Applies To | |||
Product(s): | AutoPIPE | ||
Version(s): | 2004, XM, V8i | ||
Area: | Printing | ||
Original Author: | Bentley Technical Support Group | ||
Date Logged & Current Version | Feb. 2015 09.06.01.10 |
How to print parts of the model highlighted red color only in the AutoPIPE output report?
After analyzing a model in AutoPIPE, select the necessary node points, segments, components, etc., then click Results > Output Report > enable (check ON) "Limit results to highlighted points" (see online help for details on this option), then enable any additional sub reports you require before clicking the OK button.
Note, one can filter selection of node points / limit reporting of node points that meet a certain threshold by using AutoPIPE's Filter (Result > Filters > Filters) command. There are 5 different filter options available, select the option, and when the dialog appears, press the help button to learn more about the feature.
Example:
Only select node points where the stress is larger than a threshold setting. Press Results> Filters> Filters> Code Stress, greater than (enter a setting), press OK.
In this example, some node points and some components are highlighted red. In order for a component to be shown in red, both ends of that component must meet the filter threshold setting (C16-C15). Otherwise, if only one side of a component meets the threshold, than only that node point will be highlighted red (ex. A19, B16).