Why does AutoPIPE issue a warning that a general command is issued, (example, segment show is toggled). This is just a change in view, not in the model analysis or results. Is there a way to turn this warning off?
---------------------------Confirm--------------------------- Current model revision does not match analysis result(s) below: * Static * Modal To avoid having this message again, you will need to re-run or delete all the above analysis results. Do you want to delete them now?---------------------------Yes No Cancel ---------------------------
Any changes to the model database will cause the message above to appear. Example, shutting off the segments for part of the model is viewed as a change to the database, because now the results are filtered on the still visible node points. This is a model revision change and thus the waning is displayed. There is no feature to turn off this confirmation. It is only meant to notify the user that the model revision has been updated, you can choose to ignore it or as suggested, delete analysis results, and re-run analysis before viewing / printing results.
Bentley AutoPIPE