's output (report) file

    Applies To
    Product(s): AutoPIPE
    Version(s): 2004, XM, V8i 
    Area: Report
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    Feb. 2015
    09.06.01.10

    Problem:

    I know that for HY calculation I must access the window Hydrotest where I select the pressure case (P1) and the multiplier (that is generally 1.5).
    I'm not able to see the value of the test pressure in output file How can see the value of test pressure in the output (report) file?
    Why the software doesn't show the value of multiplier as requested by ASME B31.3 (that is generally 1.5 Sc/Sh)?

    Solution:

    The Hydrotest parameters are printed in the "Analysis Summary" section of the output report under "Hydrotest Load"

    Temperature Load Case Factor

    Pressure load Case Factor

    Note:

    Temperature and Pressure load case values can vary from node point to node point. In some cases the values may be all the same, in other cases for each set of node points these values can be different. Therefore, AutoPIPE performs this calculation internally and prints the results in the output report. Each of the values (Press or Temp)  used for the calculations are not printed in the output report. The following enhancements have been logged:

    TFS-E237988: Report calculated hydrotest pressure in model input listing.

    See Also

    Bentley AutoPIPE

    • AutoPIPE
    • Report
    • Hydrotest
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Fri, Feb 6 2015 6:47 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Wed, Apr 17 2019 10:21 AM
    • Revisions: 8
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies