<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>02. Does AutoPIPE Vessel consider cone-shell junction as line of support for external pressure calculation?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>02. Does AutoPIPE Vessel consider cone-shell junction as line of support for external pressure calculation?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation</link><pubDate>Tue, 25 Aug 2020 19:53:12 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4e267cda-3a50-4751-8f97-856b31109ace</guid><dc:creator>JamieP</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation#comments</comments><description>Current Revision posted to AutoPIPE Wiki by JamieP on 8/25/2020 7:53:12 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;Answer: &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Yes, AutoPIPE Vessel automatically considers the cone-shell junction as line of support for external pressure calculations.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;If the junction is not sufficient then a stiffener is automatically added.&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#008000;"&gt;This is clearly printed out in the report (see &amp;ldquo;External pressure&amp;rdquo; + &amp;ldquo;conical junction&amp;rdquo;).&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Observe the vertical vessel with a conical transition section at the middle. The stiffener has been automatically added.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The design report shows inclusion of cone-shell junction as line of support for external pressure calculations.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Also Appendix 1-8 calculations performed to check the design for external pressure for conical shell:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: stiffener, AutoPIPE Vessel, external pressure, line of support, cone shell junction&lt;/div&gt;
</description></item><item><title>Q. Does AutoPIPE Vessel consider cone-shell junction as line of support for external pressure calculation?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation/revision/5</link><pubDate>Wed, 26 Jun 2019 00:35:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4e267cda-3a50-4751-8f97-856b31109ace</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation#comments</comments><description>Revision 5 posted to AutoPIPE Wiki by Mike Dattilio on 6/26/2019 12:35:15 AM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;Answer: &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Yes, AutoPIPE Vessel automatically considers the cone-shell junction as line of support for external pressure calculations.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;If the junction is not sufficient then a stiffener is automatically added.&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#008000;"&gt;This is clearly printed out in the report (see &amp;ldquo;External pressure&amp;rdquo; + &amp;ldquo;conical junction&amp;rdquo;).&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Observe the vertical vessel with a conical transition section at the middle. The stiffener has been automatically added.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The design report shows inclusion of cone-shell junction as line of support for external pressure calculations.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Also Appendix 1-8 calculations performed to check the design for external pressure for conical shell:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: stiffener, AutoPIPE Vessel, external pressure, line of support, cone shell junction&lt;/div&gt;
</description></item><item><title>08. Does AutoPIPE Vessel consider cone-shell junction as line of support for external pressure calculation?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation/revision/4</link><pubDate>Wed, 06 Jan 2016 18:55:52 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4e267cda-3a50-4751-8f97-856b31109ace</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation#comments</comments><description>Revision 4 posted to AutoPIPE Wiki by Mike Dattilio on 1/6/2016 6:55:52 PM&lt;br /&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:150%;color:#ffffff;background-color:#008000;"&gt;Answer: &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Yes, AutoPIPE Vessel automatically considers the cone-shell junction as line of support for external pressure calculations.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;If the junction is not sufficient then a stiffener is automatically added.&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#008000;"&gt;This is clearly printed out in the report (see &amp;ldquo;External pressure&amp;rdquo; + &amp;ldquo;conical junction&amp;rdquo;).&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Observe the vertical vessel with a conical transition section at the middle. The stiffener has been automatically added.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;The design report shows inclusion of cone-shell junction as line of support for external pressure calculations.&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="color:#008000;"&gt;Also Appendix 1-8 calculations performed to check the design for external pressure for conical shell:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;span style="color:#008000;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png"&gt;&lt;span style="color:#008000;"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: stiffener, AutoPIPE Vessel, external pressure, line of support, cone shell junction&lt;/div&gt;
</description></item><item><title>08. Does AutoPIPE Vessel consider cone-shell junction as line of support for external pressure calculation?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation/revision/3</link><pubDate>Tue, 05 Jan 2016 20:16:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4e267cda-3a50-4751-8f97-856b31109ace</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation#comments</comments><description>Revision 3 posted to AutoPIPE Wiki by Mike Dattilio on 1/5/2016 8:16:39 PM&lt;br /&gt;
&lt;p&gt;Ans: Yes, AutoPIPE Vessel automatically considers the cone-shell junction as line of support for external pressure calculations.&lt;/p&gt;
&lt;p&gt;If the junction is not sufficient then a stiffener is automatically added.&lt;br /&gt;This is clearly printed out in the report (see &amp;ldquo;External pressure&amp;rdquo; + &amp;ldquo;conical junction&amp;rdquo;).&lt;/p&gt;
&lt;p&gt;Observe the vertical vessel with a conical transition section at the middle. The stiffener has been automatically added.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;The design report shows inclusion of cone-shell junction as line of support for external pressure calculations.&lt;/p&gt;
&lt;p&gt;Also Appendix 1-8 calculations performed to check the design for external pressure for conical shell:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: stiffener, AutoPIPE Vessel, external pressure, line of support, cone shell junction&lt;/div&gt;
</description></item><item><title>Does AutoPIPE Vessel consider cone-shell junction as line of support for external pressure calculation?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation/revision/2</link><pubDate>Wed, 05 Aug 2015 17:59:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4e267cda-3a50-4751-8f97-856b31109ace</guid><dc:creator>Sudip Ganguly</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by Sudip Ganguly on 8/5/2015 5:59:39 PM&lt;br /&gt;
&lt;p&gt;Ans: Yes, AutoPIPE Vessel automatically considers the cone-shell junction as line of support for external pressure calculations.&lt;/p&gt;
&lt;p&gt;If the junction is not sufficient then a stiffener is automatically added.&lt;br /&gt;This is clearly printed out in the report (see &amp;ldquo;External pressure&amp;rdquo; + &amp;ldquo;conical junction&amp;rdquo;).&lt;/p&gt;
&lt;p&gt;Observe the vertical vessel with a conical transition section at the middle. The stiffener has been automatically added.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;The design report shows inclusion of cone-shell junction as line of support for external pressure calculations.&lt;/p&gt;
&lt;p&gt;Also Appendix 1-8 calculations performed to check the design for external pressure for conical shell:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png"&gt;&lt;img alt=" " src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: stiffener, AutoPIPE Vessel, external pressure, line of support, cone shell junction&lt;/div&gt;
</description></item><item><title>Does AutoPIPE Vessel consider cone-shell junction as line of support for external pressure calculation?</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation/revision/1</link><pubDate>Wed, 05 Aug 2015 17:58:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4e267cda-3a50-4751-8f97-856b31109ace</guid><dc:creator>Sudip Ganguly</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/22996/02-does-autopipe-vessel-consider-cone-shell-junction-as-line-of-support-for-external-pressure-calculation#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Sudip Ganguly on 8/5/2015 5:58:32 PM&lt;br /&gt;
&lt;p&gt;Ans: Yes, AutoPIPE Vessel automatically considers the cone-shell junction as line of support for external pressure calculations.&lt;/p&gt;
&lt;p&gt;If the junction is not sufficient then a stiffener is automatically added.&lt;br /&gt;This is clearly printed out in the report (see &amp;ldquo;External pressure&amp;rdquo; + &amp;ldquo;conical junction&amp;rdquo;).&lt;/p&gt;
&lt;p&gt;Observe the vertical vessel with a conical transition section at the middle. The stiffener has been automatically added.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/5758.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;The design report shows inclusion of cone-shell junction as lien of support for external pressure calculations.&lt;/p&gt;
&lt;p&gt;Also Appendix 1-8 calculations performed to check the design for external pressure for conical shell:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png"&gt;&lt;img src="/resized-image/__size/720x0/__key/communityserver-wikis-components-files/00-00-00-00-41/72720.2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: stiffener, AutoPIPE Vessel, external pressure, line of support, cone shell junction&lt;/div&gt;