Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 01. What is the difference between the support and the restraint output reports in AutoPIPE?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • -.Bentley AutoPIPE
        • +a. General Information about AutoPIPE
        • +b. NEW User Guide for AutoPIPE
        • +c. Technical Support - AutoPIPE
        • +d. Download - Install - Release Notes - AutoPIPE
        • +e. Features and Bugs in AutoPIPE
        • +f. License AutoPIPE -
        • +g. System Messages: Warnings, Errors, Crashed, Confirm, etc.. in AutoPIPE
        • h. QA&R program for AutoPIPE
        • i. Security
        • -❤︎ Support Solutions and FAQ's in AutoPIPE
          • +Batch Processing, ITS, and ATS using AutoPIPE
          • +File / Model Management using AutoPIPE
          • +General - AutoPIPE
          • +Graphics - AutoPIPE
          • +Grids (Input & Results) - AutoPIPE
          • +Import and Export - AutoPIPE
          • +Libraries - AutoPIPE
          • +Loads and Load Sets - AutoPIPE
          • +Localization (Non-English Language) - AutoPIPE
          • +Modeling Approaches in AutoPIPE
          • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
          • +Piping codes - AutoPIPE
          • +Post Processing - AutoPIPE
          • +Printing - AutoPIPE
          • -Reports - AutoPIPE
            • +01. Reports - Results Interpretation in AutoPIPE
            • -02. Analysis Sub-reports FAQ in AutoPIPE
              • +"Acceleration" sub-report using Results> Output Report in AutoPIPE
              • +"Analysis summary" sub-report using Results> Output Report in AutoPIPE
              • +"Code Compliance" sub-report using Results> Output Report in AutoPIPE
              • "Cumulative Usage Report" sub report using Results> Output Report in AutoPIPE
              • +"Displacement" sub report using Results> Output Report in AutoPIPE
              • +"Equipment" sub report using Results> Output Report in AutoPIPE
              • +"Flange Summary" sub-report results using AutoPIPE
              • +"Forces & Moments" sub-report using Results> Output Report in AutoPIPE
              • +"Frequencies" sub-report using Results> Output Report in AutoPIPE
              • +"General Stress" sub-report using Results> Output Report in AutoPIPE
              • +"Mode Shape" sub report using Results> Output Report in AutoPIPE
              • +"Preliminary Stress" sub-report using Results> Output Report in AutoPIPE
              • +"Reference Point Loads" sub-report using Results> Output Report in AutoPIPE
              • +"Restraint" Sub-report of the Output Report in AutoPIPE
              • +"Result Summary" sub-report using Results> Output Report in AutoPIPE
              • +"Soil" sub report using Results> Output Report in AutoPIPE
              • +"Stress Indices" sub-report using Results> Output Report in AutoPIPE
              • +"Stress Summary" sub-report using Results> Output Report in AutoPIPE
              • -"Support" sub report using Results> Output Report in AutoPIPE
                • 01. What is the difference between the support and the restraint output reports in AutoPIPE?
                • 02. Why are Membrane or Local stresses from pipe supports not included in AutoPIPE?
                • 03. During animation of load-case in AutoPIPE, pipe support moved with pipe freely without any opposition, why?
                • 04. Support report indicates a load on a support who's open gaps never closed during an AutoPIPE Analysis, so why is there a load on the support in open gap direction?
                • 05. Support results on a vertical support in an AutoPIPE model does not change, regardless of "Weight of Contents" settings. Appears Weight of Contents is not considered in my model, how to verify?
                • 06. AutoPIPE FAQ Question 116: Why are membrane stresses from pipe support not included in AutoPIPE?
                • 07. AutoPIPE's Support sub-report results indicate little to no displacement at a Support that has large gaps all around, WHY?
                • 09. Support forces for Occasional load (i.e. Earthquake) are not evenly distributed among multiple supports in AutoPIPE model, why?
                • 10. How are a support's axial force due to xxx load case calculated in AutoPIPE's reports?
                • 11. Pipe displacement decreases as gap size increases in AutoPIPE, why?
                • 11. Support forces = 0.00 in AutoPIPE's results, why?
                • 12. Support Forces Report, why do local support forces on a global axis not match global forces in AutoPIPE's output report?
                • 13. Why are spring or rigid hangers on vertical legs showing large reaction loads in the Hydrotest load set case for AutoPIPE's reports?
              • +a. "Flange Analysis" sub-report in AutoPIPE
              • +b. "Spring Hanger analysis" sub report using Analyze> Spring Hanger> Print Report command in AutoPIPE
              • +_AutoPIPE's Output report Cover and Title page
            • +03. Component Data Listing (Model Input Listing) FAQ in AutoPIPE
            • +04. Report Manager reports FAQ in AutoPIPE
            • +05. Typical Comments, Questions, and Answers about AutoPIPE's Reports
          • +Settings - AutoPIPE
          • +Stress Isometrics - AutoPIPE
          • +Technology Productivity Capabilities
      • +.Bentley AutoPIPE Vessel (powered by Microprotol)
      • +ADL PIPE
      • +Bentley AutoPIPE Nozzle
      • +Bentley PlantFLOW
      • +Bentley PULS
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    01. What is the difference between the support and the restraint output reports in AutoPIPE?

    Applies To
    Product(s): AutoPIPE
    Version(s): 2004, XM, V8i 
    Area: Report
    Original Author: Bentley Technical Support Group
    Date Logged
    & Current Version
    June 2015
    09.06.02.06

    Problem:

    What is the difference between the support and the restraint output reports? There seems to be some overlap

    Solution:

    For last 21 years  AutoPIPE has had a Support and Restraint output report (yes there is some overlap), The Restraint report is the piping loads on supports and Anchors shown in Global axis system  where as the Support forces report shows only piping loads on Supports but includes both local and global force/moments and displacements.

    Note, there is only support report on the StressISO which finds maximum loads from whichever non-code combination(s) is selected.

    To watch the on-demand webinar "Maximizing AutoPIPE Standard and Custom Reporting Capabilities", click here.

    See Also

    "Support" sub report using Results> Output Report in AutoPIPE

    Bentley AutoPIPE

    • AutoPIPE
    • Restraint
    • support
    • Report
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Tue, Jun 9 2015 5:49 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Tue, Feb 22 2022 12:36 PM
    • Revisions: 7
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies