Why does the Analysis summary report not match the Data in the model?
Example: see the model Temperature values:
However in the Analysis Summary, the temperature values are printed in the report as:
Why and how to fix?
The printed report values that are enclosed within the "< >" brackets are not temperature data from the model but rather the Load Combination Description Automatically generated / Manually entered under the Tools> Load Combinations dialog
Analysis Summary sub report issues:
Bentley AutoPIPE