<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>21. Is it possible to specify factors on foundation loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/21087/21-is-it-possible-to-specify-factors-on-foundation-loads-in-autopipe-vessel</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>21. Is it possible to specify factors on foundation loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/21087/21-is-it-possible-to-specify-factors-on-foundation-loads-in-autopipe-vessel</link><pubDate>Tue, 25 Aug 2020 19:34:56 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d70fe23-e059-41da-bf97-e7875a65dab2</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/21087/21-is-it-possible-to-specify-factors-on-foundation-loads-in-autopipe-vessel#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/25/2020 7:34:56 PM&lt;br /&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;Answer: &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;Yes, the user can add factors on the vessel foundation load separately for the liquid content inside the vessel as well as factor on the vessel weight itself. Go to Vessel Properties&amp;gt;Load Conditions, and then enter the factors under Factor on Liquid and Factor on Weight as shown below (in the example 1.5 is used):&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/70202.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/540x0/__key/communityserver-wikis-components-files/00-00-00-00-41/70202.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;The total foundation load before applying factor as seen in the report for a horizontal vessel was 9588 daN.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/8551.2.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/640x0/__key/communityserver-wikis-components-files/00-00-00-00-41/8551.2.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;After applying 1.5 factor the foundation load is 9588 x 1.5 = 14381 daN.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/2210.3.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/600x0/__key/communityserver-wikis-components-files/00-00-00-00-41/2210.3.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, foundation load factor&lt;/div&gt;
</description></item><item><title>Q. Is it possible to specify factors on foundation loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/21087/21-is-it-possible-to-specify-factors-on-foundation-loads-in-autopipe-vessel/revision/2</link><pubDate>Wed, 06 Jan 2016 19:29:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d70fe23-e059-41da-bf97-e7875a65dab2</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/21087/21-is-it-possible-to-specify-factors-on-foundation-loads-in-autopipe-vessel#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by Mike Dattilio on 1/6/2016 7:29:58 PM&lt;br /&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;&lt;span style="font-size:150%;color:#ffffff;background-color:#008000;"&gt;Answer: &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;Yes, the user can add factors on the vessel foundation load separately for the liquid content inside the vessel as well as factor on the vessel weight itself. Go to Vessel Properties&amp;gt;Load Conditions, and then enter the factors under Factor on Liquid and Factor on Weight as shown below (in the example 1.5 is used):&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/70202.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img src="/resized-image/__size/540x0/__key/communityserver-wikis-components-files/00-00-00-00-41/70202.1.png" alt=" " /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;The total foundation load before applying factor as seen in the report for a horizontal vessel was 9588 daN.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/8551.2.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img src="/resized-image/__size/640x0/__key/communityserver-wikis-components-files/00-00-00-00-41/8551.2.png" alt=" " /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;After applying 1.5 factor the foundation load is 9588 x 1.5 = 14381 daN.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:120px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/2210.3.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img src="/resized-image/__size/600x0/__key/communityserver-wikis-components-files/00-00-00-00-41/2210.3.png" alt=" " /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AutoPIPE Vessel, foundation load factor&lt;/div&gt;
</description></item><item><title>Is it possible to specify factors on foundation loads in AutoPIPE Vessel?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/21087/21-is-it-possible-to-specify-factors-on-foundation-loads-in-autopipe-vessel/revision/1</link><pubDate>Wed, 29 Apr 2015 18:19:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d70fe23-e059-41da-bf97-e7875a65dab2</guid><dc:creator>Sudip Ganguly</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/21087/21-is-it-possible-to-specify-factors-on-foundation-loads-in-autopipe-vessel#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Sudip Ganguly on 4/29/2015 6:19:51 PM&lt;br /&gt;
&lt;p&gt;Ans: Yes, the user can add factors on the vessel foundation load separately for the liquid content inside the vessel as well as factor on the vessel weight itself. Go to Vessel Properties&amp;gt;Load Conditions, and then enter the factors under Factor on Liquid and Factor on Weight as shown below (in the example 1.5 is used):&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/70202.1.png"&gt;&lt;img src="/resized-image/__size/540x0/__key/communityserver-wikis-components-files/00-00-00-00-41/70202.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;The total foundation load before applying factor as seen in the report for a horizontal vessel was 9588 daN.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/8551.2.png"&gt;&lt;img src="/resized-image/__size/640x0/__key/communityserver-wikis-components-files/00-00-00-00-41/8551.2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;After applying 1.5 factor the foundation load is 9588 x 1.5 = 14381 daN.&lt;/p&gt;